Automatic electric controls for household and similar use - Part 2-19: Particular requirements for electrically operated oil valves, including mechanical requirements
1.1 This part 2 of IEC 60730 applies to electrically operated oil valves for use in, on or in
association with equipment for household and similar use that use electricity, in combination
with fuel in the liquid state such as distillates, residual fuels, etc.
This part 2 also applies to electrically operated oil valves using NTC or PTC thermistors,
requirements for which are contained in annex J.
1.1.1 This standard applies to the inherent safety, to the operating values, operating times,
and operating sequences where such are associated with equipment safety, and to the testing
of electrically operated oil valves used in, or in association with, household or similar
equipment, but also extended to industrial purposes where no dedicated product standard
exists, such as that for central heating, air conditioning, process heating, etc.
This part 2 is also applicable to controls for appliances within the scope of IEC 60335-1.
Throughout this part 2 the word "equipment" means "appliance and equipment".
This part 2 does not apply to electrically operated oil valves designed exclusively for industrial
applications.
Electrically operated oil valves for equipment not intended for normal household use, but which
nevertheless may be used by the public, such as equipment intended to be used by laymen in
shops, in light industry and on farms, are within the scope of this part 2.
This part 2 identifies a number of mechanical features as "under consideration". Until these
mechanical requirements are incorporated in this part 2, each country using this part 2 will
have to quantify these requirements.
Compliance of an electrically operated oil valve with this part 2 does not imply that the valve is acceptable without
further tests for these mechanical features.
1.1.2 This part 2 applies to manual controls when such are electrically and/or mechanically
integral with electrically operated oil valves.
Requirements for manual switches not forming part of an electrically operated oil valve are contained in
IEC 61058-1.
This part 2 does not apply to electrically operated oil valves of nominal connection size above
DN 150.
Hereinafter, the term "valve" is used to denote an electrically operated oil valve (including
prime mover and valve body).
1.1.3 An electric actuator that is submitted to the testing laboratory in combination with an oil
valve will be evaluated under this part 2. A separate electric actuator is evaluated under
IEC 60730-2-14, which provides particular requirements for electric actuators.
1.1.4 This part 2 also applies to valves utilized as part of a system, or valves mechanically
integral with multifunctional controls.