ZH

RU

ES

icp metal element

icp metal element, Total:499 items.

In the international standard classification, icp metal element involves: Jewellery, Animal feeding stuffs, Non-ferrous metals, Analytical chemistry, Nuclear energy engineering, Powder metallurgy, Power stations in general, Products of the chemical industry, Organic chemicals, Paint ingredients, Materials for the reinforcement of composites, Water quality, Inorganic chemicals, Fuels, Products of non-ferrous metals, Metalliferous minerals, Rubber, Lamps and related equipment, Farming and forestry, Raw materials for rubber and plastics, Construction materials, Testing of metals, Materials for aerospace construction, Ferrous metals, Vocabularies, Plastics, Wastes, Wood-based panels, Resistors, Rubber and plastics products, Medical equipment, Electrical accessories, Soil quality. Pedology, Industrial furnaces, Elements of buildings, Fertilizers, General methods of tests and analysis for food products, Meat, meat products and other animal produce, Lubricants, industrial oils and related products, Environmental protection, Fruits. Vegetables, Manufacturing forming processes, Aircraft and space vehicles in general, Ceramics, Information sciences. Publishing, Character sets and information coding, Fishing and fish breeding, Applications of information technology, Edible oils and fats. Oilseeds, Coals, Thermodynamics and temperature measurements, Domestic, commercial and industrial heating appliances, Insulating fluids, Physics. Chemistry, Pharmaceutics, Corrosion of metals, Electrical engineering in general, Electronic components in general, Semiconducting materials, Petroleum products in general, Glass, Iron and steel products, Interior finishing, Road vehicle systems.


International Organization for Standardization (ISO), icp metal element

  • ISO 11495:2019 Jewellery and precious metals — Determination of palladium in palladium alloys — ICP-OES method using an internal standard element
  • ISO 11494:2014 Jewellery - Determination of platinum in platinum jewellery alloys - ICP-OES method using yttrium as internal standard element
  • ISO 11495:2014 Jewellery - Determination of palladium in palladium jewellery alloys - ICP-OES method using yttrium as internal standard element
  • ISO 2092:1981 Light metals and their alloys; Code of designation based on chemical symbols
  • ISO 19050:2021 Rubber, raw, vulcanized — Determination of metal content by ICP-OES
  • ISO 4883:1978 Hardmetals; Determination of contents of metallic elements by X-ray fluorescence; Solution method
  • ISO 4503:1978 Hardmetals; Determination of contents of metallic elements by X-ray fluorescense; Fusion method
  • ISO 11494:2019 Jewellery and precious metals — Determination of platinum in platinum alloys — ICP-OES method using an internal standard element
  • ISO/DIS 5724 Jewellery and precious metals — Determination of very high purity gold — Difference method using ICP-MS
  • ISO/PRF 5724:2023 Jewellery and precious metals — Determination of very high purity gold — Difference method using ICP-MS
  • ISO 5724:2023 Jewellery and precious metals — Determination of very high purity gold — Difference method using ICP-MS
  • ISO/TS 16965:2013 Soil quality.Determination of trace elements using inductively coupled plasma mass spectrometry (ICP-MS)
  • ISO 15096:2020 Jewellery and precious metals — Determination of high purity silver — Difference method using ICP-OES
  • ISO 15093:2020 Jewellery and precious metals — Determination of high purity gold, platinum and palladium — Difference method using ICP-OES
  • ISO 11885:2007 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
  • ISO 17294-2:2016 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
  • ISO/CD 16965:2023 Environmental solid matrices — Determination of trace elements using inductively coupled plasma mass spectrometry (ICP-MS)
  • ISO/FDIS 22036:2023 Environmental solid matrices — Determination of elements using inductively coupled plasma optical emission spectrometry (ICP-OES)
  • ISO 5755-2:1987 Sintered metal materials; Specifications; Part 2 : Sintered iron and sintered steel containing one or both of the elements carbon and copper, used for structural parts
  • ISO 11494:2008 Jewellery - Determination of platinum in platinum jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element
  • ISO 11495:2008 Jewellery - Determination of palladium in palladium jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element
  • ISO 3110:1975 Copper alloys; Determination of aluminium as alloying element; Volumetric method
  • ISO 3111:1975 Copper alloys; Determination of tin as alloying element; Volumetric method
  • ISO 17294-2:2003 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of 62 elements
  • ISO 21033:2016 Animal and vegetable fats and oils - Determination of trace elements by inductively coupled plasma optical emission spectroscopy (ICP-OES)
  • ISO/FDIS 17294-2 Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of selected elements including uranium isotopes
  • ISO 17294-2:2011 Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of selected elements including uranium isotopes
  • ISO 17294-2:2023 Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of selected elements including uranium isotopes
  • ISO/TS 21033:2011 Animal and vegetable fats and oils — Determination of trace elements by inductively coupled plasma optical emission spectroscopy (ICP-OES)
  • ISO 24047:2021 Plastics - Polyethylene (PE) and polypropylene (PP) thermoplastics - Determination of metal content by ICP-OES

ES-UNE, icp metal element

  • UNE-EN ISO 11494:2019 Jewellery and precious metals - Determination of platinum in platinum alloys - ICP-OES method using an internal standard element (ISO 11494:2019) (Endorsed by Asociación Española de Normalización in November of 2019.)
  • UNE-EN ISO 11495:2019 Jewellery and precious metals - Determination of palladium in palladium alloys - ICP-OES method using an internal standard element (ISO 11495:2019) (Endorsed by Asociación Española de Normalización in November of 2019.)
  • UNE-EN 17053:2018 Animal feeding stuffs: Methods of sampling and analysis - Determination of trace elements, heavy metals and other elements in feed by ICP-MS (multi-method)
  • UNE-EN 24503:1993 HARDMETALS. DETERMINATION OF CONTENT OF METALLOC ELEMENTS BY X-RAY FLUORENSCENCE. FUSION METHOD (Endorsed by AENOR in May of 1993.)
  • UNE-EN 24883:1993 HARDMETALS. DETERMINATION OF CONTENTS OF METALLIC ELEMENTS BY X-RAY FLUORESCENCE. SOLUTION METHOD. (Endorsed by AENOR in May of 1993.)
  • UNE-CEN/TS 17774:2022 Organic and organo-mineral fertilizers - Determination of the content of specific elements by ICP-AES after extraction by water (Endorsed by Asociación Española de Normalización in May of 2022.)
  • UNE-EN 16801:2016 Foodstuffs - Determination of elements and their chemical species - Determination of methylmercury in foodstuffs of marine origin by isotope dilution GC-ICP-MS
  • UNE-EN 12938:1999 Methods for the analysis of pewter - Determination of alloying and impurity element contents by atomic spectrometry
  • UNE-CEN/TS 17770:2022 Organic and organo-mineral fertilizers - Determination of the total content of specific elements by ICP-AES after digestion by aqua regia (Endorsed by Asociación Española de Normalización in May of 2022.)
  • UNE-EN ISO 17294-2:2017 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes (ISO 17294-2:2016)
  • UNE-EN 17264:2020 Foodstuffs - Determination of elements and their chemical species - Determination of aluminium by inductively coupled plasma mass spectrometry (ICP-MS)
  • UNE-EN 16171:2016 Sludge, treated biowaste and soil - Determination of elements using inductively coupled plasma mass spectrometry (ICP-MS) (Endorsed by AENOR in December of 2016.)
  • UNE-EN 61152:1993 DIMENSIONS OF METAL-SHEATHED THERMOMETER ELEMENTS. (Endorsed by AENOR in April of 1996.)

