How to calibrate the spectrometer
How to calibrate the spectrometer, Total:80 items.
In the international standard classification, How to calibrate the spectrometer involves: Fibre optic communications, Optics and optical measurements, Special measuring equipment for use in telecommunications, Metrology and measurement in general, Analytical chemistry, Non-destructive testing, Nuclear energy engineering, Lamps and related equipment, Radiation measurements.
European Committee for Standardization (CEN), How to calibrate the spectrometer
- CEN EN 62129-2006 Calibration of optical spectrum analyzers
- CEN EN 62129-2006_ Calibration of optical
spectrum analyzers
- prEN ISO 23547 Measurement of radioactivity - Gamma emitting radionuclides - Reference measurement standard specifications for the calibration of gamma-ray spectrometers (ISO 23547:2022)
Association Francaise de Normalisation, How to calibrate the spectrometer
- NF C93-845:2006 Calibration of optical spectrum analyzers.
- NF C93-846-1*NF EN 62129-1:2016 Calibration of wavelength/optical frequency measurement instruments - Part 1 : optical spectrum analyzers
- NF X21-055:2006 Surface chemical analysis - X-ray photoelectron spectrometers - Calibration of energy scales.
- NF EN 62129-1:2016 Étalonnage des appareils de mesure de longueur d'onde/appareil de mesure de la fréquence optique - Partie 1 : analyseurs de spectre optique
- NF C93-845-2*NF EN 62150-2:2011 Fibre optic active components and devices - Test and measurement procedures - Part 2 : ATM-PON transceivers.
- NF X21-054*NF ISO 17973:2006 Surface chemical analysis - Medium-resolution Auger electron spectrometers - Calibration of energy scales for elemental analysis.
Danish Standards Foundation, How to calibrate the spectrometer
Japanese Industrial Standards Committee (JISC), How to calibrate the spectrometer
- JIS C 6192:2008 Calibration of optical spectrum analyzers
- JIS K 0165:2011 Surface chemical analysis -- Medium-resolution Auger electron spectrometers -- Calibration of energy scales for elemental analysis
- JIS K 0166:2011 Surface chemical analysis -- High-resolution Auger electron spectrometers -- Calibration of energy scales for elemental and chemical-state analysis
National Metrological Technical Specifications of the People's Republic of China, How to calibrate the spectrometer
- JJF 1818-2020 Calibration Specification for Calibration Device of Raman Spectrometers
- JJF 1544-2015 Calibration Specification for Raman Spectrometers
- JJF 1329-2011 Calibration Specification for Instantaneous Spectral Instruments
- JJF 1601-2016 Calibration Specification for Spectrophotometers for Diffuse Reflectance Measurement
- JJF 1603-2016 Calibration Specification for (0.1~2.5) THz Terahertz Spectrometers
- JJF 2024-2023
- JJF 1319-2011 Calibration Specification for Fourier Transform Infrared Spectrometers
- JJF 1929-2021 Calibration Specification for Rotating Disc Electrode Atomic Emission Spectrometers
- JJF 1133-2005 Calibration Specification of Gold Gauge Utilizing X-ray Fluorescence Spectrometry
- JJF 1953-2021 Calibration Specification for Gas Chromatographs with Sulfur Chemiluminescence Detector
International Electrotechnical Commission (IEC), How to calibrate the spectrometer
- IEC 62129:2006 Calibration of optical spectrum analyzers
- IEC 62129-1:2016 Calibration of wavelength/optical frequency measurement instruments - Part 1: Optical spectrum analyzers
- IEC 61239:1993 Nuclear instrumentation; portable gamma radiation meters and spectrometers used for prospecting; definitions, requirements and calibration
- IEC 61452:2021 Nuclear instrumentation - Measurement of activity or emission rate of gamma- ray emitting radionuclides - Calibration and use of germanium-based spectrometers
British Standards Institution (BSI), How to calibrate the spectrometer
- BS EN 62129-1:2016 Calibration of wavelength/optical frequency measurement instruments. Optical spectrum analyzers
- 18/30382086 DC BS EN 61452. Nuclear instrumentation. Measurement of gamma-ray emission rates of radionuclides. Calibration and use of germanium spectrometers
- 20/30412413 DC BS EN IEC 61452. Nuclear instrumentation. Measurement of gamma-ray emission rates of radionuclides. Calibration and use of germanium spectrometers
- BS IEC 61452:2021 Nuclear instrumentation. Measurement of activity or emission rate of gamma-ray emitting radionuclides. Calibration and use of germanium-based spectrometers
- BS ISO 17973:2003 Surface chemical analysis - Medium-resolution Auger electron spectrometers - Calibration of energy scales for elemental analysis
- BS ISO 17974:2002 Surface chemical analysis - High-resolution Auger electron spectrometers - Calibration of energy scales for elemental and chemical-state analysis
Lithuanian Standards Office , How to calibrate the spectrometer
- LST EN 62129-2006 Calibration of optical spectrum analyzers (IEC 62129:2006)
- LST EN 62129-2006/AC-2007 Calibration of optical spectrum analyzers (IEC 62129:2006)
- LST IEC 61239:2008 Nuclear instrumentation - Portable gamma radiation meters and spectrometers used for prospecting - Definitions, requirements and calibration (IEC 61239:1993, identical)
Group Standards of the People's Republic of China, How to calibrate the spectrometer
IEC - International Electrotechnical Commission, How to calibrate the spectrometer
- PAS 62129-2004 Calibration of optical spectrum analyzers (Edition 1.0;: 2006)
American Society for Testing and Materials (ASTM), How to calibrate the spectrometer
- ASTM E1840-96(2022) Standard Guide for Raman Shift Standards for Spectrometer Calibration
- ASTM E2911-23 Standard Guide for Relative Intensity Correction of Raman Spectrometers
- ASTM E2911-13 Standard Guide for Relative Intensity Correction of Raman Spectrometers
- ASTM E1840-96(2002) Standard Guide for Raman Shift Standards for Spectrometer Calibration
- ASTM E3029-15(2023) Standard Practice for Determining Relative Spectral Correction Factors for Emission Signal of Fluorescence Spectrometers
- ASTM G138-96 Standard Test Method for Calibration of a Spectroradiometer Using a Standard Source of Irradiance
- ASTM E3029-15 Standard Practice for Determining Relative Spectral Correction Factors for Emission Signal of Fluorescence Spectrometers
- ASTM E2056-04(2010) Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses, Calibrated Using Surrogate Mixtures
- ASTM E2056-04(2016) Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses, Calibrated Using Surrogate Mixtures
European Committee for Electrotechnical Standardization(CENELEC), How to calibrate the spectrometer
- EN 62129-1:2016 Calibration of wavelength/optical frequency measurement instruments - Part 1: Optical spectrum analyzers
- EN 62129:2006 Calibration of optical spectrum analyzers (Incorporating corrigendum December 2006)
ES-UNE, How to calibrate the spectrometer
- UNE-EN 62129-1:2016 Calibration of wavelength/optical frequency measurement instruments - Part 1: Optical spectrum analyzers (Endorsed by AENOR in July of 2016.)
