CEN/TS 16115-1-2011
环境空气质量的测量.第1部分:确定模具使用滤波器采样系统和文化分析

Ambient air quality - Measurement of bioaerosols - Part 1: Determination of moulds using filter sampling systems and culture-based analyses


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CEN/TS 16115-1-2011 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
CEN/TS 16115-1-2011
发布日期
2011年04月01日
实施日期
废止日期
国际标准分类号
13.040.20
发布单位
IX-CEN
引用标准
EN ISO 8199-2007
被代替标准
FprCEN/TS 16115-2010
适用范围
This Technical Specification describes the measurement of moulds in ambient air in order to identify, quantify and characterize bioaerosol pollution in ambient air resulting from emissions from different sources. The method described specifies the sampling of moulds as part of the suspended particulate matter (SPM, here particles with aerodynamic diameter up to ca. 30 μm) using a filter sampling system with gelatine/poly-carbonate filter combination followed by the culture-based analyses on DG18 agar. The sampling duration can be varied between 10 min to 24 h. The health effect of bioaerosols is not limited to any particle fraction, therefore,This document describes the sampling of moulds as part of the suspended particulate matter as a convention method. NOTE The sampling method described inThis document in principle is likely to be appropriate for the sampling of actinomycetes and other spore-forming bacteria (resistant to desiccation). For these species a special analytical procedure using different culture media should be applied, butThis is not within the scope of this document. The standard method set out inThis Technical Specification is accepted by convention as reference method. The measured quantity, here the number of colony forming units per cubic meter (CFU/m3), is determined by the inlet design of the sampling head, the associated operational parameters and the analytical procedure. Standardized methods for sampling, detection and enumeration of moulds including standards for sampling strategies are important for comparative assessment of moulds in ambient air. Before doing any measurements a plan for the measurement strategy is necessary (see CEN/TS 16115-2). WARNING-The use of this Technical Specification may involve hazardous materials, operations and equipment.This Technical Specification does not purport to address all the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

谁引用了CEN/TS 16115-1-2011 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号