This standard is applicable to three-phase alternating current switches and switch-discon-nectors designed for indoor and outdoor installation for rated voltages above 1 kV and less than 52 kV and power frequencies up to and including 60 Hz. It is also applicable to the operating devices of these switches and to their auxiliary equipment. Switches used in isolated neutral systems or in systems earthed by a high impedance may be required to operate under earth fault conditions. A standard is under consideration, but for the time being, a special agreement between manufacturer and user may be necessary. Notes 1. — Except where special clarification is required the term "switch" is used to refer to all kinds of switches and switch-disconnectors within the scope of this standard. 2. — Earthing switches forming an integral part of a switch are covered by IEC Publication 129: Alternating Current Disconnectors (Isolators) and Earthing Switches. If the earthing switch has a rated short-circuit making current the making tests shall be made according to the requirements in this standard. It is assumed that opening and closing operations are performed according to the manufac-turer's instructions. A making operation may immediately follow a breaking operation but it is strongly recommended that a breaking operation shall not immediately follow a making operation since the current to be broken may then exceed the rated breaking current of the switch.

SIS SS-IEC 265-1-1990由SE-SIS 发布于 1990-9-12。

SIS SS-IEC 265-1-1990的历代版本如下:

  • 1990年09月12日 SIS SS-IEC 265-1-1990 高压开关设备和控制设备.额定电压高于1千伏低于52千伏的高压开关

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 SIS SS-IEC 265-1-1990 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
SIS SS-IEC 265-1-1990
发布日期
1990年09月12日
实施日期
废止日期
发布单位
SE-SIS
适用范围
This standard is applicable to three-phase alternating current switches and switch-discon-nectors designed for indoor and outdoor installation for rated voltages above 1 kV and less than 52 kV and power frequencies up to and including 60 Hz. It is also applicable to the operating devices of these switches and to their auxiliary equipment. Switches used in isolated neutral systems or in systems earthed by a high impedance may be required to operate under earth fault conditions. A standard is under consideration, but for the time being, a special agreement between manufacturer and user may be necessary. Notes 1. — Except where special clarification is required the term "switch" is used to refer to all kinds of switches and switch-disconnectors within the scope of this standard. 2. — Earthing switches forming an integral part of a switch are covered by IEC Publication 129: Alternating Current Disconnectors (Isolators) and Earthing Switches. If the earthing switch has a rated short-circuit making current the making tests shall be made according to the requirements in this standard. It is assumed that opening and closing operations are performed according to the manufac-turer's instructions. A making operation may immediately follow a breaking operation but it is strongly recommended that a breaking operation shall not immediately follow a making operation since the current to be broken may then exceed the rated breaking current of the switch.

SIS SS-IEC 265-1-1990 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号