IEC 60532:2010
辐射防护仪表.固定式能量在50 keV和7 MeV之间X和γ辐射的剂量率仪、报警装置和监测仪

Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV


标准号
IEC 60532:2010
发布
2010年
中文版
GB/T 14054-2013 (等同采用的中文版本)
发布单位
国际电工委员会
当前最新
IEC 60532:2010
 
 
适用范围
This International Standard applies to installed dose rate meters, warning assemblies and monitors that are used to prevent or mitigate a minor radioactive release, or minor degradation of fuel, within the nuclear power plants /nuclear facility design basis, and to warn personnel or to ensure their safety during or following events that involve or result in release of radioactivity in the nuclear power plants (NPP) /nuclear facility (NF), or risk of radiation exposure. This equipment is typically classified as category “A” or “B” or “C” or “not classified” in IEC 61226. It covers equipment intended to isotropically measure air kerma, ambient dose equivalent or other exposure quantities due to X or gamma radiation of energy between 50 keV and 7 MeV. The equipment is intended primarily for the purpose of radiological protection, and may play an auxiliary or indirect role in the achievement or maintenance of nuclear plant safety. Instruments measuring over a more limited energy range fall within the scope of this standard provided they cover at least the range of 80 keV to 1,5 MeV. Assemblies of this type are commonly defined as area radiation monitors. They are normally employed to determine continuously the radiological situation in working areas in which the radiation field may change with time, for example nuclear power plants, particle accelerators, high active laboratories, fuel reprocessing plants, and to provide alarms when the radiation field goes outside predetermined limits. They are also employed to act in safety related protection systems, such as personnel access control systems which allow access to areas which can be subject to radiation fields. This standard also gives guidance applicable to equipment for use in pulsed radiation fields, for example, those emanating from pulsed radiation or particle accelerators. This guidance is important, since the operation of the majority of the equipment defined by this standard in pulsed fields will give false readings. The assemblies considered in this standard comprise at least: ? a detector assembly (e.g, ionization chamber, Geiger-Muller tube, scintillation counters, semiconductors); ? a measuring assembly, which may be fitted into a centralized panel which, in the case of warning assemblies and monitors, provides signal outputs and contacts capable of activating alarm or trip/interlock circuits for the purpose of radiation protection. This standard is also applicable to installed dose rate measuring assemblies designed for special applications (e.g. very high dose rates). However, some of the requirements may need to be amended or supplemented according to the particular characteristics of such assemblies. This standard is not applicable to criticality monitors. Assemblies designed to perform combined functions should comply with the requirements pertaining to each of these functions. This standard specifies general characteristics, general test procedures, radiation, electrical, safety, and environmental characteristics and the identification certificate for the assemblies defined above.

IEC 60532:2010相似标准


推荐

RAM-Ⅰ xγ辐射报警

   RAM-Ⅰ xγ辐射报警   RAM-I型是一种新型固定式安装xγ辐射连续监测报警装置,它采用特殊设计前置放大电路与硅探测器,具有灵敏度高、操作方便、自动显示、数据存储超阈报警等特点,能实时给出xγ辐射剂量率(μGy/h与μSv/h可以转换显示),同时可给出个人累计剂量(μSv),也可作为在线辐射监测系统实现实时监控与超阈安全报警。   ...

辐射检测列举

智能化射线辐射   REN500A 型智能化х、γ辐射采用高灵敏闪烁晶体作为探测器 , 反应速度快 , 国内同类仪器相比,该辐射检测具有更宽剂量率测量范围。该辐射检测除能测高能、低能γ射线外,还能对低能 X 射线进行准确测量,具有良好能量响应特性。此外通过配套 RenRiRate 剂量率管理软件可将存储数据读出后分析。...

辐射急性初期症状有哪些

6.温度:操作 -10℃~+50℃;贮存 -20℃~+60℃;7能量响应:25KeV~3MeV,变化限值为15%;8、γ剂量率指示固有误差:不大于10%;角响应:(137Cs)不超过15%。...

医院射线诊断机与治疗机机房辐射防护工程建设

RAM-II型 辐射剂量率 6.医护人员个人剂量监测     采用FJ2000或SDM2000个人剂量报警用于工作人员佩带,每次工作完成,必须记录辐射剂量值,以便建立个人档案,确保个人安全,也是职业卫生安全要求。    7.医护人员与病人个体防护     工作人员与病人(局部)个体辐射防护除穿戴普通工作服、手套、鞋、帽外,射线机意外事故或设备检修情况下,务必穿戴辐射防护铅衣。 ...


IEC 60532:2010 中可能用到的仪器设备


谁引用了IEC 60532:2010 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved