ISO/ASTM 52116-2002
自带的干式存储γ射线辐照器的剂量测定实施规范

Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:ISO/ASTM 52116-2002 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

ISO/ASTM 52116-2002



标准号
ISO/ASTM 52116-2002
发布日期
2002年12月
实施日期
废止日期
中国标准分类号
F80
国际标准分类号
17.240
发布单位
国际标准化组织
代替标准
ISO/ASTM 52116-2013
适用范围
1 This practice outlines dosimetric procedures to be fol-lowed with self-contained dry-storage gamma-ray irradiators. If followed, these procedures will help to ensure that calibra-tion and testing will be carried out with acceptable precision and accuracy and that the samples processed with ionizing radiation from gamma rays in a self-contained dry-storage irradiator receive absorbed doses within a predetermined range. 2 This practice covers dosimetry in the use of dry-storage gamma-ray irradiators, namely self-contained dry-storage Cs or Co irradiators (shielded freestanding irra-diators). It does not cover underwater pool sources, panoramic gamma-ray sources such as those raised mechanically or pneumatically to irradiate isotropically into a room or through a collimator, nor does it cover self-contained bremsstrahlung x-ray units. 3 The absorbed dose range for the use of the dry-storage self-contained gamma-ray irradiators covered by this practice is typically 1 to 10 Gy, depending on the application. The absorbed-dose rate range typically is from 10 to 10 Gy/min. 4 This practice describes general procedures applicable to all self-contained dry-storage gamma-ray irradiators. For pro-cedures specific to dosimetry in blood irradiation, see ISO/ ASTM Practice 51939. For procedures specific to dosimetry in radiation research on food and agricultural products, see ISO/ASTM Practice 51900. For procedures specific to radia-tion hardness testing, see ASTM Practice E 1249. For proce-dures specific to the dosimetry in the irradiation of insects for sterile release programs, see ISO/ASTM Guide 51940. In those cases covered by ISO/ASTM Practices 51939, 51900, 51940, or ASTM E 1249, those standards take precedence. In addition, this practice does not cover absorbed-dose rate calibrations of radiation protection instrumentation. 5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.

谁引用了ISO/ASTM 52116-2002 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号