BS EN 50550:2011
家用和类似用途的工频过电压保护装置(POP)

Power frequency overvoltage protective device for household and similar applications (POP)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS EN 50550:2011 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
BS EN 50550:2011
发布
2011年
发布单位
英国标准学会
替代标准
BS EN 50550:2011+A1:2014
当前最新
BS EN 50550:2011+A1:2014
 
 
引用标准
EN 50160:2010 EN 55014-1:2006 EN 55022:2010 EN 60065:2002 EN 60384-14 EN 60664-1:2007 EN 60664-3 EN 60898-1:2003 EN 60898-2:2006 EN 60998-2-3 EN 61000 EN 61008 EN 61009 EN 61009-1:2004 EN 61249-2 EN 61543:1995 EN 61558-1 EN 61558-2 EN ISO 306
适用范围
This European Standard applies to power frequency overvoltage protection devices (hereafter referred to as “POP”) for household and similar uses, with a rated frequency of 50 Hz, a rated voltage 230 V a.c. (between phase and neutral), intended to be used in combination with a main protective device being either a CB in compliance with EN 60898-1 or EN 60898-2, a RCCB in compliance with EN 61008-1 or a RCBO in compliance with EN 61009-1. NOTE 1 Requirements for POPs in combination with switching devices other than a main protective device, or a POP integrated in a MPD, are under consideration. NOTE 2 Requirements for POP with functional earth connection regarding temporary overvoltage withstand are under consideration. NOTE 3 A POP is not a protective device to be used for automatic disconnection of the supply in the meaning of HD 60364-4-41. They are intended for use in an environment with pollution degree 2 and overvoltage category III. They can be designed for factory assembly or for assembly on site. These devices are intended to mitigate the effects of power frequency overvoltages between phase and neutral conductor (e.g. caused by loss of neutral conductor in the three phase supply upstream the POP) for downstream equipment by actuating the main protective device when an overvoltage between phase and neutral is detected. NOTE 4 To mitigate means in this context that the POP will provide protection in most cases of power frequency overvoltages. NOTE 5 Protection in case of overvoltage between phases is under consideration. In case of phase to phase electrical supply system with rated voltage between phases 230 V a.c. and no neutral conductor, one line monitored POP in compliance to this standard can be used according to manufacturer’s instruction. The POP does not impair the protective function of the main protective device. This European Standard does not apply for protection against common mode over voltages. This European Standard does not apply to surge protective devices. This European Standard states: – the definitions of terms used for POP (Clause 3); – the classification of POP (Clause 4); – the characteristics of POP (Clause 5); – the preferred values of the operating and influencing quantities (Clause 5); – the marking and information to be provided for POP (Clause 6); – the standard conditions for installation and operation in service (Clause 7); – the requirements for construction and operation (Clause 8); – the list of minimum requirements to be tested (Clause 9).

BS EN 50550:2011相似标准


推荐





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号