German Institute for Standardization, icp metal element

  • DIN EN ISO 11494:2019-12 Jewellery and precious metals - Determination of platinum in platinum alloys - ICP-OES method using an internal standard element (ISO 11494:2019); German version EN ISO 11494:2019
  • DIN EN ISO 11495:2019 Jewellery and precious metals - Determination of palladium in palladium alloys - ICP-OES method using an internal standard element (ISO 11495:2019)
  • DIN EN ISO 11494:2019 Jewellery and precious metals - Determination of platinum in platinum alloys - ICP-OES method using an internal standard element (ISO 11494:2019)
  • DIN EN ISO 11495:2019-12 Jewellery and precious metals - Determination of palladium in palladium alloys - ICP-OES method using an internal standard element (ISO 11495:2019); German version EN ISO 11495:2019
  • DIN EN 17053:2018 Animal feeding stuffs - Methods of sampling and analysis - Determination of trace elements, heavy metals and other elements in feed by ICP-MS (multi-method)
  • DIN EN 17053:2018-03 Animal feeding stuffs - Methods of sampling and analysis - Determination of trace elements, heavy metals and other elements in feed by ICP-MS (multi-method); German version EN 17053:2018
  • DIN ISO 4503:1991 Hardmetals; determination of contents of metallic elements by x-ray fluorescence; fusion method; identical with ISO 4503:1978
  • DIN 22022-2:2001 Solid fuels - Determination of contents of trace elements - Part 2: ICP-OES
  • DIN 22022-7:2014 Solid fuels - Determination of contents of trace elements - Part 7: ICP-MS
  • DIN 22022-7:2014-07 Solid fuels - Determination of contents of trace elements - Part 7: ICP-MS
  • DIN 22022-2:2001-02 Solid fuels - Determination of contents of trace elements - Part 2: ICP-OES
  • DIN ISO 4883:1991 Hardmetals; determination of contents of metallic elements by X-ray fluorescence; solution method; identical with ISO 4883:1978
  • DIN V 65579:1991 Aerospace; carbon fibres; chemical analysis; determination of the metalloid elements
  • DIN 50451-3:2014-11 Testing of materials for semiconductor technology - Determination of traces of elements in liquids - Part 3: Determination of 31 elements in high-purity nitric acid by ICP-MS
  • DIN 50451-7:2018-04 Testing of materials for semiconductor technology - Determination of traces of elements in liquids - Part 7: Determination of 31 elements in high-purity hydrochloric acid by ICP-MS
  • DIN EN 15111:2007-06 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry); German version EN 15111:2007
  • DIN CEN/TS 17774:2022-07 Organic and organo-mineral fertilizers - Determination of the content of specific elements by ICP-AES after extraction by water; German version CEN/TS 17774:2022
  • DIN EN ISO 11494:2016 Jewellery - Determination of platinum in platinum jewellery alloys - ICP-OES method using yttrium as internal standard element (ISO 11494:2014); German version EN ISO 11494:2016
  • DIN EN ISO 11495:2016 Jewellery - Determination of palladium in palladium jewellery alloys - ICP-OES method using yttrium as internal standard element (ISO 11495:2014); German version EN ISO 11495:2016
  • DIN ISO 4503:1991-07 Hardmetals; determination of contents of metallic elements by x-ray fluorescence; fusion method; identical with ISO 4503:1978
  • DIN EN 61167:2012 Metal halide lamps - Performance specification (IEC 61167:2011); German version EN 61167:2011
  • DIN CEN/TS 17770:2022-07 Organic and organo-mineral fertilizers - Determination of the total content of specific elements by ICP-AES after digestion by aqua regia; German version CEN/TS 17770:2022
  • DIN EN 16801:2016-07 Foodstuffs - Determination of elements and their chemical species - Determination of methylmercury in foodstuffs of marine origin by isotope dilution GC-ICP-MS; German Version EN 16801:2016
  • DIN ISO 4883:1991-06 Hardmetals; determination of contents of metallic elements by X-ray fluorescence; solution method; identical with ISO 4883:1978
  • DIN EN 12938:2000-10 Methods for the analysis of pewter - Determination of alloying and impurity element contents by atomic spectrometry (includes AC:2000); German version EN 12938:1999 + AC:2000
  • DIN EN 15111:2007 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry); German version EN 15111:2007
  • DIN EN ISO 11885:2009 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (ISO 11885:2007)
  • DIN 4000-192:2023-05 Tabular layouts of properties - Part 192: Positioning elements
  • DIN 4000-191:2021-06 Tabular layouts of properties - Part 191: Clamping elements
  • DIN EN ISO 17294-2:2005 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of 62 elements (ISO 17294-2:2003); German version EN ISO 17294-2:2004
  • DIN EN 15763:2010 Foodstuffs - Determination of trace elements - Determination of arsenic, cadmium, mercury and lead in foodstuffs by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion; German version EN 15763:2009
  • DIN 44921-3:1985 Electric cartridge-type heating elements, metal-sheathed; requirements
  • DIN 44921-1:1985 Electric cartridge-type heating elements, metal-sheathed; dimensions
  • DIN 50451-4:2007-02 Testing of materials for semiconductor technology - Determination of trace elements in liquids - Part 4: Determination of 34 elements in ultra pure water by mass spectrometry with inductively coupled plasma (ICP-MS)
  • DIN EN 17264:2019 Foodstuffs - Determination of elements and their chemical species - Determination of aluminium by inductively coupled plasma mass spectrometry (ICP-MS)
  • DIN EN 17264:2019-11 Foodstuffs - Determination of elements and their chemical species - Determination of aluminium by inductively coupled plasma mass spectrometry (ICP-MS); German version EN 17264:2019
  • DIN EN ISO 17294-2:2017-01 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes (ISO 17294-2:2016); German version EN ISO 17294-2:2016 / Note: To be replaced by DIN EN ISO 172...
  • DIN EN 61152:1994 Dimensions of metal-sheathed thermometers elements (IEC 61152:1992, modified); German version EN 61152:1994
  • DIN 50451-3:2014 Testing of materials for semiconductor technology - Determination of traces of elements in liquids - Part 3: Determination of 31 elements in high-purity nitric acid by ICP-MS
  • DIN EN 15765:2010-04 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion; German version EN 15765:2009
  • DIN EN 16171:2017-01 Sludge, treated biowaste and soil - Determination of elements using inductively coupled plasma mass spectrometry (ICP-MS); German version EN 16171:2016

HU-MSZT, icp metal element

Military Standard of the People's Republic of China-General Armament Department, icp metal element

  • GJB 950.8-1990 Trace element analysis method of precious metals and their alloys ICP-AES method for determination of trace amounts of palladium and rhodium in platinum alloys
  • GJB 950.1-1990 Analysis method of trace elements of precious metals and their alloys ICP-AES method Determination of trace amounts of lead, antimony, bismuth and iron in gold and gold alloys
  • GJB 950.2-1990 Analysis method of trace elements of precious metals and their alloys ICP-AES method Determination of trace amounts of iron, lead, antimony and bismuth in silver and silver alloys
  • GJB 3419-1998 Method for determination of density and impurity elements of depleted uranium metal ingots
  • GJB 9254-2017 Determination method of mass concentration of neodymium element in neodymium phosphate glass ICP-AES method
  • GJB 2435-1995 Basic attributes of military data elements
  • GJB 770.201-1989 Test methods for gunpowder analysis Determination of metal element content Atomic absorption spectrometry
  • GJB 950.5-1990 Analysis method of trace elements of precious metals and their alloys. Determination of trace iron in palladium alloys by sulfosalic acid photometric method.
  • GJB 950.5A-2021 Methods for analysis of trace elements of precious metals and their alloys Part 5: Determination of trace iron in palladium alloys by sulfosalicylic acid photometric method
  • GJB 950.7-1990 Analysis method of trace elements of precious metals and their alloys. Determination of trace amounts of lead, antimony and bismuth in palladium alloys by graphite furnace atomic absorption spectrometry.
  • GJB 950.6-1990 Analysis method of trace elements of precious metals and their alloys Separation of phenanthroline by hydrazine sulfate Photometric method for determination of trace iron in palladium alloys
  • GJB 950.3-1990 Analysis methods for trace elements of precious metals and their alloys. Organic solvent extraction and malachite green photometric method for determination of trace amounts of gold in platinum and platinum and palladium alloys.

