13.220.20 防火 标准查询与下载



共找到 1593 条与 防火 相关的标准,共 107

BS EN 12845-3. Fixed firefighting systems. Automatic sprinkler systems - Part 3. Guidance for earthquake bracing

ICS
13.220.20
CCS
发布
2022-07-07
实施
2022-07-07

本文件规定了灭火器的维修条件、维修步骤、报废与回收、运输等技术要求。 本文件适用于干粉灭火器、二氧化碳灭火器、水基灭火器和洁净气体灭火器维修管理。

Code of practice for fire extinguisher maintenance management

ICS
13.220.20
CCS
N7810
发布
2022-07-05
实施
2022-07-06

Fire detection and alarm systems — Part 12: Line type smoke detectors using a transmitted optical beam

ICS
13.220.20
CCS
发布
2022-06-13
实施

BS EN 12259-12. Fixed firefighting systems. Components for sprinkler and water spray systems - Part 12. Pumps

ICS
13.220.20
CCS
发布
2022-06-02
实施
2022-06-02

1.1 These requirements cover check valves of 1 NPS and larger, used in piping systems supplying water for fire protection service. 1.2 The check valves covered by these requirements are intended for installation and use in accordance with the Standards for: a) Low-, Medium-, and High-Expansion Foam, NFPA 11; b) Installation of Sprinkler Systems, NFPA 13; c) Installation of Standpipe and Hose Systems, NFPA 14; d) Water Spray Fixed Systems for Fire Protection, NFPA 15; e) Installation of Foam-Water Sprinkler and Foam-Water Spray Systems, NFPA 16; f) Installation of Stationary Pumps For Fire Protection, NFPA 20; g) Water Tanks for Private Fire Protection, NFPA 22; h) Installation of Private Fire Service Mains and Their Appurtenances, NFPA 24; i) Water Mist Fire Protection Systems, NFPA 750; and j) Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height, NFPA 13R. 1.3 Check valves covered by these requirements are intended for installation and use in accordance with, but not limited to the National Fire Code of Canada (NFC), and the National Building Code of Canada (NBC).

Check Valves for Fire-Protection Service

ICS
13.220.20
CCS
发布
2022-06-02
实施

ISO 21927-8:2017 applies to smoke control dampers, placed on the market and intended to operate as part of a pressure differential system or smoke and heat control system. This document specifies requirements and gives reference to the test methods defined for smoke control dampers and their associated components, such as actuators which are intended to be installed in such systems in buildings. Furthermore, provision on marking and information on installation and maintenance of these products are also given. ISO 21927-8:2017 distinguishes between two categories of smoke control dampers, i.e. single-compartment smoke control dampers and multi‑compartment fire-resisting smoke control dampers. Smoke control dampers covered by this document can be installed into smoke control system ducts or onto the ducts' surface. They can be installed also into a wall, floor or ceiling/roof elements or onto the surface of these elements. NOTE To avoid duplication, reference is made to a variety of other standards. To this end, this document can be read in conjunction with EN 13501‑4, EN 1366‑10 and ISO 10294‑1 for details of the furnace testing. ISO 21927-8:2017 does not consider in detail the detrimental and/or corrosive effects that can be caused by process chemicals present in the atmosphere, which are drawn through the system intentionally or inadvertently.

Smoke and heat control systems — Part 8: Smoke control dampers

ICS
13.220.20
CCS
发布
2022-05-12
实施

This document applies to powered smoke exhaust systems in spaces with a large area and with a ceiling height of minimum 3 m, in which smoke protection is required. It includes tables and calculation methods for the design of clear layers in order to comply, inter alia, with the requirements of various protection objectives. This document includes information and provisions concerning the requirements for powered smoke exhaust systems, their design and rules for their installation. NOTE The requirements for testing the ventilators are dealt with in ISO 21927‑3. Other parts of the ISO 21927 series of standards deal with the power supply (ISO 21927‑10), control equipment (ISO 21927‑9) and smoke control ducts and smoke control dampers (ISO 21927‑7 and ISO 21927-8 respectively). Design, as specified in this document, does not apply to: — spaces with fixed gas extinguishing systems; — storage facilities for hazardous materials; — spaces in which there is a risk of explosions; — corridors; — stairwells.

