SAE J2470-2009
评定液压阀对锁定污染物敏感性的方法

Hydraulic Fluid Power Valves Method for Assessing the Lock Sensitivity to Contaminants


SAE J2470-2009 发布历史

This SAE Recommended Practice defines a procedure, which will aid in assessing the contaminant sensitivity of hydraulic valves. The approach taken defines a test procedure with flexibility for testing valves in a wide range of contamination levels. The user of this procedure must establish the contamination levels for testing. Three levels are suggested which should cover the range for most valve applications. This procedure does not establish the contaminant sensitivity requirements for any valve. The user of this procedure needs to be aware of the system contamination level that the valve will operate in and select test contamination levels significantly higher than the operating level to assess the suitability of the valve. The test procedure permits a valve to be tested without disassembly and therefore permits protection of proprietary design information. This procedure assesses the contamination sensitivity of valves by contaminant lock. The procedure indicates the sensitivity of valves by contaminant lock due to various sizes of contaminants. The test is designed to assess the contaminant sensitivity of valves in tests of relatively short duration. See Appendix A for guidance as to how the tests and their results may be used. The tests are purposely designed to be severe in order to be applicable to a wide range of contaminated environments. The use of valves in many applications and for various purposes results in differing levels of acceptable performance. That is, the same valve may be unacceptable - in relation to operation in a contaminated environment - in one application and be acceptable in another. The user must make that decision based on a review of the expected level of the specific application and the test results obtained.

SAE J2470-2009由美国机动车工程师协会 US-SAE 发布于 2009-01-22。

SAE J2470-2009 在中国标准分类中归属于: T11 发动机与附属装置,在国际标准分类中归属于: 23.100.50 控制部件,43.040.50 传动装置、悬挂装置。

SAE J2470-2009 发布之时,引用了标准

  • ISO 1219-1-2006 液压传动系统和元件.图形符号和电路图.第1部分:传统使用和数据处理应用的图形符号
  • ISO 4021-1992 液压传动 颗粒污染分析 从工作系统管路中提取油样
  • ISO 4405-1991 液压传动 油液污染度 采用重量法测定颗粒污染度
  • ISO 4406-1999 液压传动 油液 固体颗粒污染等级代号法
  • ISO 5598-2008 流体传动系统和元件.词汇
  • ISO 6403-1988 液压传动 控制流量及压力的阀 试验方法
  • ISO 10770-1-1998 液压传动 电调制液压控制阀 第1部分:四通流量控制阀的试验方法
  • ISO 10770-2-1998 液压传动 电调制液压控制阀 第2部分:三通流量控制阀的试验方法
  • ISO 11500-2008 液压传动.用遮光法自动颗粒计算对液体样品的颗粒污染物等级的测定
  • ISO 12103-1-1997 道路车辆 用于滤清器评价的粉尘试验 第1部分:亚利桑那州试验粉尘
  • ISO 16889-2008 液压传动过滤器.滤波器元件过滤性能的评估用多次通过法
  • SAE ARP 490F-2008 电液伺服阀

SAE J2470-2009的历代版本如下:

  • 1999年10月01日 SAE J2470-1999 SAE J 2470-1999
  • 2006年11月01日 SAE J2470-2006 评估阀门对油液污染等级用液压传动阀门法
  • 2009年01月22日 SAE J2470-2009 评定液压阀对锁定污染物敏感性的方法

SAE J2470-2009



标准号
SAE J2470-2009
发布日期
2009年01月22日
实施日期
废止日期
中国标准分类号
T11
国际标准分类号
23.100.50;43.040.50
发布单位
美国机动车工程师协会
引用标准
ISO 1219-1-2006 ISO 4021-1992 ISO 4405-1991 ISO 4406-1999 ISO 5598-2008 ISO 6403-1988 ISO 10770-1-1998 ISO 10770-2-1998 ISO 11500-2008 ISO 12103-1-1997 ISO 16889-2008 SAE ARP 490F-2008 SAE ARP 785A-1996
被代替标准
SAE J 2470-2006
适用范围
This SAE Recommended Practice defines a procedure, which will aid in assessing the contaminant sensitivity of hydraulic valves. The approach taken defines a test procedure with flexibility for testing valves in a wide range of contamination levels. The user of this procedure must establish the contamination levels for testing. Three levels are suggested which should cover the range for most valve applications. This procedure does not establish the contaminant sensitivity requirements for any valve. The user of this procedure needs to be aware of the system contamination level that the valve will operate in and select test contamination levels significantly higher than the operating level to assess the suitability of the valve. The test procedure permits a valve to be tested without disassembly and therefore permits protection of proprietary design information. This procedure assesses the contamination sensitivity of valves by contaminant lock. The procedure indicates the sensitivity of valves by contaminant lock due to various sizes of contaminants. The test is designed to assess the contaminant sensitivity of valves in tests of relatively short duration. See Appendix A for guidance as to how the tests and their results may be used. The tests are purposely designed to be severe in order to be applicable to a wide range of contaminated environments. The use of valves in many applications and for various purposes results in differing levels of acceptable performance. That is, the same valve may be unacceptable - in relation to operation in a contaminated environment - in one application and be acceptable in another. The user must make that decision based on a review of the expected level of the specific application and the test results obtained.