Association Francaise de Normalisation, icp metal element

  • NF V18-247*NF EN 17053:2018 Animal feeding stuffs: Methods of sampling and analysis - Determination of trace elements, heavy metals and other elements in feed by ICP-MS (multi-method)
  • NF EN ISO 21392:2021 Cosmétiques - Méthodes d'analyse - Mesurage des éléments traces métalliques par ICP-MS dans les produits cosmétiques finis
  • NF EN 17053:2018 Aliments des animaux - Méthodes d'échantillonnage et d'analyse - Dosage par ICP-MS (multiméthode) des éléments traces, métaux lourds et autres éléments inorganiques présents dans les aliments
  • NF EN 24503:1993 Métaux-durs - Dosage des éléments métalliques par fluorescence de rayons X - Méthode par fusion.
  • NF A06-206:2015 Jewellery - Determination of platinum in platinum jewellery alloys - ICP-OES method using yttrium as internal standard element
  • NF EN 24883:1993 Métaux-durs - Dosage des éléments métalliques par fluorescence de rayons X - Méthode par solution.
  • NF T25-112:2011 Carbon fibers - Chemical analysis - Determination of the metalloid elements.
  • NF A95-491*NF EN 24503:1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Fusion method.
  • NF A95-490*NF EN 24883:1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Solution method.
  • NF EN 13507:2018 Projection thermique - Traitement préalable de surface de pièces et éléments métalliques pour projection thermique
  • XP CEN/TS 17774:2022 Engrais organiques et organo-minéraux - Détermination de la teneur en éléments spécifiques par ICP-AES après extraction à l'eau
  • NF EN ISO 11885:2009 Qualité de l'eau - Dosage d'éléments choisis par spectroscopie d'émission optique avec plasma induit par haute fréquence (ICP-OES)
  • NF T90-136*NF EN ISO 11885:2009 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES).
  • XP U42-705*XP CEN/TS 17774:2022 Organic and organo-mineral fertilizers - Determination of the content of specific elements by ICP-AES after extraction by water
  • XP CEN/TS 17770:2022 Engrais organiques et organo-minéraux - Détermination de la teneur totale en éléments spécifiques par ICP-AES après digestion à l'eau régale
  • NF A06-210*NF ISO 15096:2020 Jewellery and precious metals - Determination of high purity silver - Difference method using ICP OES
  • NF V03-064*NF EN 15763:2010 Foodstuffs - Determination of trace elements - Determination of arsenic, cadmium, mercury and lead in foodstuffs by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion.
  • NF A06-209:2015 Jewellery - Determination of precious metals in 999 %o gold platinum and palladium jewellery alloys - Difference method using ICP OES
  • XP U42-704*XP CEN/TS 17770:2022 Organic and organo-mineral fertilizers - Determination of the total content of specific elements by ICP-AES after digestion by aqua regia
  • NF A06-902*NF EN 12938:2000 Methods for the analysis of pewter - Determination of alloying and impurity element contents by atomic spectrometry.
  • NF P34-211:1987
  • NF V03-098*NF EN 15111:2007 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry).
  • NF T60-230*NF ISO 21033:2016 Animal and vegetable fats and oils - Determination of trace elements by inductively coupled plasma optical emission spectroscopy (ICP-OES)
  • NF V03-171*NF EN 16801:2016 Foodstuffs - Determination of elements and their chemical species - Determination of methylmercury in foodstuffs of marine origin by isotope dilution GC-ICP-MS
  • NF EN 16801:2016 Produits alimentaires - Détermination des éléments et de leurs espèces chimiques - Détermination de la teneur en méthylmercure dans les produits alimentaires d'origine marine par dilution isotopique CG-ICP-SM
  • NF T90-164:2005 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2 : determination of 62 elements.
  • NF EN ISO 17294-2:2016 Qualité de l'eau - Application de la spectrométrie de masse avec plasma à couplage inductif (ICP-MS) - Partie 2 : dosage des éléments sélectionnés y compris les isotopes d'uranium
  • NF T90-164*NF EN ISO 17294-2:2016 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2 : determination of selected elements including uranium isotopes
  • NF EN 15765:2010 Produits alimentaires - Dosage des éléments traces - Dosage de l'étain par spectrométrie de masse à plasma induit par haute fréquence (ICP-MS) après digestion sous pression
  • NF EN 61152:1994 Dimensions des éléments thermométriques sous gaine métallique
  • NF V03-066*NF EN 15765:2010 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion.
  • NF V03-264*NF EN 17264:2019 Foodstuffs - Determination of elements and their chemical species - Determination of aluminium by inductively coupled plasma mass spectrometry (ICP-MS)
  • NF EN 15111:2007 Produits alimentaires - Dosage des éléments traces - Dosage de l'iode par spectrométrie d'émission avec plasma induit par haute fréquence et spectromètre de masse (ICP-SM)
  • NF EN 17264:2019 Produits alimentaires - Dosage des éléments et de leurs espèces chimiques - Dosage de l'aluminium par spectrométrie de masse avec plasma à couplage inductif (ICP-MS)
  • NF X31-042*NF EN 16171:2016 Sludge, treated biowaste and soil - Determination of elements using inductively coupled plasma mass spectrometry (ICP-MS)
  • NF EN 16171:2016 Boues, bio-déchets traités et sols - Détermination des éléments en traces par spectrométrie de masse avec plasma induit par haute fréquence (ICP-MS)
  • NF D63-006*NF EN 12149:1997 Wall coverings in roll form. Determination of migration of heavy metals and certain other elements, of vinyl chloride monomer and of formaldehyde release.
  • NF C05-100-4/A1*NF EN 62321-4/A1:2017 Determination of certain substances in electrotechnical products - Part 4 : mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS

British Standards Institution (BSI), icp metal element

  • BS EN 17053:2018 Animal feeding stuffs: Methods of sampling and analysis. Determination of trace elements, heavy metals and other elements in feed by ICP-MS (multi-method)
  • BS EN ISO 11494:2019 Tracked Changes. Jewellery and precious metals. Determination of platinum in platinum alloys. ICP-OES method using an internal standard element
  • BS EN ISO 11495:2019 Tracked Changes. Jewellery and precious metals. Determination of palladium in palladium alloys. ICP-OES method using an internal standard element
  • BS EN 24503:1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Fusion method
  • BS ISO 11494:2014 Jewellery. Determination of platinum in platinum jewellery alloys. ICP-OES method using yttrium as internal standard element
  • BS ISO 11495:2014 Jewellery. Determination of palladium in palladium jewellery alloys. ICP-OES method using yttrium as internal standard element
  • BS ISO 19050:2015 Rubber, raw, vulcanized. Determination of metal content by ICP-OES
  • 15/30315346 DC BS ISO 17880. Cellular plastic. Self-supporting metal-faced sandwich panels. Complementary element
  • BS EN 24883:1993 Specification for hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Solution method
  • PD CEN/TS 17774:2022 Organic and organo-mineral fertilizers. Determination of the content of specific elements by ICP-AES after extraction by water
  • PD ISO/TS 16965:2013 Soil quality. Determination of trace elements using inductively coupled plasma mass spectrometry (ICP-MS)
  • BS ISO 5724:2023 Jewellery and precious metals. Determination of very high purity gold. Difference method using ICP-MS
  • BS EN ISO 11885:2009 Water quality. Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
  • BS ISO 17294-2:2003 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Determination of 62 elements
  • BS EN ISO 17294-2:2003 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Determination of 62 elements
  • PD CEN/TS 17770:2022 Organic and organo-mineral fertilizers. Determination of the total content of specific elements by ICP-AES after digestion by aqua regia
  • BS ISO 19050:2021 Tracked Changes. Rubber, raw, vulcanized. Determination of metal content by ICP-OES
  • 23/30433810 DC BS ISO 5724. Jewellery and precious metals. Determination of very high purity gold. Difference method using ICP-MS
  • BS EN 17264:2019 Foodstuffs. Determination of elements and their chemical species. Determination of aluminium by inductively coupled plasma mass spectrometry (ICP-MS)
  • BS ISO 11494:2008 Jewellery - Determination of platinum in platinum jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element
  • BS ISO 11495:2008 Jewellery - Determination of palladium in palladium jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element
  • BS ISO 15836-2:2019 Information and documentation. The Dublin Core metadata element set - DCMI Properties and classes
  • BS EN 15111:2007 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)
  • BS ISO 21033:2016 Animal and vegetable fats and oils. Determination of trace elements by inductively coupled plasma optical emission spectroscopy (ICP-OES)
  • BS EN ISO 17294-2:2016 Tracked Changes. Water quality. Application of inductively coupled plasma mass spectrometry (ICP-MS). Determination of selected elements including uranium isotopes
  • 19/30375712 DC BS ISO 15093. Jewellery and precious metals. Determination of 999 <sup>0<sup>/<sub>00<sub> gold, platinum and palladium. Difference method using ICP-OES
  • BS EN 17265:2019 Foodstuffs. Determination of elements and their chemical species. Determination of aluminium by inductively coupled plasma optical emission spectometry (ICP-OES)
  • DD CEN/TS 15111:2005 Foodstuffs. Determination of trace elements. Determination of iodine in dietetic foods by ICP-MS (inductively coupled plasma mass spectrometry)
  • BS EN 62321-4:2014 Determination of certain substances in electrotechnical products. Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS
  • BS DD CEN/TS 15111:2005 Foodstuffs - Determination of trace elements - Determination of iodine in dietetic foods by ICP-MS (inductively coupled plasma mass spectrometry)
  • BS ISO 24047:2021 Plastics. Polyethylene (PE) and polypropylene (PP) thermoplastics. Determination of metal content by ICP-OES

