IEC 61326-3-2:2008
测量、控制和实验室用电气设备.电磁兼容性(EMC)的要求.第3-2部分:与安全相关的系统和用于与执行安全相关的功能设备(功能安全)用抗扰度要求.带指定电磁环境的工业设施

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety related functions (functional safety) - Industrial applications w


标准号
IEC 61326-3-2:2008
发布
2008年
发布单位
国际电工委员会
替代标准
IEC 61326-3-2:2008/ISH1:2013
当前最新
IEC 61326-3-2:2017 RLV
 
 
引用标准
IEC 60050-161 IEC 61000-4-11:2004 IEC 61000-4-29:2000 IEC 61000-4-2:2001 IEC 61000-4-3:2006 IEC 61000-4-4:2004 IEC 61000-4-5:2005 IEC 61000-4-6:2004 IEC 61000-4-8:1993 IEC 61000-6-2:2005 IEC 61326-1:2005 IEC 61326-2-1:2005 IEC 61326-2-2:2005 IEC 61326-2-3
被代替标准
IEC 65A/501/FDIS:2007 IEC 61326:2002 IEC 61326 Corrigendum 1:2002
适用范围
The scope of IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as they can be found in industrial applications with an electromagnetic environment having specified characteristics (for example, process industry). The difference between the electromagnetic environment covered by this standard compared to the general industrial environment (see IEC 61326-3-1) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment. The environment of industrial application with a specified electromagnetic environment typically includes the following characteristics: – industrial area with limited access; – limited use of mobile transmitter; – dedicated cables for power supply and control, signal or communication lines; – separation between power supply and control, signal or communication cables; – factory building mostly consisting of metal construction; – overvoltage/lightning protection by appropriate measures (for example, metal construction of the building or use of protection devices); – pipe heating systems driven by a.c. main power may be present; – no high-voltage substation close to sensitive areas; – presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with low power; – competent staff; – periodical maintenance of equipment and systems; – mounting and installation guidelines for equipment and systems. A more detailed description of the above-mentioned typical characteristics is given in Annex B. Equipment and systems considered as “proven-in-use” according to IEC 61508 or IEC 61511 are excluded from the scope of IEC 61326-3-2. Fire alarm systems and security alarm systems intended for protection of buildings are excluded from the scope of IEC 61326-3-2.

谁引用了IEC 61326-3-2:2008 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号