TIA TSB-143-2007
光纤功率仪:测试和应用问题

Fiber Optic Power Meters: Measurement and Application Issues


TIA TSB-143-2007




购买全文,请联系:


标准号
TIA TSB-143-2007
发布
2007年
发布单位
美国电信工业协会
 
 
适用范围
The proper calibration of an optical power meter requires the verification of two critical parameters: absolute accuracy at a given reference power over a wavelength range and linearity at a given wavelength over a power range. We discuss the key elements involved in determining the uncertainty in the absolute accuracy and the non-linearity of the power response under what are termed “reference conditions of calibration”. We also discuss the underlying causes of erroneous measurements resulting from each of the three subsystems constituting a power meter: detector element, collecting optics and electronics.