5.1 It is important to recognize that the results obtained by this test method or any other method for particle size determination utilizing different physical principles may disagree. The results are strongly influenced by physical principles employed by each method of particle size analysis. The results of any particle sizing method should be used only in a relative sense and should not be regarded as absolute when comparing results obtained by other methods. Particularly for fine materials (that is, average particle size < 20 μm), significant differences are often observed for laser light scattering instruments of different manufacturers. These differences include lasers of different wavelengths, detector configuration, and the algorithms used to convert scattering to particle size distribution. Therefore, comparison of results from different instruments may be misleading.3
5.2 Light scattering theories (Fraunhofer Diffraction4 and Mie Scattering5) that are used for determination of particle size have been available for many years. Several manufacturers of testing equipment now have units based on these principles. Although each type of testing equipment utilizes the same basic principles for light scattering as a function of particle size, different assumptions pertinent to application of the theory and different models for converting light measurements to particle size, may lead to different results for each instrument. Furthermore, any particles which are outside the size measurement range of the instrument will be ignored, causing an increase in the reported percentages within the detectable range. A particle size distribution which ends abruptly at the detection limit of the instrument may indicate that particles outside the range are present. Therefore, use of this test method cannot guarantee directly comparable results from different types of instruments.
5.3 This test method can be used to determine particle size distributions of catalysts, supports, and catalytic raw materials for specifications, manufacturing control, and research and development work.
5.4 For fine materials (that is, average particle size < 20 μm), it is critical that Mie Scattering Theory be applied. This involves entering an “optical model” consisting of the “real” and “imaginary” refractive indices of the solid at the wavelength of the laser. The “imaginary” refractive index is also referred to as the “absorbance,” as it has a value of zero for transparent materials such as glass beads. For common materials and naturally occurring minerals (for example, kaolin), these values are known and published, and usually included in the manufacturer’s instrument manual (for example, as an appendix). For example, kaolinite measured at 589.3 nm has a “real” refractive index of 1.55. The absorbance (imaginary component) for minerals and metal oxides is normally taken as 0.001, 0.01 or 0.1. Many of the published values were measured at 589.3 nm (sodium light) but often values at other wavelengths are also given. Extrapolation, interpolation, or estimation to the wavelength of the laser being used can therefore be made.6
......
ASTM C1070-2001(2007) 用激光扩散法测定氧化铝和石英粒度分布的试验方法 ASTM D4464-2000(2005) 激光散射测定催化材料粒度分布的标准试验方法 ASTM D4464-2000 激光散射测定催化材料粒度分布的标准试验方法 行业标准-有色金属,关于激光粒度仪仪器方法的标准 YS/T 617.7-2007 铝、镁及其合金粉理化性能测定方法...
药粉激光粒度仪除了测量药粉的粒径及粒度分布外,还广泛应用于具有高要求的水泥、陶瓷、药品、涂料、染料、颜料、填料、化工产品、催化剂、煤粉、泥砂、粉尘、面粉、食品、添加剂、农药、石墨、感光材料、燃料、金属与非金属粉末、碳酸钙、高岭土、水煤浆及其他粉体行业。 激光粒度仪作为一种新型的粒度测试仪器,已经在粉体加工、应用与研究领域得到广泛的应用。...
粒度仪是用物理的方法测试固体颗粒的大小和分布的一种仪器。根据测试原理的不同分为沉降式粒度仪、沉降天平、激光粒度仪、光学颗粒计数器、电阻式颗粒计数器、颗粒图像分析仪等。激光粒度仪是通过激光散射的方法来测量悬浮液,乳液和粉末样品颗粒分布的多用途仪器 。具有测试范围宽、测试速度快、结果准确可靠、重复性好、操作简便等突出特点,是集激光技术、计算机技术、光电子技术于一体的新一代粒度测试仪器。...
湿法激光粒度仪采用醉优的非均匀叉三维扇形矩阵排列的探测器阵列和合理的粒度分级,从而能够准确地测量颗粒群的粒度分布。 适用于建材、冶金化工、煤炭矿产、医药农药、保健品、陶瓷磨料、颜料染料、油漆涂料、催化剂、锂电池材料、硅酸盐、水处理、贵金属等领域的粒度分析测试。 标签: 湿法激光粒度仪...