Sometimes coal tar and petroleum pitches are heat treated thereby forming mesophase spheroids. The mesophase may be partially soluble in quinoline and cannot be estimated by the quinoline insoluble test (Test Method D 2318
The mesophase initially forms as spheroids that may coalesce to form a variety of asymmetrical shapes. The smallest mesophase particle that can be detected with certainty at 400x00D7; or 500x00D7; magnification is 4 x03BC;m in diameter; mesophase particles sizes less than 4 x03BC;m should be ignored. If mesophase material less than 4 x03BC;m in size is of interest, then magnifications of 1000 to 1800x00D7; shall be used and the results should be appropriately identified. This method is limited to determining minor levels of mesophase, that is, x2264;20 % mesophase.
1.1 This test method covers laboratory procedures for the preparation of granular and melted samples for microscopic analysis using reflected light to identify and estimate the amount and size of the mesophase.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved