CENELEC EN 60738-1-4-2008

Thermistors - Directly heated positive step-function temperature coefficient - Part 1-4: Blank detail specification - Sensing application - Assessment level EZ (IEC 60738-1-4:2008)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CENELEC EN 60738-1-4-2008 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
CENELEC EN 60738-1-4-2008
发布日期
2008年04月
实施日期
废止日期
国际标准分类号
31.040.30
发布单位
IX-CEN
适用范围
1.1 Method(s) of mounting (to be inserted) (See IEC 60738-1:2006, 7.30). 1.2 Dimensions (All dimensions are in millimetres or inches and millimetres; it shall be stated which dimensions are suitable for gauging). Dimensioned drawing(s) shall be given in the detail specification. If necessary, the dimensions may be listed in tabular form with reference to styles or codes. 1.3 Coating The detail specification shall state: a) whether the thermistor is insulated or non-insulated; b) the material; c) the colour, if applicable. 1.4 Terminations The detail specification shall state whether the terminations are suitable for soldering. If they are not, suitable methods of connection shall be stated for example: welding, clamping or crimping. 1.5 Flammability The detail specification shall state whether the thermistor is actively or passively flammable if applicable. The test method shall be given in the test schedule. 1.6 Resistance to solvents The detail specification shall state whether the coating and the marking of the thermistor are solvent resistant if applicable. The test methods shall be given in the test schedule. 1.7 Packaging The detail specification shall give the following information (if required): a) whether bulk packed or taped and if taped, drawing or references; b) the dimensions of the immediate packaging and the number of thermistors packed;c) the dimensions of the outer package and the number of immediate packages; d) methods of disposal of the packaging material. 1.8 Electrical data/Ratings and characteristics The detail specification shall give units and tolerances or limiting values for the following parameters. If necessary, electrical data may be listed in tabular form, with reference to styles and codes. Upper/Lower category temperatures (UCT/LCT); Operating temperature range at maximum voltage; Maximum voltage (Umax.); Zero-power resistance (RT); Resistance RNF at TNF (if applicable, see IEC 60738-1:2006, Figure 2); Isolation voltage (insulated thermistors only); Insulation resistance (insulated thermistors only); Response time.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号