This Technical Specification specifies a method for the determination of bulk density of solid recovered fuels using a standard measuring container. This method is applicable to all solid recovered fuels with a nominal top size of maximal 100 mm.NOTE 1 The reason for the limitation to maximal 100 mm is the practical maximum volume of a measurement container and thus dimensions of the aperture of the container. Particle dimension should not exceed 1/3 of this value.NOTE 2 Bulk density of solid recovered fuels is subject to variation due to several impacts such as vibration, shock, pressure, biodegradation, drying and wetting. Measured bulk density can theref