ASTM D7690-2011
用有分析式铁谱仪检验使用中的润滑油的微粒微观特性的标准操作规程

Standard Practice for Microscopic Characterization of Particles from In-Service Lubricants by Analytical Ferrography


ASTM D7690-2011 中,可能用到以下仪器设备

 

斯派超科技 蓟管式分析铁谱仪 T2FM 500

斯派超科技 蓟管式分析铁谱仪 T2FM 500

上海人和科学仪器有限公司

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM D7690-2011 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ASTM D7690-2011
发布日期
2011年
实施日期
废止日期
中国标准分类号
E34
国际标准分类号
75.100
发布单位
美国材料与试验协会
适用范围

The objective of ferrography is to diagnose the operational condition of the machine sampled based on the quantity and type of particles observed in the oil. After break-in, normally running machines exhibit consistent particle concentration and particle types from sample to sample. An increase in particle concentration, accompanied by an increase in size and severity of particle types is indicative of initiation of a fault. This practice describes commonly found particles in in-service lubricants, but does not address methodology for quantification of particle concentration.

This practice is provided to promote improved and expanded use of ferrographic analysis with in-service lubricant analysis. It helps overcome some perceived complexity and resulting intimidation that effectively limits ferrographic analysis to the hands of a specialized and very limited number of practitioners. Standardized terminology and common reporting formats provide consistent interpretation and general understanding.

Without particulate debris analysis, in-service lubricant analysis results often fall short of concluding likely root cause or potential severity from analytical results because of missing information about the possible identification or extent of damaging mechanisms.

Ferrographic analysis, as described in this practice, provides additional particle identification capabilities beyond methods described in Guide for the following reasons:

(1) The ferrographic particle separation method is magnetic thus making it possible to readily distinguish between ferrous and nonferrous wear particles.

(2) Ferrography separates ferrous (magnetic) particles by size.

(3) Deposition is on a glass substrate so that particles may be examined using transmitted light as well as reflected light allowing particle types to be identified that cannot be identified when examination is done using only reflected light.

(4) Ferrograms may be heat treated providing important distinctions between ferrous alloy types (steel versus cast iron), further distinctions among various nonferrous alloys and distinctions between inorganic and organic particles.

Caution must be exercised when drawing conclusions from the particles found in a particular sample, especially if the sample being examined is the first from that type of machine. Some machines, during normal operation, generate wear particles that would be considered highly abnormal in other machines. For example, many gear boxes generate severe wear particles throughout their expected service life, whereas just a few severe wear particles from an aircraft gas turbine oil sample may be highly abnormal. Sound diagnostics require that a baseline, or typical wear particle signature, be established for each machine type under surveillance.

1.1 This practice covers the identification by optical microscopy of wear and contaminant particles commonly found in used lubricant and hydraulic oil samples that have been deposited on ferrograms. This practice relates to the identification of particles, but not to methods of determining particle concentration.

1.2 This practice interfaces with but generally excludes particles generated in the absence of lubrication, such as may be generated by erosion, impaction, gouging, or polishing.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applic......


ASTM D7690-2011 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号