IEC 61158-4-7:2007
工业通讯网络.数据总线规范.第4-7部分:数据联络层协议规范.7型元件

Industrial communication networks - Fieldbus specifications - Part 4-7: Data-link layer protocol specification - Type 7 elements


标准号
IEC 61158-4-7:2007
发布
2007年
发布单位
国际电工委员会
替代标准
IEC 61158-4-7:2007/COR1:2014
当前最新
IEC 61158-4-7:2007/COR1:2014
 
 
引用标准
IEC 61158-2 IEC 61158-3-7 ISO/IEC 10731 ISO/IEC 7498-1 ISO/IEC 7498-3
被代替标准
IEC 65C/474/FDIS:2007 IEC 61158-4:2003
适用范围
1.1 General The data-link layer provides basic time-critical messaging communications between devices in an automation environment. This protocol provides communication opportunities to all participating data-link entities a) in a synchronously-starting cyclic manner, according to a pre-established schedule, and b) in a cyclic or acyclic asynchronous manner, as requested each cycle by each of those data-link entities. Thus this protocol can be characterized as one which provides cyclic and acyclic access asynchronously but with a synchronous restart of each cycle. 1.2 Specifications This standard specifies a) procedures for the timely transfer of data and control information from one data-link user entity to a peer user entity, and among the data-link entities forming the distributed datalink service provider; b) the structure of the fieldbus DLPDUs used for the transfer of data and control information by the protocol of this standard, and their representation as physical interface data units. 1.3 Procedures The procedures are defined in terms of a) the interactions between peer DL-entities (DLEs) through the exchange of fieldbus DLPDUs; b) the interactions between a DL-service (DLS) provider and a DLS-user in the same system through the exchange of DLS primitives; c) the interactions between a DLS-provider and a Ph-service provider in the same system through the exchange of Ph-service primitives. 1.4 Applicability These procedures are applicable to instances of communication between systems which support time-critical communications services within the data-link layer of the OSI or fieldbus reference models, and which require the ability to interconnect in an open systems interconnection environment. Profiles provide a simple multi-attribute means of summarizing an implementation’s capabilities, and thus its applicability to various time-critical communications needs. 1.5 Conformance This standard also specifies conformance requirements for systems implementing these procedures. This part of this standard does not contain tests to demonstrate compliance with such requirements.

IEC 61158-4-7:2007相似标准


推荐

融入现场总线技术的DCS在火电厂的应用研究

在EMG电动阀内部具有1个跳线,用于选择屏蔽是否接地,对于Profibus-DP总线多点接地的要求,必须将该跳线置于屏蔽与地Close位置,这样才能保证良好接地。   (10)通信协议转换现场部分设备采用Mod-bus通信方式,为了实现全厂统一的Profibus节点,采用了Modbus转换Profibus的转换模块(总线桥),并将其接入FCS165控制系统。...

9大现场总线全解析,赶紧收藏!

它采用了OSI模型的物理数据链路层,由这两部分形成了其标准第一部分的子集,DP隐去了3~7,而增加了直接数据连接拟合作为用户接口,FMS只隐去3~6,采用了应用,作为标准的第二部分。PA的标准目前还处于制定过程之中,其传输技术遵从IEC1158-2(1)标准,可实现总线供电与本质安全防爆。四、CAN总线控制器局域网(CAN)最早由Bosch公司于1985年研发,用于搭建车内网络。...

九大现场总线,你知道几个?会用几个?

它采用了OSI模型的物理数据链路层,由这两部分形成了其标准第一部分的子集,DP隐去了3~7,而增加了直接数据连接拟合作为用户接口,FMS只隐去3~6,采用了应用,作为标准的第二部分。PA的标准目前还处于制定过程之中,其传输技术遵从IEC1158-2(1)标准,可实现总线供电与本质安全防爆。四、CAN总线控制器局域网(CAN)最早由Bosch公司于1985年研发,用于搭建车内网络。...

九大最流行现场总线“叱咤”工控领域

它采用了OSI模型的物理数据链路层,由这两部分形成了其标准第一部分的子集,DP隐去了3~7,而增加了直接数据连接拟合作为用户接口,FMS只隐去3~6,采用了应用,作为标准的第二部分。PA的标准目前还处于制定过程之中,其传输技术遵从IEC1158-2(1)标准,可实现总线供电与本质安全防爆。Porfibus支持主—从系统、纯主站系统、多主多从混合系统等几种传输方式。...