Fujian Provincial Standard of the People's Republic of China, How to calibrate the spectrometer
- JJF(闽)1085-2018 Calibration Specification for Portable Raman spectrum fast detection instruments
German Institute for Standardization, How to calibrate the spectrometer
- DIN EN 62129 Berichtigung 1:2008 Calibration of optical spectrum analyzers (IEC 62129:2006); German version EN 62129:2006, Corrigendum to DIN EN 62129:2007-01; German version CENELEC-Cor. :2006 to EN 62129:2006
- DIN EN 62129-1:2016 Calibration of wavelength/optical frequency measurement instruments - Part 1: Optical spectrum analyzers (IEC 62129-1:2016); German version EN 62129-1:2016
- DIN ISO 15472:2020-05 Surface chemical analysis - X-ray photoelectron spectrometers - Calibration of energy scales (ISO 15472:2010); Text in English
- DIN ISO 15472:2020 Surface chemical analysis - X-ray photoelectron spectrometers - Calibration of energy scales (ISO 15472:2010); Text in English
- DIN IEC 61452:2023-02 Nuclear instrumentation - Measurement of activity or emission rate of gamma-ray emitting radionuclides - Calibration and use of germanium-based spectrometers (IEC 61452:2021)
International Organization for Standardization (ISO), How to calibrate the spectrometer
- ISO 15472:2010 Surface chemical analysis - X-ray photoelectron spectrometers - Calibration of energy scales
- ISO 15472:2001 Surface chemical analysis - X-ray photoelectron spectrometers - Calibration of energy scales
- ISO 23547:2022 Measurement of radioactivity — Gamma emitting radionuclides — Reference measurement standard specifications for the calibration of gamma-ray spectrometers
- ISO 17973:2016 Surface chemical analysis - Medium-resolution Auger electron spectrometers - Calibration of energy scales for elemental analysis
- ISO 17973:2002 Surface chemical analysis - Medium-resolution Auger electron spectrometers - Calibration of energy scales for elemental analysis
- ISO/CD 5861 Surface chemical analysis — X-ray photoelectron spectroscopy — Method of intensity calibration for quartz-crystal monochromated Al Kα XPS instruments
- ISO/DIS 5861:2023 Surface chemical analysis — X-ray photoelectron spectroscopy — Method of intensity calibration for quartz-crystal monochromated Al Kα XPS instruments
- ISO 17974:2002 Surface chemical analysis - High-resolution Auger electron spectrometers - Calibration of energy scales for elemental and chemical-state analysis
中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会, How to calibrate the spectrometer
- GB/T 22571-2017 Surface chemical analysis—X-ray photoelectron spectrometers—Calibration of energy scales
Guangdong Provincial Standard of the People's Republic of China, How to calibrate the spectrometer
- DB44/T 1496.1-2014 Calibration method of LED test instrument Part 1: Integrating sphere spectrum test system
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China, How to calibrate the spectrometer
- GB/T 22571-2008 Surface chemical analysis.X-ray photoelectron spectrometers.Calibration of energy scales
KR-KS, How to calibrate the spectrometer
Korean Agency for Technology and Standards (KATS), How to calibrate the spectrometer
- KS C IEC 61452-2017(2022) Nuclear instrumentation — Measurement of gamma-ray emission rates of radionuclides — Calibration and use of germanium spectrometers
- KS D ISO 17973-2011(2021) Surface chemical analysis-Medium-resolution Auger electron spectrometers-Calibration of energy scales for elemental analysis
- KS D ISO 17973:2011 Surface chemical analysis-Medium-resolution Auger electron spectrometers-Calibration of energy scales for elemental analysis
- KS D ISO 17974-2011(2021) Surface chemical analysis-High-resolution Auger electron spectrometers-Calibration of energy scales for elemental and chemical-state analysis
- KS D ISO 17974:2011 Surface chemical analysis-High-resolution Auger electron spectrometers-Calibration of energy scales for elemental and chemical-state analysis
IEEE - The Institute of Electrical and Electronics Engineers@ Inc., How to calibrate the spectrometer
- IEEE N42.14-1991 Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of Radionuclides
Institute of Electrical and Electronics Engineers (IEEE), How to calibrate the spectrometer
- ANSI Std N42.14-1991 American National Standard Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of Radionuclides
- IEEE/ANSI N42.14-1999 Calibration and use of germanium spectrometers for the measurement of gammma-ray emission rates of radionuclides