引用标准
ANSI C84.1 ASME Boiler and Pressure Vessel Code (BPV) ASTM D1933 ASTM D2225 ASTM D3487 ASTM D5222 ASTM D92 CGA V-1 IEEE Std 315 IEEE Std 315A IEEE Std 469 IEEE Std C57.12.70 IEEE Std C57.12.80 IEEE Std C57.12.90 IEEE Std C57.131 IEEE Std C57.19.01
适用范围
IMPORTANT NOTICE: This standard is not intended to ensure safety, security, health, or environmental protection. Implementers of the standard are responsible for determining appropriate safety, security, environmental, and health practices or regulatory requirements. This IEEE document is made available for use subject to important notices and legal disclaimers. These notices and disclaimers appear in all publications containing this document and may be found under the heading “Important Notice” or “Important Notices and Disclaimers Concerning IEEE Documents.” They can also be obtained on request from IEEE or viewed at http://standards.ieee.org/IPR/disclaimers.html. This standard describes electrical and mechanical requirements of liquid-immersed distribution and power transformers, and autotransformers and regulating transformers, single-phase and polyphase, with voltages of 601 V or higher in the highest voltage winding. This standard applies to all liquid-immersed distribution, power, and regulating transformers that do not belong to the following types of apparatus: a) Instrument transformers b) Step voltage and induction voltage regulators c) Arc furnace transformers d) Rectifier transformers e) Specialty transformers f) Grounding transformers g) Mobile transformers h) Mine transformers

IEEE Std C57.12.00-2010相似标准


推荐

变压器用途及分类

3>按冷却介质分类:有干式变压器、液()变压器及充气变压器等。4>按冷却方式分类:有自然冷、风冷、水冷、强迫循环风(水)冷方式、及水内冷等。5>按线圈数量分类:有自耦变压器、双绕组及三绕组变压器等。6>按导电材质分类:有铜线变压器、铝线变压器及半铜半铝、超导等变压器。7>按调压方式分类:可分为无励磁调压变压器、有载调压变压器。...

这些变压器,你分得清吗?

1、对高电压绝缘试验基本要求和规定  变压器绕组是按高运行电压Um以及相应绝缘水平进行检验,下表是标准GB1094.3—2003《电力变压器 第三部分:绝缘水平、绝缘试验外绝缘空气间隙》规定绝缘试验项目。  2、例行(出厂)试验项目  (1)绕组直流电阻测量:在所有分接引出端上进行测量。  (2)变比测量:在所有分接位置上进行测量。  (3)接线组别检测:在额定分接位置上进行测试。  ...

工频耐压试验(仪)装置详细说明

  YD型工频耐压试验装置适用于电力系统对各种高压电气设备、绝缘材料进行工频或直流高压下绝缘强度试验,一般是由YDJ系列试验变压器XC系列操作箱两部分组成。   ...

充气变压器用途

变压器按铁心结构分有心变压器变压器;按相数分有单相、三相及多相变压器;按冷却方式分有干充气变压器;按容量大小分有小型、中型、大型特大型变压器;按用途分有电力变压器专用变压器充气变压器一般是指用于各种高压电力、电气设备检测预防性试验升压试验设备。...