ASTM D7352-07(2012)
用薄膜界面探头 (MIP) 记录挥发性污染物用直推技术的标准实施规程

Standard Practice for Direct Push Technology for Volatile Contaminant Logging with the Membrane Interface Probe (MIP)


标准号
ASTM D7352-07(2012)
发布
2007年
发布单位
美国材料与试验协会
替代标准
ASTM D7352-18
当前最新
ASTM D7352-18
 
 
引用标准
ASTM D5299 ASTM D6001 ASTM D6282 ASTM D653 ASTM D6724 ASTM D6725 ASTM E355
适用范围
5. Significance and UseTop Bottom

5.1 The MIP system provides a timely and cost effective way (4) for delineation of volatile organic contaminants (for example, benzene, toluene, solvents, trichloroethylene, tetrachloroethylene) with depth (5, 6). Recent investigation (2) has found the MIP can be effective in locating zones where dense nonaqueous phase liquids (DNAPL) may be present. MIP provides real-time measurement for optimizing selection of sample locations when using a dynamic work plan. By identifying the depth at which a contaminant is located, a more representative sample of soil or water can be collected.

5.2 Correlation of a series of MIP logs across a site can provide 2-D and 3-D definition of the contaminant plume. When lithologic logs are obtained (EC, CPT, etc.) with the MIP data, contaminant migration pathways may be defined.

5.3 The MIP logs provide a detailed record of contaminant distribution in the saturated and unsaturated formations. A proportion of the chlorinated and non-chlorinated volatile organic contaminants in the sorbed, aqueous, or gaseous phases partition through the membrane for detection up hole.

5.4 The data obtained from application of this practice may be used to guide soil (Guide D6282) and groundwater sampling (Guide D6001) or placement of long-term monitoring wells (Guide D6724).

5.5 MIP data can be used to optimize site remediation by knowing the depth distribution of volatile organic contaminants. For example, materials injected for remediation are placed at correct depths in the formation.

5.6 This practice also may be used as a means of evaluating remediation performance. MIP can provide a cost-effective way to monitor the progress of remediation. When properly performed at suitable sites, logging locations can be compared from the initial investigation to the monitoring of the contaminant under remediation conditions.

Note 1???The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Practitioners that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results ......

ASTM D7352-07(2012)相似标准


推荐





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号