Standard Method of Test for Effective Series Resistance (ESR) and Capacitance of Multilayer Ceramic Capacitors at High Frequencies Editorially Corrected - February 1982
This method provides procedures for the measurement of effective series resistance
(esr) and capacitance of multilayer ceramic capacitors from frequencies of 25 MHz to 1.25 GHz. A series connection permits the measurement of capacitance from below 1 pF t