Professional Standard - Electron, icp metal element

  • SJ/T 10626-1995 Method for determining impurities in gold wire for semiconductor lead bonding by ICP-AES

European Committee for Standardization (CEN), icp metal element

  • EN 17053:2018 Animal feeding stuffs: Methods of sampling and analysis - Determination of trace elements@ heavy metals and other elements in feed by ICP-MS (multi-method)
  • EN ISO 11494:2016 Jewellery - Determination of platinum in platinum jewellery alloys - ICP-OES method using yttrium as internal standard element (ISO 11494:2014)
  • EN ISO 11494:2019 Jewellery and precious metals - Determination of platinum in platinum alloys - ICP-OES method using an internal standard element (ISO 11494:2019)
  • EN ISO 11885:2009 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
  • EN 24503:1993 Hardmetals; determination of contents of metallic elements by X-ray fluorescence; fusion method (ISO 4503:1978)
  • EN 24883:1993 Hardmetals; determination of contents of metallic elements by X-ray fluorescence; solution method (ISO 4883:1978)
  • FprCEN/TS 17774-2021 Organic and organo-mineral fertilizers - Determination of the content of specific elements by ICP-AES after extraction by water
  • EN 16801:2016 Foodstuffs - Determination of elements and their chemical species - Determination of methylmercury in foodstuffs of marine origin by isotope dilution GC-ICP-MS
  • FprCEN/TS 17770-2021 Organic and organo-mineral fertilizers - Determination of the total content of specific elements by ICP-AES after digestion by aqua regia
  • EN 15111:2007 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)
  • EN ISO 17294-2:2016 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
  • PD CEN/TS 16317:2012 Fertilizers - Determination of trace elements - Determination of arsenic by inductively coupled plasma-atomic emission spectrometry (ICP-AES) after aqua regia dissolution

BELST, icp metal element

Japanese Industrial Standards Committee (JISC), icp metal element

  • JIS G 1323-7:2017 Method for chemical analysis of chromium metal -- Part 7: Determination of various elements -- ICP atomic emission spectrometric method
  • JIS K 0553:1995 Testing methods for determination of metallic elements in highly purified water
  • JIS K 0553:2002 Testing methods for determination of metallic elements in highly purified water
  • JIS K 0553 ERRATUM 1:2002 Testing methods for determination of metallic elements in highly purified water (Erratum 1)

American Society for Testing and Materials (ASTM), icp metal element

  • ASTM UOP961-12 Elemental Composition of Zeolites by ICP-OES
  • ASTM UOP961-98 Elemental Composition of Zeolites by ICP-AES
  • ASTM UOP714-07 Metals in Miscellaneous Samples by ICP-OES
  • ASTM UOP1005-14 Trace Metals in Organics by ICP-MS
  • ASTM UOP714-87 Metals in Miscellaneous Samples by ICP-AES
  • ASTM UOP1003-13 Trace Metals in Methanol by ICP-OES
  • ASTM D5185-05 Standard Test Method for Determination of Additive Elements, Wear Metals, and Contaminants in Used Lubricating Oils and Determination of Selected Elements in Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)
  • ASTM UOP389-15 Trace Metals in Organics by ICP-OES
  • ASTM UOP389-14 Trace Metals in Organics by ICP-OES
  • ASTM UOP389-04 Trace Metals in Oils by Wet Ashing and ICP-OES
  • ASTM UOP389-10 Trace Metals in Organics by Wet Ashing - ICP-OES
  • ASTM UOP873-86 Noble Metals and Modifiers in Catalysts by ICP-AES
  • ASTM UOP927-92 Trace Metallic Impurities in Fresh Catalysts by ICP-AES
  • ASTM UOP389-09 Trace Metals in Organics by Wet Ashing - ICP-OES
  • ASTM UOP389-09a Trace Metals in Organics by Wet Ashing - ICP-OES
  • ASTM C1301-95(2001) Standard Test Method for Major and Trace Elements in Limestone and Lime by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP) and Atomic Absorption (AA)
  • ASTM C1301-95(2014) Standard Test Method for Major and Trace Elements in Limestone and Lime by Inductively Coupled Plasma-Atomic Emission Spectroscopy 40;ICP41; and Atomic Absorption 40;AA41;
  • ASTM D7151-05 Standard Test Method for Determination of Elements in Insulating Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)
  • ASTM D8469-22 Standard Test Method for Analysis of Multiple Elements in Cannabis Matrices by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
  • ASTM D4951-14 Standard Test Method for Determination of Additive Elements in Lubricating Oils by Inductively Coupled Plasma Atomic Emission Spectrometry
  • ASTM D846-84 Standard Test Method for Analysis of Multiple Elements in Cannabis Matrices by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
  • ASTM E2330-04 Standard Test Method for Determination of Trace Elements in Glass Samples Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Universal Oil Products Company (UOP), icp metal element

Taiwan Provincial Standard of the People's Republic of China, icp metal element

  • CNS 14640-2002 Methods of test for metallic elements in highly purified water
  • CNS 12996-1992 Method of Determination for Contents of Metallic Elements of Hardmetals by X-Ray Fluorescence (Fusion Method)
  • CNS 13056-1992 Methods of Determination for Rare Earths in Magnesium Alloys

Professional Standard - Nuclear Industry, icp metal element

  • EJ/T 1220-2007 Determination of metallic impurities in natural uranium hexafluoride by ICP-AES
  • EJ/T 1102-1999 Determination of silver i.e 24 trace elements in natural uranium dioxide by ICP-AES
  • EJ/T 20147-2016 Determination of 13 impurity elements such as magnesium in cobalt powder and sintered cobalt pellets by ICP-AES method
  • EJ/T 1212.4-2008 Test methods for analysis of sintered gadolinium oxide-uranium dioxide pellets.Part4: Determination of trace impurity ICP-AES multi-spectral-fitting method

General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China, icp metal element

