WARNING: Personnel applying this standard should have practical experience in formal laboratory work. This section does not address all possible security issues. It is the user's responsibility to take appropriate safety and health measures and ensure compliance with the conditions stipulated in the relevant national laws and regulations. This part specifies the perchloric acid gravimetric method for the determination of silicon content in metallic chromium. This section applies to the determination of silicon content in chromium metal. Measuring range (mass fraction): 0.10% to 0.50%.
GB/T 4702.2-2008 Referenced Document
GB/T 4010 Ferroallys sampling and preparation of samples for chemical analysis*, 2015-09-11 Update
GB/T 4702.2-2008 history
2008GB/T 4702.2-2008 Chromium metal. Determination of silicon content. The perchloric acid gravimetric method
1984GB/T 4702.2-1984 Methods for chemical analysis of chromium metal--The perchloric acid dehydration-gravimetric method for the determination of silicon content