BS ISO 16362-2005
环境空气.高效液体色谱法测定粒子相位多环芳烃

Ambient air - Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography


BS ISO 16362-2005 发布历史

This International Standard specifies sampling, clean-up and analysis procedures for the quantitative determination of low volatility (particle-bound) polycyclic aromatic hydrocarbons (PAHs) in ambient air. For sampling, a low-volume or a medium/high-volume sampling device may be used. Sampling times between 1 h and 24 h are possible. The sampling volume flowrates can range from 1 m/h to 4 m/h ("low volume sampler") or from 10 m/h to about 90 m/h ("medium/high-volume sampler"). In any case, the linear face velocity at the collection filter should range between about 0,5 m/s and 0,9 m/s. The method has been validated for sampling periods up to 24 h. The detection limits for single PAHs and the standard deviations resulting from duplicate measurements are listed in 9.2 and Annex D respectively. This International Standard describes a sampling and analysis procedure for PAH that involves collection from air onto a filter followed by analysis using high performance liquid chromatography usually with fluorescence detector (FLD). The use of a diode array detector (DAD) is possible. The combination of both detector types is also possible (see Annex B). Total suspended particulate matter is sampled. Generally, compounds having a boiling point above 430 ℃ (vapour pressure less than 10 kPa at 25 ℃, e.g. chrysene, benz[a]anthracene) can be collected efficiently on the filter at low ambient temperatures (e.g. below 10 ℃). In contrast, at higher temperatures (above 30 ℃, see also ISO 12884), only PAHs having boiling points above 475 ℃ (vapour pressure less than 10kPa at 25 ℃) are determined quantitatively (see Annex F).

BS ISO 16362-2005由英国标准学会 GB-BSI 发布于 2005-03-10,并于 2005-03-10 实施。

BS ISO 16362-2005 在中国标准分类中归属于: Z15 大气环境有毒害物质分析方法。

BS ISO 16362-2005的历代版本如下:

  • 2005年03月10日 BS ISO 16362-2005 环境空气.高效液体色谱法测定粒子相位多环芳烃

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS ISO 16362-2005 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
BS ISO 16362-2005
发布日期
2005年03月10日
实施日期
2005年03月10日
废止日期
中国标准分类号
Z15
发布单位
GB-BSI
被代替标准
02/564017 DC-2002
适用范围
This International Standard specifies sampling, clean-up and analysis procedures for the quantitative determination of low volatility (particle-bound) polycyclic aromatic hydrocarbons (PAHs) in ambient air. For sampling, a low-volume or a medium/high-volume sampling device may be used. Sampling times between 1 h and 24 h are possible. The sampling volume flowrates can range from 1 m/h to 4 m/h ("low volume sampler") or from 10 m/h to about 90 m/h ("medium/high-volume sampler"). In any case, the linear face velocity at the collection filter should range between about 0,5 m/s and 0,9 m/s. The method has been validated for sampling periods up to 24 h. The detection limits for single PAHs and the standard deviations resulting from duplicate measurements are listed in 9.2 and Annex D respectively. This International Standard describes a sampling and analysis procedure for PAH that involves collection from air onto a filter followed by analysis using high performance liquid chromatography usually with fluorescence detector (FLD). The use of a diode array detector (DAD) is possible. The combination of both detector types is also possible (see Annex B). Total suspended particulate matter is sampled. Generally, compounds having a boiling point above 430 ℃ (vapour pressure less than 10 kPa at 25 ℃, e.g. chrysene, benz[a]anthracene) can be collected efficiently on the filter at low ambient temperatures (e.g. below 10 ℃). In contrast, at higher temperatures (above 30 ℃, see also ISO 12884), only PAHs having boiling points above 475 ℃ (vapour pressure less than 10kPa at 25 ℃) are determined quantitatively (see Annex F).




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号