  • GB/T 13748.20-2009 Chemical analysis methods of magnesium and magnesium alloys.Part 20:Determination of elements by inductively coupled plasma atomic emission spectrometry
  • GB/T 21198.2-2007 Determination of precious metals in precious metals j ewellery alloys.Method using ICP spectrometry.Part 2:Platinum jewellery alloys--Determination of platinum.Method using the intensity ratios of all minor constituents with reference to platinum
  • GB 20814-2014 Limit and determination of the quantity of heavy-metal elements in dye products
  • GB/T 26050-2010 Hardmetals.Determination of contents of metallic elements by X-ray fluorescence.Fusion method
  • GB 20424-2006 The specification for limit on harmful element content of the heavy metal concentrates products
  • GB/T 13372-1992 Determination of trace elements in uranium dioxide powders and pellets by ICP-AES
  • GB 20814-2006 Limit and determination of the quantity of 10 heavy-metal elements in dye products
  • GB/T 21198.6-2007 Determination of precious metals in precious metals jewellery alloys-Method using ICP spectrometry-Part 6:Difference method
  • GB/T 25934.3-2010 Methods for chemical analysis of high purity gold.Part 3:Ethylether extraction separation-inductively coupled plasma-atomic emission spectrometry.Determination of impurity elements contents
  • GB/T 21198.4-2007 Determination of precious metals in precious metals jewellery alloys.Method using ICP spectrometry.Part 4: 999‰ precious metals jewellery alloys.Determination of precious metals.Difference method
  • GB/T 25934.1-2010 Methods for chemical analysis of high purity gold.Part 1: Ethyl acetate extraction separation-inductively coupled plasma-atomic emission spectrometry.Determination of impurity elements contents
  • GB/T 25934.2-2010 Methods for chemical analysis of high purity gold.Part 2: Inductively coupled plasma mass spectrometry standard enter emendation-inner standard method.Determination of impurity elements contents
  • GB/T 33042-2016 Determination of lead, cadmium, chromium, mercury in the surface decorated layer of wooden floor
  • GB/T 21834-2008 Medium and low alloy steel-Determination of the distribution of multi-element contents-Original position statistic distribution analysis method
  • GB/T 6887-2007 Sintered metal filter elements
  • GB/T 30903-2014 Inorganic chemicals for industrial use.Determination of impurity element.Inductively coupled plasma mass spectrometry(ICP-MS)
  • GB/T 30570-2014 Structural main factors of sheet metal stamping parts
  • GB/T 30902-2014 Inorganic chemicals for industrial use.Determination of impurity element.Inductively coupled plasma optical emission spectrometry (ICP-OES)
  • GB/T 21198.5-2007 Determination of precious metals in precious metals jewellery alloys.Method using ICP spectrometry.Part 5: 999‰silver jewellery alloys.Determination of silver.Difference method
  • GB/T 21198.1-2007 Determination of precious metals in precious metals jewellery alloys- Method using ICP spectrometry- Part 1: Platinum jewellery alloys- Determination of platinum-Method using a solution with yttrium as internal standard element
  • GB/T 21198.3-2007 Determination of precious metals in precious metals jewellery alloys.Method using ICP spectrometry.Part 3: Palladium jewellery alloys.Determination of palladium.Method using a solution with yttrium as internal standard element
  • GB/T 24271-2009 Specification for strip component of thermostat metals
  • GB/T 19900-2005 Dimensions of metal-sheathed thermometer elements
  • GB/T 17476-1998 Standard test method for determination of additive elements, wear metals, and contaminants in used lubricanting oils and determination of selected elements in base oils by inductively coupled plasma atomic emission spectrometry (ICP-AES)
  • GB/T 37211.3-2022 Method for chemical analysis of metal germanium—Part 3: Determination of trace impurity elements content—Glow discharge mass spectrometry

Korean Agency for Technology and Standards (KATS), icp metal element

  • KS I 3203-2007(2012) Testing methods for determination of metallic elements in highly purified water
  • KS M 0073-1997
  • KS I 3203-2021 Testing methods for determination of metallic elements in highly purified water
  • KS I 3203-2007 Testing methods for determination of metallic elements in highly purified water
  • KS D ISO 4883-2003(2018) Hardmetals-Determination of contents of metallic elements by X-ray fluorescence-Solution method
  • KS D ISO 4503-2003(2018) Hardmetals-Determination of contents of metallic elements by X-ray fluorescence-Fusion method
  • KS C IEC 61167:2002 Metal halide Lamps
  • KS C IEC 61167:2014 Metal halide lamps
  • KS D ISO 4503:2003 Hardmetals-Determination of contents of metallic elements by X-ray fluorescence-Fusion method
  • KS D ISO 4883:2003 Hardmetals-Determination of contents of metallic elements by X-ray fluorescence-Solution method
  • KS M 1064-2005 Determination of lead(Pb) and cadmium(Cd) in metals byICP-AES/MS and AAS
  • KS I ISO 11885-2008(2018) Water quality-Determination of selected elements by inductively coupled plasma optical emission spectrometry(ICP-OES)
  • KS I ISO 11885:2008 Water quality-Determination of selected elements by inductively coupled plasma optical emission spectrometry(ICP-OES)
  • KS X 1517-3-2006 INFORMATION TECHNOLOGY- SPECIFICATION AND STANDARDIZATION OF DATA ELEMENTS- PART 3: BASIC ATTRIBUTES OF DATA ELEMENTS
  • KS X 1517-3-2003 INFORMATION TECHNOLOGY- SPECIFICATION AND STANDARDIZATION OF DATA ELEMENTS- PART 3: BASIC ATTRIBUTES OF DATA ELEMENTS
  • KS D 2042-1997(2003) METHODS FOR DETERMINATION OF RARE EARTHS IN MAGNESIUM ALLOYS
  • KS D ISO 3110:2002 Copper alloys-Determination of aluminium as alloying element-Volumetric method
  • KS D ISO 3111:2002 Copper alloys-Determination of tin as alloying element-Volumetric method
  • KS I ISO 17294-2:2010 Water quality-Application of inductively coupled plasma mass spectrometry(ICP-MS)-Part 2:Determination of 62 elements
  • KS C IEC 61152:2004 Dimensions of metal-sheathed thermometer elements
  • KS C IEC 61152:2013 Dimensions of metal-sheathed thermometer elements
  • KS C IEC 62321-4-2014(2019) Determination of certain substances in electrotechnical products — Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS
  • KS C IEC 61152-2004(2009) Dimensions of metal-sheathed thermometer elements
  • KS M 2618-2013 Determination of additive elements, wear metals, contaminants and selected elements in used lubricating oils and base oils-Inductively coupled plasma atomic emission spectrometry
  • KS D 1938-2003(2013) Determination of element content in zinc and zinc alloy

Professional Standard - Electricity, icp metal element

  • DL/T 263-2012 Analytical the progress methods of metal elements in transformer oil
  • DL/T 263-2021 Determination method of metal elements in transformer oil

AENOR, icp metal element

  • UNE-EN ISO 11494:2017 Jewellery - Determination of platinum in platinum jewellery alloys - ICP-OES method using yttrium as internal standard element (ISO 11494:2014)
  • UNE 135122:2012 Metallic safety barriers for vehicles restraint. Accessory elements of the metallic barriers. Materials, geometry, dimensions and tests.
  • UNE-EN 15111:2007 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)
  • UNE-EN ISO 11885:2010 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (ISO 11885:2007)
  • UNE 36317-2:1989 Chemical analysis of ferrous materials - Determination of nitrogen (trace mounts) in steel - Spectrophotometric method
  • UNE-EN 15765:2010 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion
  • UNE 38860:2003 Magnesium and magnesium alloys. Determination of rare earths. Gravimetric method.
  • UNE-EN 12149:1998 WALLCOVERINGS IN ROLL FORM. DETERMINATION OF MIGRATION OF HEAVY METALS AND CERTAIN OTHER ELEMENTS, OF VINYL CHLORIDE MONOMER AND OF FORMALDEHYDE RELEASE.

