DS/ISO 5725-4:1995
测量方法和测量结果的精确度(真实性和准确性).第4部分:测定标准测量方法真实性的基本方法

Accuracy (trueness and precision) of measurement methods and results - Part 4: Basic methods for the determination of the trueness of a standard measurement method


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 DS/ISO 5725-4:1995 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
DS/ISO 5725-4:1995
发布
1995年
发布单位
丹麦标准化协会
当前最新
DS/ISO 5725-4:1995
 
 
适用范围
1 This part of ISO 5725 provides basic methods for estimating the bias of a measurement method and the laboratory bias when a measurement method is applied. 2 It is concemed exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the test result, although the single value may be the outcome of a calculation from a set of observations. 3 In order that the measurements are made in the same way, it is important that the measurement method has been standardized. All measurements are to be carried out according to that standard method. 4 Bias values give quantitative estimates of the ability of a measurement method to give the correct (true) result. When a value for the bias of a measure ment method is quoted, together with a test result obtained by that method, there is an implication that the same characteristic is being measured in exactly the same way. 5 This part of ISO 5725 can be applied only if the accepted reference value can be established as a conventional true value, for example by measurement standards or suitable reference matehals or by refer- ring to a reference measurement method or by preparation of a known sample. Reference materials could be either a) certified reference materials; b) materials manufactured for the purpose of the experiment with known properties; or c) materials whose properties have been established by measurements using an alternative measurement method whose bias is known to be negligible. 1.6 This part of ISO 5725 considers only those cases where it is sufficient to estimate bias on one level at a time. It is not applicable if the bias in the measurement of one property is affected by the level of a second property (i.e. it does not consider inter-ferences). Comparison of the trueness of two measurement methods is considered in ISO 5725-6. NOTE 1 In this part of ISO 5725, bias is considered only at one level at a time. Therefore the index;' for the level has been omitted throughout.

DS/ISO 5725-4:1995相似标准


推荐





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号