GB 4824-2004
Industrial,scientific and medical(ISM)radio-frequency equipment-Electromagnetic disturbance characteristics-Limits and methods of measurement (English Version)

GB 4824-2004
Standard No.
GB 4824-2004
Language
Chinese, Available in English version
Release Date
2004
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2015-01
Replace By
GB 4824-2013
Latest
GB 4824-2019
Replace
GB 4824-2001
Scope
This standard specifies the limits and measurement methods for the electromagnetic disturbance characteristics of industrial, scientific and medical (ISM) equipment (hereinafter referred to as ISM equipment) and electrical discharge machining (EDM) and arc welding equipment defined in Chapter 2. Note: The limit values in this standard are formulated on the basis of considering the probability of interference that may occur. If interference occurs, additional suppression measures are required. This standard specifies the limits and measurement methods of radio frequency disturbances within the frequency range of 9 kHz to 400 GHz. This standard also applies to ISM lighting equipment operating in the ISM frequency bands 2.45 GHz and 5.8 GHz. See the provisions of GB l7743 for the requirements of other types of lighting equipment. 1.2 Normative references The clauses in the following documents become the clauses of this standard through the reference of this standard. For dated references, all subsequent amendments (excluding errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement based on this standard to study whether the latest versions of these documents can be used . For undated references, the latest version applies to this standard. GB/T 4365 Electromagnetic Compatibility Terminology (GB/T 4365--2003, idt IEC 60050(161)). GB l002 Household and similar single-phase plug and socket type, basic parameters and dimensions (GB l002--1996, idt IEC60083) GB/T 6113.2-1998 Radio disturbance and immunity measurement method (eqv CISPRl6-2:1996) GB/T T 16607 Measurement method of radiated disturbance of microwave oven above 1 GHz (GB/T 16607-1996, eqv CISPR19) GB 17743 Limits and measurement methods of radio disturbance characteristics of electric lighting and similar equipment (GB/T 17743-1999, idtCSPR15) IEC 60705:1999 Household Microwave Ovens—Measuring Methods for Performance IEC 60974—10 Arc Welding Equipment—Part 10 Electromagnetic Compatibility Requirements IEC 61689:1996 Performance Requirements and Measurement Methods for Ultrasonic Physiotherapy Systems with a Frequency Range of 0.5 to 5 MHz CISPR16 —1:1999 Specification for Radio Disturbance and Immunity Measuring Equipment

GB 4824-2004 history

  • 2019 GB 4824-2019 Industrial,scientific and medical equipment—Radio-frequency disturbance characteristics—Limits and methods of measurement
  • 2013 GB 4824-2013 Industrial,scientific and medical (ISM) radio-frequency equipment.Disturbance characteristics.Limits and methods of measurement
  • 2004 GB 4824-2004 Industrial,scientific and medical(ISM)radio-frequency equipment-Electromagnetic disturbance characteristics-Limits and methods of measurement
  • 2001 GB 4824-2001 Industrial,scientific and medical(ISM) radio-frequency equipment-Electromagnetic disturbance characteristics-Limits and methods of measurement