工业和信息化部, icp metal element

  • HG/T 5765-2020 Determination of metal elements in catalytic cracking catalysts
  • HG/T 5763-2020 Determination of metal elements in metallocene polyolefin catalysts by inductively coupled plasma optical emission spectrometry
  • SJ/T 11555-2015 Determination of metal element content in nitric acid using inductively coupled plasma mass spectrometry
  • JB/T 13636-2020 Technical conditions of thermal bimetallic component alloys
  • SJ/T 11554-2015 Determination of metal element content in hydrofluoric acid using inductively coupled plasma optical emission spectrometry
  • XB/T 628-2020 Chemical Analysis Methods for High Purity Rare Earth Metals Determination of Trace Element Content Glow Discharge Mass Spectrometry

Professional Standard - Commodity Inspection, icp metal element

  • SN/T 3619-2013 Determination of 17 migration elements in toy materials.Inductively coupled plasma mass spectrometer
  • SN/T 2081-2008 Determination of impurities in alumina.Inductively coupled plasma atomic emission spectrometric method (ICP-AES) with microwave dissolution

Group Standards of the People's Republic of China, icp metal element

  • T/CSEA 12-2019 Boron Sulfur Phosphorus Chlorine Additives-Free Metal Working Fluid
  • T/CCAS 019-2021 Determination of heavy metals in cement and clinker-ICP-OES method
  • T/ZZB 2577-2021 Thermostat component alloys strip
  • T/NAIA 0157-2022 Determination of Titanium in Carburizer by Inductively Coupled Plasma Emission Spectrometry (ICP-AES)
  • T/GDPIA 37-2021 Determination of mobile elements in post-consumer plastics Inductively coupled plasma mass spectrometry method (ICP-MS)
  • T/HEEPA 7-2023 Technical specifications for on-site monitoring of soil heavy metal elements by laser-induced breakdown spectroscopy
  • T/BASE 1.2-2022 The Dublin Core metadata element set Part 2:DCMI Properties and classe
  • T/CEEIA 298-2018 Corrosion resistant metallic tube electric heating elements
  • T/CASAS 032-2023 Test method for the content of metal elements on the surface of silicon carbide wafer—Inductively coupled plasma mass spectrometry
  • T/CGIA 012-2019 Determination of metallic elements in graphene materials — Inductively coupled plasma emission spectrometry
  • T/CATCM 001-2018 Pollution-free ginseng radix et rhizome and decoction pieces— Limit of the pesticide residue, heavy metal contents and harmful elements
  • T/CATCM 009-2019 Maximum Residue Limits of Heavy Metals and Harmful Elements in Cordyceps Sinensis Medicinal Materials and Decoction Pieces for Pollution-free Breeding

Professional Standard - Petroleum, icp metal element

  • SY 5161-2002 Atomic absorption spectrometry method for determination of metal elements in rocks
  • SY/T 5161-2002 Determination of some metal elements in rocks by atomic absorption spectrometry
  • SY 5982-1994 Determination of metal elements in oil and gas field water by atomic absorption spectrometry
  • SY/T 5982-1994 Determination of metal elements in oil and gas field water by atomic absorption spectrometry
  • SY/T 6404-1999 Analytical method of metal elements in sediment rock by ICP-AES

BE-NBN, icp metal element

  • NBN-EN 24503-1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Fusion method (ISO 4503:1978)
  • NBN-EN 24883-1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Solution method (ISO 4883: 1978)

RU-GOST R, icp metal element

  • GOST 25702.10-1983 Raremetallic concentrates. Method for the determination of sum of rare earths
  • GOST R 56219-2014 Water. Determination of 62 elements by inductively coupled plasma mass spectrometry (ICP-MS) method
  • GOST R 51056-1997 Alloyed and high-alloyed steel. Atomic emission spectrometry method of determination of tungsten and molibdenum
  • GOST EN 15111-2015 Foodstuffs. Determination of trace elements. Determination of iodine by ISP-MS (inductively coupled plasma mass spectrometry)
  • GOST 23862.1-1979 Rare-earth metals and their oxides. Spectral method of determination of impurities in oxides of rare-earth elements
  • GOST 23862.2-1979 Rare-earth metals and their oxides. Direct spectral method of determination of impurities in oxides of rare-earth elements
  • GOST 473.4-1981 Vanadium base alloys and alloying elements. Methods for determination of silicon
  • GOST 23862.7-1979 Rare-earth metals and their oxides. Chemical-spectral methods of determination of impurities in oxides of rare-earth elements
  • GOST 3240.16-1976 Magnesium alloys. Methods for determination of sum of rare-earth elements and cerium

中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会, icp metal element

  • GB/T 20424-2006 The specification for limit on harmful element content of the heavy metal concentrates products
  • GB/T 34504-2017 Measurement method for surface metal contamination on sapphire polished substrate wafer
  • GB/T 34646-2017 Sintered metal membrane filter materials and elements

国家市场监督管理总局、中国国家标准化管理委员会, icp metal element

  • GB/T 40114-2021 Jewellery—Determination of precious metal content—Difference method using inductively coupled plasma optical emission spectroscopy
  • GB/T 38145-2019 High content precious metals jewellery alloys—Determination of gold,platinum and palladium—Difference method using inductively coupled plasma optical emission spectroscopy
  • GB/T 40493-2021 Determination of lead, cadmium, chromium and mercury content in the finishing material of wood-based panel
  • GB/T 39994-2021 Determination of six metal elements (iron, calcium, magnesium, zinc, titanium,copper) in polyolefin pipe system
  • GB/T 6887-2019 Sintered metal filter elements
  • GB/T 39145-2020 Test method for the content of surface metal elements on silicon wafers—Inductively coupled plasma mass spectrometry
  • GB/T 37248-2018 High purity aluminium oxide—Determination of trace metal elements—Inductively coupled plasma optical emission spectrometry
  • GB/T 39560.4-2021 Determination of certain substances in electrical and electronic products—Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS , ICP-OES and ICP-MS

Professional Standard - Chemical Industry, icp metal element

  • HG/T 3942-2007 Sodium hydroxide for industrial use.Determination of metal and nonmetal ions content.ICP method
  • HG/T 3944-2007 Poly (vinyl chloride) resin.Determination of metal ions content.ICP method
  • HG/T 5018-2016 Determination methods of the major components and trace metal elements in waste etching liquor containing copper
  • HG/T 3941-2007;HG/T 3942-2007 Determination of Moisture Content in Industrial Liquid Chlorine Coulometric Method Determination of Metal and Non-metal Ion Content in Industrial Sodium Hydroxide

Danish Standards Foundation, icp metal element

  • DS/EN 24883:1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Solution method
  • DS/EN 24503:1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Fusion method
  • DS/EN 24503:1994 Hardmetals - Determination of contents of metallic elements by X-ray fluorescence - Fusion method
  • DS/ISO 4503:1994 Hardmetals - Determination of contents of metallic elements by X-ray fluorescence - Fusion method
  • DS/EN 24883:1994 Hardmetals - Determination of contents of metallic elements by x-ray fluorescence - Solution method
  • DS/ISO 4883:1994 Hardmetals - Determination of contents of metallic elements by x-ray fluorescence - Solution method
  • DS/ISO 11494:2008 Jewellery - Determination of platinum in platinum jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element
  • DS/ISO 11495:2008 Jewellery - Determination of palladium in palladium jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element
  • DS/ISO/TS 16965:2013 Soil quality - Determination of trace elements using inductively coupled plasma mass spectrometry (ICP-MS)
  • DS/EN ISO 11885:2009 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
  • DS/EN 15111:2007 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)
  • DS/EN 12938/AC:2001 Methods for the analysis of pewter - Determination of alloying and impurity element contents by atomic spectrometry
  • DS/EN 12938:2001 Methods for the analysis of pewter - Determination of alloying and impurity element contents by atomic spectrometry
  • DS/EN ISO 17294-2:2005 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of 62 elements
  • DS/EN 15765:2010 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion
  • DS/EN 61152:2012 Dimensions of metal-sheathed thermometer elements
  • DS/ISO 21392:2021 Cosmetics – Analytical methods – Measurement of traces of heavy metals in cosmetic finished products using ICP/MS technique
  • DS/CEN/TS 16171:2013 Sludge, treated biowaste and soil - Determination of elements using inductively coupled plasma mass spectrometry (ICP-MS)

KR-KS, icp metal element

  • KS D ISO 4883-2003(2023) Hardmetals-Determination of contents of metallic elements by X-ray fluorescence-Solution method
  • KS D ISO 4503-2003(2023) Hardmetals-Determination of contents of metallic elements by X-ray fluorescence-Fusion method
  • KS I ISO 17294-2-2010 Water quality-Application of inductively coupled plasma mass spectrometry(ICP-MS)-Part 2:Determination of 62 elements

