BS 7967-2015
用于测量住宅内一氧化碳和家用燃气器具燃烧性能的便携式电子燃烧气体分析仪使用指南

Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fired appliances


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS 7967-2015 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
BS 7967-2015
发布日期
2015年02月28日
实施日期
2015年02月28日
废止日期
中国标准分类号
Q82
国际标准分类号
13.040.40;97.100.20
发布单位
GB-BSI
适用范围
1.1This standard provides guidance for gas operatives on: a)the general use of an electronic portable combustion gas analyser conforming to BS EN 50379-3 and BS 7927:1998 incorporating Amendment No.1:1999; NOTE 1 This standard assumes that a portable combustion gas analyser [often referred to colloquially as a "flue gas analyser" (FGA)J of the type specified in BS EN 50379-3 or BS 7927:1998 incorporating Amendment No. 1:1999 is available to the gas operative and the operative is competent in its use and the interpretation of any reading obtained. This competence can be demonstrated by satisfactory completion of the relevant ACS assessments,which cover the use of electronic portable combustion gas analysers. See Clause 4 for further information on competence. NOTE 2 BS EN 50379-3 superseded BS 7927:1998 incorporating Amendment No. 1:1999 on I March 2007. However,electronic portable combustion gas analysers conforming to BS 7927:1998 incorporating Amendment No. 1:1999 remain acceptable for the purposes of this standard. b)the use of such an electronic portable combustion gas analyser to determine ambient levels of carbon monoxide (CO) and, in certain circumstances (see Notes 4 and 5, and Commentary on 8.1), detect the presence of carbon dioxide (CO) in dwellings; NOTE 3 A definition of a dwelling is given in 3.7. NOTE 4 One of the main combustion products from gas appliances is CO, which is mainly regarded as an asphyxiant, but is also a toxic substancc which could be present in the air in sufficient quantity to prove harmful. For guidance on the occupational health considerations of CO, reference can be made to the HSE Guidance note on Workplace exposure limits,EH4012005 [8]. NOTE 5 Electronic portable combustion gas analysers that calculate CO levels from an oxygen (O) measurement are: ?well proven for calculating CO levels in combustion gases in the flue of an appliance; ?not suitable for measuring ambient levels of CO in dwellings; and ?able to detect increases in the ambient CO levels in ambient atmospheres and such increases in CO will provide an early indication of increasing build-up of products of combustion in the room (see Commentary on 8.1). c)the use of an electronic portable combustion gas analyser to measure CO and CO in combustion products from the following types of gas-fired appliances: 1)flueless appliances (type A appliances); 2)open-flue appliances (type B appliances); 3)room-sealed appliances (type C appliances); and 4)all appliances for which the gas appliance manufacturer has provided a purpose-designed sampling point or specific sampling instructions; NOTE 6 Type A, type B and type C classification of gas-fired appliances is described in PD CENITR 1749 and in 3.21. d)the use of an electronic portable combustion gas analyser as a diagnostic instrument to assist a gas operative: 1)in confirming safe and/or efficient operation at the time of commissioning, in accordance with gas appliance instructions; 2)in determining the level of servicing required for a gas-fired appliance;




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号