ASTM D7042-2004
使用Stabinger粘度计测定液体的动态粘度和密度的标准试验方法(和运动粘度的计算)

Standard Test Method for Dynamic Viscosity and Density of Liquids by Stabinger Viscometer (and the Calculation of Kinematic Viscosity)


ASTM D7042-2004 中,可能用到以下耗材

 

Fisher Scientific™ Precision 液体比重计

Fisher Scientific™ Precision 液体比重计

赛默飞实验室耗材产品

 

ACQUITY UPLC HSS T3 C18  1.7 µm,2.1 x 100 mm

ACQUITY UPLC HSS T3 C18 1.7 µm,2.1 x 100 mm

沃特世科技(上海)有限公司(Waters)

 

Fisher Scientific™ Precision 液体比重计

Fisher Scientific™ Precision 液体比重计

赛默飞实验室耗材产品

 

DRYING TUBE, 100 mm

DRYING TUBE, 100 mm

上海安谱科学仪器有限公司

 

COOLING BLOCK 1 KG

COOLING BLOCK 1 KG

上海安谱科学仪器有限公司

 

SYRINGE 10ML

SYRINGE 10ML

上海安谱科学仪器有限公司

 

CONTAINER WITH COOLING LIQUID

CONTAINER WITH COOLING LIQUID

上海安谱科学仪器有限公司

 

U-5000AT+UltrasonicNebulizerSystem,230V,50/60Hz

U-5000AT+UltrasonicNebulizerSystem,230V,50/60Hz

上海安帕特实验室仪器有限公司

 

SP-1200 and Bentone® 34 on 100/120 Supelcoport

SP-1200 and Bentone® 34 on 100/120 Supelcoport

上海安谱科学仪器有限公司

 

Pesticide Method GC Installation 套装 S/SL

Pesticide Method GC Installation 套装 S/SL

上海安谱科学仪器有限公司

 

MINISART-PLUS 0.45UM SYRINGE FILTER W/IN TEGRAL PREFILTER

MINISART-PLUS 0.45UM SYRINGE FILTER W/IN TEGRAL PREFILTER

上海安谱科学仪器有限公司

 

Sample,Sus,Fe,BasC

Sample,Sus,Fe,BasC

北京博德恒悦科贸有限公司

 

Cover,Sample,Biomate3

Cover,Sample,Biomate3

北京博德恒悦科贸有限公司

 

Loop,Sample,500uL,SS

Loop,Sample,500uL,SS

北京博德恒悦科贸有限公司

 

Sample,Sus,Fe/Mn

Sample,Sus,Fe/Mn

北京博德恒悦科贸有限公司

 

Pour out connection

Pour out connection

上海安谱科学仪器有限公司

 

Sample,Cal.235,KBr,Omega

Sample,Cal.235,KBr,Omega

北京博德恒悦科贸有限公司

 

ASTM137C

ASTM137C

沃尔德姆(香港)有限公司

 

ASTM134C

ASTM134C

沃尔德姆(香港)有限公司

 

TITAN-MSF CELL. 0.2

TITAN-MSF CELL. 0.2

上海安谱科学仪器有限公司

 

ASTM127C

ASTM127C

沃尔德姆(香港)有限公司

 

Heraeus氘灯(适用PELC200/785AN2920149)

Heraeus氘灯(适用PELC200/785AN2920149)

上海楚柏实验室设备有限公司

 

ASTM136C

ASTM136C

沃尔德姆(香港)有限公司

 

ASTM129C

ASTM129C

沃尔德姆(香港)有限公司

 

MINI-BUCK AIR FLOW CALIBRATOR M-5

MINI-BUCK AIR FLOW CALIBRATOR M-5

上海安谱科学仪器有限公司

 

MINI-BUCK AIR FLOW CALIBRATOR M-30

MINI-BUCK AIR FLOW CALIBRATOR M-30

上海安谱科学仪器有限公司

 

2-POSITION BASEPLATE FOR HIGH FLOW LC-MS

2-POSITION BASEPLATE FOR HIGH FLOW LC-MS

上海安谱科学仪器有限公司

 

HIS-SELECT 6.4ML HIGH FLOW REZORIAN CART

HIS-SELECT 6.4ML HIGH FLOW REZORIAN CART

上海安谱科学仪器有限公司

 

DRYING TUBE ACC. TO  DR. WüNSCH, CONE ST 29/32

DRYING TUBE ACC. TO DR. WüNSCH, CONE ST 29/32

上海安谱科学仪器有限公司

 

BASE, WSS, TRIPLE  PROFILE, 100 CM

BASE, WSS, TRIPLE PROFILE, 100 CM

上海安谱科学仪器有限公司

 

GPC HFIP-G 8B HFIP solvent

GPC HFIP-G 8B HFIP solvent

上海安谱科学仪器有限公司

 

BodtrakTubing,Internal

BodtrakTubing,Internal

北京博德恒悦科贸有限公司

 

GPC HFIP-G 8B HFIP solvent

GPC HFIP-G 8B HFIP solvent

上海安谱科学仪器有限公司

 

RSpak DC-G 4A  Polymer based

RSpak DC-G 4A Polymer based

上海安谱科学仪器有限公司

 

Lid, PE-LD, for bucket 5 l

Lid, PE-LD, for bucket 5 l

上海安谱科学仪器有限公司

 

TENAX TA SS TDU TUBE 115MM

TENAX TA SS TDU TUBE 115MM

上海安谱科学仪器有限公司

 

ASTM D7042-2004



标准号
ASTM D7042-2004
发布日期
2004年
实施日期
废止日期
中国标准分类号
N51
国际标准分类号
17.060 (Measurement of volume, mass, density, visc
发布单位
US-ASTM
适用范围

Many petroleum products, and some non-petroleum materials, are used as lubricants and the correct operation of the equipment depends upon the appropriate viscosity of the liquid being used. In addition, the viscosity of many petroleum fuels is important for the estimation of optimum storage, handling, and operational conditions. Thus, the accurate determination of viscosity is essential to many product specifications.

Density is a fundamental physical property that can be used in conjunction with other properties to characterize both the light and heavy fractions of petroleum and petroleum products.

Determination of the density or relative density of petroleum and its products is necessary for the conversion of measured volumes to volumes at the standard temperature of 15x00B0;C.

1.1 This test method specifies a procedure for the concurrent measurement of both the dynamic viscosity, 951;, and the density, 961;, of liquid petroleum products and crude oils, both transparent and opaque. The kinematic viscosity, ny, can be obtained by dividing the dynamic viscosity, 951;, by the density, 961;, obtained at the same test temperature.

1.2 The result obtained from this test method is dependent upon the behavior of the sample and is intended for application to liquids for which primarily the shear stress and shear rate are proportional (Newtonian flow behavior).

1.3 While the precision has only been determined for base oils in the viscosity range from 2.05 to 456 mPas at 40176;C and from 0.83 to 31.6 mPas at 100176;C and in the density range from 0.82 to 0.92 g/mL at 15176;C (see 15.4), the test method can be applied to a wider range of materials, viscosity, density, and temperature. For materials not listed in Precision and Bias (Section 15), the precision and bias may not be applicable.

1.4 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. The accepted units of measure for density are grams per millilitre (g/mL) or kilograms per cubic metre (kg/m3).

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.