Shaanxi Provincial Standard of the People's Republic of China, icp metal element

  • DB61/T 902.1-2013 Determination of heavy metal elements in plant extracts Determination of cadmium
  • DB61/T 902.3-2013 Determination of heavy metal elements in plant extracts Determination of lead
  • DB61/T 902.4-2013 Determination of heavy metal elements in plant extracts Determination of copper
  • DB61/T 902.2-2013 Determination of heavy metal elements in plant extracts Determination of chromium
  • DB61/T 902.6-2013 Determination of heavy metal elements in plant extracts Determination of total mercury
  • DB61/T 902.5-2013 Determination of heavy metal elements in plant extracts Determination of total arsenic
  • DB61/T 1162-2018 Determination of Heavy Metal Elements in Soil by Energy Dispersive X-ray Fluorescence Spectrometry

Professional Standard - Non-ferrous Metal, icp metal element

  • YS/T 372.7-2006 Methods for elementary analysis of precious alloy. Determination of cobalt content. EDTA complexometric titration
  • YS/T 372.9-2006 Methods for elementary analysis of precious alloy. Determination of nickel content.EDTA complexometric titration
  • YS/T 372.11-2006 Methods for elementary analysis of precious alloy.Determination of magnesium content.EDTA complexometric titration
  • YS/T 372.12-2006 Methods for elementary analysis of precious alloy.Determination of zinc content.EDTA complexometric titration
  • YS/T 372.13-2006 Methods for elementary analysis of precious alloy. Determination of tin content. EDTA complexometric titration
  • YS/T 372.16-2006 Methods for elementary analysis of precious alloy. Determination of gallium content. EDTA complexomeric titration
  • YS/T 372.21-2006 Methods for elementary analysis of precious alloy. Determination of zirconium content. EDTA complexometric titration
  • YS/T 372.22-2006 Methods for elementary analysis of precious alloy. Determination of indium content. EDTA complexometric titration
  • YS/T 372.11-1994 Methods for elementary analysis of precious alloy.Determination of magnesium content.EDTA complexometric titration
  • YS/T 372.12-1994 Methods for elementary analysis of precious alloy.Determination of zinc content.EDTA complexometric titration
  • YS/T 372.13-1994 Methods for elementary analysis of precious alloy. Determination of tin content. EDTA complexometric titration
  • YS/T 372.7-1994 Methods for elementary analysis of precious alloy. Determination of cobalt content. EDTA complexometric titration
  • YS/T 372.5-2006 Methods for elementary analysis of precious alloy. Determination of copper content in PtCu alloy. EDTA complexometric titration
  • YS/T 372.8-2006 Methods for elementary analysis of precious alloy. Determination of cobalt content in PtCo alloy. EDTA complexometric titration
  • YS/T 372.5-1994 Methods for elementary analysis of precious alloy. Determination of copper content in PtCu alloy. EDTA complexometric titration
  • YS/T 372.1-2006 Methods for elementary analysis of precious alloy. Determination of silver content. Potentiometer titration with potassium iodide
  • YS/T 372.1-1994 Methods for elementary analysis of precious alloy. Determination of silver content. Potentiometer titration with potassium iodide
  • YS/T 372.2-2006 Methods for elementary analysis of precious alloy. Determination of platinum content. Electricity titration using potassium permanganate
  • YS/T 372.15-2006 Methods for elementary analysis of precious alloy. Determination of antimony content. The flame atomic absorption spectrometric method
  • YS/T 372.14-2006 Methods for elementary analysis of precious alloy. Determination of manganese content. Potentiometer titration using potassium permanganate
  • YS/T 372.14-1994 Methods for elementary analysis of precious alloy. Determination of manganese content. Potentiometer titration using potassium permanganate
  • YS/T 372.2-1994 Methods for elementary analysis of precious alloy. Determination of platinum content. Electricity titration using potassium permanganate
  • YS/T 372.10-2006 Methods for elementary analysis of precious alloy. Determination of nickel content in AuNi and PdNi alloy. EDTA complexometric titration
  • YS/T 372.10-1994 Methods for elementary analysis of precious alloy. Determination of nickel content in AuNi and PdNi alloy. EDTA complexometric titration
  • YS/T 372.4-2006 Methods for elementary analysis of precious alloy. Determination of copper content.Complexometric titration using thiourea releasing EDTA
  • YS/T 372.6-2006 Methods for elementary analysis of precious alloy. Determination of copper content and manganese contents. The flame atomic absorption spectrometric method
  • YS/T 372.18-2006 Methods for elementary analysis of precious alloy. Determination of gadolinium content. Chlorophosphonazo Ⅲ spectrophotometry
  • YS/T 372.19-2006 Methods for elementary analysis of precious alloy. Determination of yttrium content.Chlorophosphonazo Ⅲ spectrophotometry
  • YS/T 372.4-1994 Methods for elementary analysis of precious alloy. Determination of copper content.Complexometric titration using thiourea releasing EDTA
  • YS/T 372.6-1994 Methods for elementary analysis of precious alloy. Determination of copper content and manganese contents. The flame atomic absorption spectrometric method
  • YS/T 372.3-2006 Methods for elementary analysis of precious alloy. Determination of palladoum content. Complexometric titration using butanedione dioxime releasing EDTA
  • YS/T 372.20-2006 Methods for elementary analysis of precious alloy. Determination of cadmium content. Complexometric titration using potassium iodide releasing EDTA
  • YS/T 372.3-1994 Methods for elementary analysis of precious alloy. Determination of palladoum content. Complexometric titration using butanedione dioxime releasing EDTA
  • YS/T 372.17-2006 Methods for elementary analysis of precious alloy. Determination of tungsten and rhenium content. Tungstic acid gravimetry and thiourea spectrophotometry

PL-PKN, icp metal element

Professional Standard - Environmental Protection, icp metal element

  • HJ 832-2017 Determination of Total Metal Elements in Soil and Sediment Microwave Digestion Method
  • HJ 766-2015 Solid Waste–Determination of metals–Inductively coupled plasma mass spectrometry (ICP-MS)
  • HJ 781-2016 Solid waste – Determination of 22 metal elements – Inductively coupled plasma optical emission spectrometry
  • HJ 657-2013 Ambient air and stationary source emission.Determination of metals in ambient particulate matter.Inductively coupled plasma/mass spectrometry (ICP-MS)
  • HJ 777-2015 Ambient air and waste gas from stationary sources emission -Determination of metal elements in ambient particle matter-Inductively coupled plasma optical emission spectrometry

YU-JUS, icp metal element

  • JUS C.N2.004-1988 Powder metallurgy. Sintered metal materials. Sintered iron and sintered steel containing one or both of the elements carbon and copper, used for structural parts. Specifications

IT-UNI, icp metal element

  • UNI 7850-1978
  • UNI 3667-1968 Corrosion of metallic materials. Corrosion conditions and factors for metallic materials in conctat with solutions.

Defense Logistics Agency, icp metal element

  • DLA QPL-49465-16-2006 RESISTORS, FIXED, METAL ELEMENT (POWER TYPE), VERY LOW RESISTANCE VALUES, GENERAL SPECIFICATION FOR

RO-ASRO, icp metal element

  • STAS 8640/1-1970 Files for non-ferrons metale working DESIGN ELEMENTS AND CEOMETRICAL PARAMETERS OF TOOTH
  • STAS 4605/15-1972 NON-METAL BEARING MINING PRODUCTS WITH CARBONATE CONTENT Spectral analysis of Fe, Ti, Ca, Mg, Mn, Cu elements
  • STAS 8894/1-1980 Testing metals CREEP STRESS RUPTURE TESTING OF STEEL AT ELEVATED TEMPERATURES Elements and technical requirements for testing

AT-ON, icp metal element

  • ONORM M 6279-1991 Water analysis — Determination oj 33 elements by inductively coupled plasma emission spectrometry (ICP-AES)

NL-NEN, icp metal element

  • NEN-ISO 4503:1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Fusion method (ISO 4503:1978)
  • NEN-ISO 4883:1993 Hardmetals. Determination of contents of metallic elements by X-ray fluorescence. Solution method (ISO 4883:1978)

Professional Standard - Medicine, icp metal element

  • YY/T 1507.4-2016 Determination the content of impurity element in the implant for surgery ultra-high molecular weight polyethylene powder.Part 4:Determination of aluminum by ICP-MS

