Specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of vertically or horizontally oriented specimens made from plastic and other non-metallic materials, exposed to a small-flame ignition source of 50 W nominal power. These test methods determine the linear burning rate and the afterflame/afterglow times as well as the damaged length of specimens. They are applicable to solid and cellular materials that have an apparent density of not less than 250 Kg/m3, determined in accordance with ISO 845. They do not apply to materials that shrink away from the applied flame without igniting; ISO 9773 should be used for th