ASTM F2998-2014
采用荧光显微法量化固定细胞扩散面积的指南

Guide for Using Fluorescence Microscopy to Quantify the Spread Area of Fixed Cells


ASTM F2998-2014 中,可能用到以下仪器设备

 

Luminex 200 液相芯片仪

Luminex 200 液相芯片仪

默克生命科学

 

Guava easyCyte 12系统

Guava easyCyte 12系统

默克生命科学

 

Guava easyCyte 6系统

Guava easyCyte 6系统

默克生命科学

 

Guava easyCyte 6HT系统

Guava easyCyte 6HT系统

默克生命科学

 

guava easyCyte 5系统

guava easyCyte 5系统

默克生命科学

 

Guava easyCyte 5HT系统

Guava easyCyte 5HT系统

默克生命科学

 

默克Millicell ERS-2 电阻仪

默克Millicell ERS-2 电阻仪

默克生命科学

 

Vectra™全自动定量病理学工作站(6片连载型)

Vectra™全自动定量病理学工作站(6片连载型)

珀金埃尔默企业管理(上海)有限公司PerkinElmer

 

Vectra™全自动定量病理学工作站200片连载型

Vectra™全自动定量病理学工作站200片连载型

珀金埃尔默企业管理(上海)有限公司PerkinElmer

 

赛默飞Attune NxT声波聚焦流式细胞仪

赛默飞Attune NxT声波聚焦流式细胞仪

赛默飞 AppliedBiosystems

 

autoMACS Pro 全自动磁性细胞分选仪

autoMACS Pro 全自动磁性细胞分选仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® Tyto 流式细胞分选仪

MACSQuant® Tyto 流式细胞分选仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

美天旎MACSQuant® X高通量流式细胞仪

美天旎MACSQuant® X高通量流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® 流式细胞仪

MACSQuant® 流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® VYB流式细胞仪

MACSQuant® VYB流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

ClonePix 2细胞克隆筛选系统

ClonePix 2细胞克隆筛选系统

美谷分子仪器(上海)有限公司

 

皮升泵LPP01-100(细胞注射器)-LongerPump

皮升泵LPP01-100(细胞注射器)-LongerPump

保定兰格恒流泵有限公司

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM F2998-2014 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ASTM F2998-2014
发布日期
2014年
实施日期
废止日期
国际标准分类号
07.080 (Biology. Botany. Zoology); 07.100.01 (Micr
发布单位
US-ASTM
适用范围

5.1x00a0;Under well-controlled conditions, the quantitative evaluation of morphological features of a cell population can be used to identify changes in cellular behavior or state. Cell morphology changes may be expected when, for example, there is a response to changes in cellular cytoskeleton organization (1), a response of cells to toxic compounds, changes in differentiation state, and changes in adhesion properties of cells to a substrate by either chemical or mechanical-induced extracellular matrix-based (ECM-based) signaling pathways (2, 3). Typically, populations of cells exhibit a range of morphologies even when the cells are genetically identical and are in a homogeneous environment (4). This biological variation in cell response is due to both cell-cycle variations and stochasticity in the cellular reactions that control adhesion and spreading in cells. By using cell-by-cell, microscopy-based measurements and appropriate statistical sampling procedures, the distribution of cell morphologies such as cell spreading area per cell can be measured. This distribution is highly characteristic of the culture and conditions being examined.

5.2x00a0;It is important to note that the use of this technique for cells on or in a 3-D scaffold materials can complicate the interpretation of the data. The topographic transforms of the cells on a 3-D material may require full volumetric imaging and not just wide-field fluorescence imaging as described here.

5.3x00a0;the following are several examples of how this measurement can be used in a laboratory:x2014;

5.3.1x00a0;Quantify Cellular Response to a Biomaterialx2014;The measurement of cell spread area can be used to characterize the response of cells to biomaterials. For example, spreading of most cell types is extremely sensitive to the stiffness of the culture substrate (5), (6). It is important to note that cell response to an ECM may be dependent on the preparation of the matrix. For example, the same ECM proteins prepared in a fibrillar or non-fibrillar surface coating can result in different morphology response

5.3.2x00a0;Quality Control Metric for General Cell Culture Conditionsx2014;Cell spread area may be a useful metric for monitoring a change in cell culture conditions (that is, due to a serum component, pH, passage number, confluence, etc.). Cell morphology is often altered when cells are stressed and proceeding through cell-death related processes (that is, apotoposis).

5.3.3x00a0;Quality Control Metric for Biomaterial Fabricationx2014;Cell spread area measurements may be useful for generating specifications for a biomaterial. These specifications may stipulate how a particular cell line responds to a fabricated biomaterial.

5.3.4x00a0;Quality Control Metric for Cell Line Integrity and Morphology Benchmarkingx2014;The morphology characteristic of a cell line grown under specified conditions should ideally be the same over time and in different laboratories. Thus, cell spread area measurements may be useful for validating that no significant changes in the cell cultures have occurred. This measurement provides a benchmark that is useful for establishing the current state of the cell culture and a metric that can be charted to increased confidence for within and between laboratory comparisons of cellular measurements (7......