国家食品药品监督管理局, icp metal element

  • YY/T 1507.3-2016 Determination of impurity elements in ultra-high molecular weight polyethylene powder for surgical implants Part 3 Determination of calcium (Ca) element content by ICP-MS
  • YY/T 1507.1-2016 Determination of impurity elements in ultra-high molecular weight polyethylene powder for surgical implants Part 1 Determination of titanium (Ti) element content by ICP-MS

Lithuanian Standards Office , icp metal element

  • LST EN 24883-2001 Hardmetals - Determination of contents of metallic elements by X-ray fluorescence - Solution method (ISO 4883:1978)
  • LST EN 24503-2001 Hardmetals - Determination of contents of metallic elements by X-ray fluorescence - Fusion method (ISO 4503:1978)
  • LST ISO 11494:2009 Jewellery - Determination of platinum in platinum jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element (ISO 11494:2008, identical)
  • LST ISO 11495:2009 Jewellery - Determination of palladium in palladium jewellery alloys - Inductively coupled plasma (ICP) solution-spectrometric method using yttrium as internal standard element (ISO 11495:2008, identical)
  • LST EN 15111-2007 Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)
  • LST EN 12938-2000 Methods for the analysis of pewter - Determination of alloying and impurity element contents by atomic spectrometry
  • LST EN 12938-2000/AC-2003 Methods for the analysis of pewter - Determination of alloying and impurity element contents by atomic spectrometry
  • LST EN ISO 11885:2009 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (ISO 11885:2007)
  • LST EN 10179-2000 Chemical analysis of ferrous materials - Determination of nitrogen (trace mounts) in steel - Spectrophotometric method
  • LST EN 15765-2010 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion

VN-TCVN, icp metal element

  • TCVN 6665-2011 Water quality.Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
  • TCVN 5919-1995 Copper alloys.Determination of aluminium as alloying element.Volumetric method

Professional Standard - Water Conservancy, icp metal element

  • SL 394.2-2007 Determination of 34 elements(Pb,Cd,V,P etc.).Inductively coupled plasma mass spectroscopy (ICP-MS)
  • SL 394.1-2007 Determination of 34 elements(Pb,Cd,V,P etc.).Inductively coupled plasma atomic emission spectroscopy (ICP-AES)

Xinjiang Provincial Standard of the People's Republic of China, icp metal element

  • DB65/T 3974-2017 Determination of Heavy Metal Elements in Soil by Inductively Coupled Plasma Mass Spectrometry
  • DB65/T 3971-2017 Simultaneous Determination of Multiple Heavy Metals in Vegetables and Fruits by Plasma Mass Spectrometry

Professional Standard - Machinery, icp metal element

住房和城乡建设部, icp metal element

ZA-SANS, icp metal element

  • SANS 11885:2008 Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)

Society of Automotive Engineers (SAE), icp metal element

SAE - SAE International, icp metal element

未注明发布机构, icp metal element

  • SAE AMS2280D-2019 Trace Element Control Nickel Alloy Castings
  • BS EN 16171:2016 Sludge, treated biowaste and soil — Determination of elements using inductively coupled plasma mass spectrometry (ICP - MS)

Professional Standard - Energy, icp metal element

  • NB/SH/T 0864-2013 Standard test method for determination of metals in lubricating greases by inductively coupled plasma atomic emission spectrometry

Professional Standard - Building Materials, icp metal element

  • JC/T 2147-2012 Determination of trace metal elements in high purity alumina by inductively coupled plasma atomic emission spectrometry

American National Standards Institute (ANSI), icp metal element

United States Navy, icp metal element

  • NAVY MIL-STD-276 A-1992 IMPREGNATION OF POROUS METAL CASTINGS AND POWDERED METAL COMPONENTS [Superseded: ARMY MIL-I-7878 (1), ARMY MIL-I-7878, NAVY MIL-I-17414 CANC NOTICE 1, NAVY MIL-I-17414]

Tianjin Provincial Standard of the People's Republic of China, icp metal element

  • DB12/T 1020-2020 Determination method of heavy metal elements in seafood by inductively coupled plasma mass spectrometry

国家能源局, icp metal element

  • NB/SH/T 0934-2016 Standard test method for determination of trace elements in petroleum coke by wavelength dispersive X-ray fluorescence Spectroscopy
  • SH/T 0934-2016 Determination of trace metal elements in petroleum coke by wavelength dispersive X-ray fluorescence spectrometry
  • NB/T 10309-2019 Anti-corrosion metal tubular electric heating element
  • SY/T 6404-2018 Inductively coupled plasma atomic emission spectrometry and mass spectrometry analysis methods of metal elements in rocks

SK-STN, icp metal element

  • STN EN ISO 11885:2009 Water quality.Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (ISO 11885:2007)

Standard Association of Australia (SAA), icp metal element

Qinghai Provincial Standard of the People's Republic of China, icp metal element

  • DB63/T 1871-2020 Determination of Seven Metal Elements in Forage Grass by Microwave Digestion/Inductively Coupled Plasma Mass Spectrometry

American Welding Society (AWS), icp metal element

  • WRC 231:1977 Factors Affecting Weld Metal Properties in Carbon and Low Alloy Pressure Vessel Steels

CEN - European Committee for Standardization, icp metal element

  • EN 15765:2009 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion
  • PD CEN/TS 15111:2005 Foodstuffs Determination of trace elements Determination of iodine in dietetic foods by ICP-MS (inductively coupled plasma mass spectrometry)

Professional Standard - Ferrous Metallurgy, icp metal element

CZ-CSN, icp metal element

WRC - Welding Research Council, icp metal element

CENELEC - European Committee for Electrotechnical Standardization, icp metal element

  • EN 50288-1:2001 Multi-Element Metallic Cables Used in Analogue and Digital Communication and Control Part 1: Generic Specification

Shandong Provincial Standard of the People's Republic of China, icp metal element

  • DB37/T 4435-2021 Determination of Total 14 Metal Elements in Soil and Sediment by Inductively Coupled Plasma Mass Spectrometry
  • DB37/T 4493-2022 Determination of major heavy metal elements in marine sediments by inductively coupled plasma emission spectrometry
  • DB37/T 4494-2022 Determination of major heavy metal elements in marine organisms by inductively coupled plasma emission spectrometry

廊坊市市场监督管理局, icp metal element

  • DB1310/T 229-2020 Determination of metal element content in high-purity carbon materials by inductively coupled plasma optical emission spectrometry

European Committee for Electrotechnical Standardization(CENELEC), icp metal element

International Electrotechnical Commission (IEC), icp metal element

  • IEC 61152:1992 Dimensions of metal-sheathed thermometer elements
  • IEC 62321-4:2013 Determination of certain substances in electrotechnical products - Part 4: Determination of mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP- OES and ICP-MS
  • IEC 62321-4:2013+AMD1:2017 CSV Determination of certain substances in electrotechnical products - Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS
  • IEC 62321-4:2017 Determination of certain substances in electrotechnical products - Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS

机械电子工业部, icp metal element

  • JB 5802-1991 Technical conditions for thermal bimetal strip elements

国家质量监督检验检疫总局, icp metal element

  • SN/T 4513-2016 Simultaneous determination of dissolution amounts of 12 elements in stainless steel containers using inductively coupled plasma mass spectrometry (ICP-MS)

Canadian Standards Association (CSA), icp metal element

  • CSA ISO/IEC-11179-3-00:2000 Information Technology - Specification and Standardization of Data Elements - Part 3: Basic Attributes of Data Elements ISO/IEC 11179-3: 1994
  • CSA ISO/CEI 11179-3-00:2002 Technologies De L碔nformation - Specifications Et Normalisation Des Elements De Donnees - Partie 3: Attributs De Base Des Elements De Donnees Premier Edition; ISO/CEI 11179-3:1994

Guizhou Provincial Standard of the People's Republic of China, icp metal element

  • DB52/T 1695-2022 Technical requirements and detection methods of heavy metal water quality automatic online monitoring system (ICP-MS method)




Copyright ©2007-2023 ANTPEDIA, All Rights Reserved