ASTM E2847-2013
宽带红外测温仪的校准和精度验证的标准实施规程

Standard Practice for ?Calibration and Accuracy Verification of Wideband Infrared Thermometers


ASTM E2847-2013 中,可能用到以下仪器设备

 

testo 845 红外测温仪

testo 845 红外测温仪

德图仪器国际贸易(上海)有限公司

 

testo t810红外测温仪

testo t810红外测温仪

德图仪器国际贸易(上海)有限公司

 

testo 810 红外测温仪

testo 810 红外测温仪

德图仪器国际贸易(上海)有限公司

 

德图 testo 720 - 测温仪

德图 testo 720 - 测温仪

德图仪器国际贸易(上海)有限公司

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM E2847-2013 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ASTM E2847-2013
发布日期
2013年
实施日期
废止日期
国际标准分类号
17.200.20 (Temperature-measuring instruments)
发布单位
美国材料与试验协会
适用范围

5.1x00a0;This guide provides guidelines and basic test methods for the accuracy verification of infrared thermometers. It includes test set-up and calculation of uncertainties. It is intended to provide the user with a consistent method, while remaining flexible in the choice of calibration equipment. It is understood that the uncertainty obtained depends in large part upon the apparatus and instrumentation used. Therefore, since this guide is not prescriptive in approach, it provides detailed instruction in uncertainty evaluation to accommodate the variety of apparatus and instrumentation that may be employed.

5.2x00a0;This guide is intended primarily for calibrating handheld infrared thermometers. However, the techniques described in this guide may also be appropriate for calibrating other classes of radiation thermometers. It may also be of help to those calibrating thermal imagers.

5.3x00a0;This guide specifies the necessary elements of the report of calibration for an infrared thermometer. The required elements are intended as a communication tool to help the end user of these instruments make accurate measurements. The elements also provide enough information, so that the results of the calibration can be reproduced in a separate laboratory.

1.1x00a0;This guide covers electronic instruments intended for measurement of temperature by detecting the intensity of thermal radiation exchanged between the subject of measurement and the sensor.

1.2x00a0;The devices covered by this guide are referred to as infrared thermometers in this document.

1.3x00a0;The infrared thermometers covered in this guide are instruments that are intended to measure temperatures below 1000x00b0;C, measure thermal radiation over a wide bandwidth in the infrared region, and are direct-reading in temperature.

1.4x00a0;This guide covers best practice in calibrating infrared thermometers. It addresses concerns that will help the user perform more accurate calibrations. It also provides a structure for calculation of uncertainties and reporting of calibration results to include uncertainty.

1.5x00a0;Details on the design and construction of infrared thermometers are not covered in this guide.

1.6x00a0;This guide does not cover infrared thermometry above 1000x00b0;C. It does not address the use of narrowband infrared thermometers or infrared thermometers that do not indicate temperature directly.

1.7x00a0;The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.8x00a0;The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.


ASTM E2847-2013 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号