Insert front surface shall be flat within .005 T.I.R.
Dimensions are in inches.
The point at which a gage pin, having the same basic diameter as the mating contact and a square face, touches socket contact spring.
Normal keyway position. For other keyway positions see MIL-DTL-38999.
Diameters A and D shall be concentric within .015 T.I.R.Diameter A with respect to diameter B, and diameter D with respect to diameter N, shall be
concentric at MMC.Diameters D and I shall be concentric within .015 T.I.R at MMC.The gauge features for GG shall be CC smaller than their MMC size at basic location.The gauge features for GG shall be .010 smaller than their MMC size at basic location.