ANSI/AWWA C518-2008
给水厂设备用双垫圈回转止回阀

Dual-Disc Swing-Check Valves for Waterworks Service


ANSI/AWWA C518-2008 中,可能用到以下仪器设备

 

DNA800超微量核酸蛋白测定仪

DNA800超微量核酸蛋白测定仪

天美仪拓实验室设备(上海)有限公司

 

暗箱式三用紫外分析仪

暗箱式三用紫外分析仪

保定兰格恒流泵有限公司

 

紫外交联仪

紫外交联仪

北京中科科尔仪器有限公司

 

杂交/紫外交联仪

杂交/紫外交联仪

北京中科科尔仪器有限公司

 

LabChip DS微流控紫外可见全光谱分析仪

LabChip DS微流控紫外可见全光谱分析仪

珀金埃尔默企业管理(上海)有限公司PerkinElmer

 

Colibri LB 915超微量分光光度计

Colibri LB 915超微量分光光度计

科瑞恩特(北京)科技有限公司

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ANSI/AWWA C518-2008 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ANSI/AWWA C518-2008
发布日期
2008年01月27日
实施日期
2008年10月01日
废止日期
中国标准分类号
J16
发布单位
US-AWWA
引用标准
ASME B16.1 ANSI/AWWA C550 ANSI/AWWA C606 ASTM A48 ASTM A126 ASTM A240 ASTM A276 ASTM A313 ASTM A395 ASTM A536 ASTM A743 ASTM B62 ASTM B584 ASTM B763 ASTM D395 ASTM D429 ASTM D471 ASTM D1149 MSS SP-6
适用范围
This standard establishes minimum requirements for dual-disc swing-check valves, 2-in. (50-mm) through 48-in. (1,200-mm) NPS for clean water having a pH range from 6 to 10 and a temperature range of 33~-125~F (0.6~-52~C). 1.1.1 Body types. Valves described in this standard are provided with wafer or threaded-lug ends for installation between ANSI Class 125 flanges or grooved ends for use with IPS pressure pipe. 1.1.2 Gray-iron pressure ratings. "l-he minimum design working water pressure for gray-iron valves shall be 200 psig (1,380 kPa) for 2-in. through 12-in. (50-mm through 300-mm) sizes and 150 psig (1,030 kPa) for 14-in. through 48-in. (350-mm through 1,200-mm) sizes. 1.1.3 Ductile-iron pressure ratings. The minimum design working water pressure for ductile-iron valves shall be 250 psig (1,380 kPa) for 2-in. through 48-in. (50-mm through 1,200-mm) sizes. 1.1.4 Fluid velocity rating. The maximum fluid velocity shall be 16 ft/sec (4.9 m/sec). 1.1.5 Installations. Dual-disc swing-check valves are designed for installation in horizontal pipelines and in vertical lines with flow in the upward direction. Valves must be installed with hinge pins in the vertical position for horizontal pipeline installations. ~he valves are not approved for installations in vertical lines with flow down where valve closure may not occur. 1.1.6 Excepted conditions. Conditions of water hammer, hydraulic pulsa- tion, and excessive noise are beyond the scope of this standard and require special design and construction consideration.