BS EN 50508:2009
高压装置上电气操作用多用途绝缘棒

Multi-purpose insulating sticks for electrical operations on high voltage installations


标准号
BS EN 50508:2009
发布
2009年
发布单位
英国标准学会
当前最新
BS EN 50508:2009
 
 
引用标准
EN 60068-1:1994 EN 60068-2-32:1993 EN 60068-2-75:1997 EN 60855:1996 EN 61235:1995 EN 61477 HD 588.1 S1-1991 IEC 60050 IEC 60417 ISO 48
被代替标准
06/30159668 DC-2006
适用范围
This European Standard specifies the requirements and tests to be fulfilled by the multipurpose insulating sticks intended to perform a range of operations in high voltage installations by means of the attached appropriate tools, for example: • connection and disconnection of disconnectors or other equipment operated by the stick, • fuse replacement with an attached tool, operations like: • voltage absence verification, using a detector as a separate device in accordance with EN 61243-1; • earthing and short circuiting installations, using devices in accordance with EN 61230; • placing insulating screens in order to provide protection against adjacent live parts; • testing and measurement; • any other operation or verification on the electrical installation, provided that the mechanical requirements do not exceed those assured by the stick design and the worker shall remain at a safety distance; • rescue of accident victims. This European Standard is applicable to the insulating sticks made of a single continuous tube or rod or multiple tube or rod sections connected to each other, to be used both indoors or outdoors on electrical systems for voltages of 1 kV to 765 kV a.c., frequencies of 50 Hz and/or 60 Hz and in the normal range of temperatures of -25 ºC to +55 ºC and at a relative humidity between 20 % and 93 %. For the purpose of this standard, “tube” is used for “tube” and “rod”. Annex B includes considerations about the use under wet conditions. NOTE It is a general practice to use an insulating stick on d.c. installations with the same value of nominal voltage. That use shall comply with the national regulations. This European Standard is not applicable to • sticks covered by EN 60832, • telescopic sticks covered by EN 62193, • sticks with mobile internal or external operating rods, as those used directly for fuse replacement, • single purpose sticks, especially designed to cover a single operation, generally as a complete equipment such as voltage detectors covered by EN 61243-1. NOTE Except where otherwise specified, all the voltages defined in this European Standard refer to values of phase-to-phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages should be used to determine the operating voltage.

BS EN 50508:2009相似标准


推荐

使用高压验电器时须注意哪些事项?

(2)使用前,要按所测设备(线路)的电压等级将绝缘拉伸至规定长度,选用合适型号的指示器和绝缘,并对指示器进行检查,投人使用的高压验电器必须是经电气试验合格的。(3)对回转式高压验电器,使用前应把检验过的指示器旋接在绝缘固定,并用绸布将其表面擦拭干净,然后转动至所需角度,以便使用时观察方便。...

KYN28A-12/24金属铠装抽出式开关柜

闭锁装置采用的电磁锁应符合JB/DQ2181-87《高压开关设备用电磁锁技术条件》的要求。   5. 闭锁装置应符合开关柜程序操作的要求,装置的锁定位置应与开关柜被闭锁的动机构的实际位置一致;当未完全规定的程序操作,不能继续进行操作;进行非程序操作时,操作应自动地无法进行。   6. 采用电气闭锁方案时,闭锁元件的电源应与继电保护回路分开。闭锁回路和接点应满足闭锁要求。...

直流高压发生器安全操作要求

2、对高压试验设备及试品在高压试验前、试验后的放电,必须先将接地操作的接地线可靠地连接在接地点,再用接地操作放电。对大电容的直流试验设备和试品的放电,应先用带放电电阻的接地操作放电,然后再直接短路接地放电。变更冲击电压发生器波头和波尾电阻或直流发生器更换极性前,必须对电容器逐级短路接地放电或启动短路接地装置。3、对高压试验设备和试品在进行高压试验前、后的放电时间,一般不短于5 min。...

无线高压核相仪的工作保养及现场注意事项

4、使用时应认真执行本单位安全规章制度,并严格遵守DL408-91安全工作规程(发电厂变电所电气部份)相关规定,仔细保管仪器,定期检查绝缘。5、绝缘杆为6节伸缩式,在使用时,不管工作电压是否为电压,均要把伸缩绝缘杆拉到长状态(约3.1米),握手时只能握在第六节,不得在第五节握手。6、使用过程中避免同时使用无线电发射装置(对讲机等),以免干扰接收器。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号