Smoke and heat control systems — Part 5: Powered smoke exhaust systems — Requirements and design

ICS
13.220.20
CCS
发布
2022-05-12
实施

ISO 7240-5:2018 specifies the requirements, test methods and performance criteria for point type heat detectors for use in fire detection and fire alarm systems for buildings (see ISO 7240‑1). For other types of heat detector, or for detectors intended for use in other environments, this document can be used for guidance only. Heat detectors with special characteristics and developed for specific risks are not covered by this document.

Fire detection and fire alarm systems — Part 5: Point type heat detectors

ICS
13.220.20
CCS
发布
2022-05-12
实施

ISO 7240-2:2017 specifies requirements, test methods and performance criteria for fire detection control and indicating equipment (FDCIE) for use in fire detection and fire alarm systems installed in buildings. For the testing of other types of FDCIE, this document is intended to be used only for guidance. FDCIE with special characteristics, developed for specific risks, are not covered in ISO 7240-2:2017.

Fire detection and alarm systems — Part 2: Fire detection control and indicating equipment

ICS
13.220.20
CCS
发布
2022-05-12
实施

This document specifies performance requirements, grooving dimensions, test methods and marking requirements for couplings used in the joining of grooved steel tubes, pipes, grooved-end fittings and other grooved-end components up to 300 DN nominal diameter.

Fire protection — Automatic sprinkler systems — Part 12: Requirements and test methods for grooved-end components for steel pipe systems

ICS
13.220.20
CCS
发布
2022-05-12
实施

1 术语和定义 2 产品结构和参数 3 一般要求 4 技术要求 5 试验方法 6 标志、包装、运输、贮存

Technical specification for anti freezing aboveground fire hydrants

ICS
13.220.20
CCS
C359
发布
2022-05-12
实施
2022-05-26

This document specifies construction requirements, performance requirements, test methods and marking requirements for typical types of pipe hangers.

Fire protection — Automatic sprinkler systems — Part 11: Requirements and test methods for pipe hangers

ICS
13.220.20
CCS
发布
2022-05-12
实施

1 术语和定义 2 产品结构和参数 3一般要求 4 技术要求 5 试验方法 6标志、包装、运输和贮存

Technical specification for anti-collision aboveground fire hydrants

ICS
13.220.20
CCS
C359
发布
2022-05-12
实施
2022-05-26

ISO 21927-7:2017 applies to smoke control duct sections placed on the market and intended to operate as part of a pressure differential system or smoke and heat exhaust system. This document specifies requirements and gives reference to the test methods defined for smoke control duct sections and their associated components (for example, hangers and other items proven at the time of testing), which are intended to be installed in such systems in buildings. Furthermore, marking and information on installation and maintenance of these products are also given in this document. NOTE To avoid duplication, reference is made to a variety of other standards. To this end, this document can be read in conjunction with EN 1366‑8, EN 1366‑9 and ISO 6944‑1, for details of the fire resistance testing and EN 13501‑4 for corresponding classification. ISO 21927-7:2017 has not considered in detail the detrimental and/or corrosive effects that may be caused by process chemicals present in the atmosphere, which are drawn through the system intentionally or inadvertently. ISO 21927-7:2017 also governs associated components used together with smoke control duct sections such as turning vanes and silencers, with the exception of natural and powered smoke ventilators and smoke control dampers, which are covered by separate standards. Ducts for use other than in smoke and heat exhaust/control systems are not covered by this document.

Smoke and heat control systems — Part 7: Smoke ducts sections

ICS
13.220.20
CCS
发布
2022-05-12
实施

1 术语和定义 2 产品结构和参数 3 一般要求 4技术要求 5 试验方法 6标志、包装、运输和贮存

Technical specification for leak proof aboveground fire hydrants

ICS
13.220.20
CCS
C359
发布
2022-05-12
实施
2022-05-26

ISO 7240-4:2017 specifies requirements, test methods and performance criteria for power supply equipment (PSE) for use in fire detection and alarm systems installed in buildings. For the testing of other types of the PSE, this document is intended to be used only for guidance. The PSE with special characteristics, developed for specific risks, are not covered in ISO 7240-4:2017.

Fire detection and alarm systems — Part 4: Power supply equipment

ICS
13.220.20
CCS
发布
2022-05-12
实施

This document specifies performance requirements, methods of test, and marking requirements for open water spray nozzles. This document is not applicable to open sprinklers or open water mist nozzles. Factors of installation, such as nozzle spacing, design densities, wind and hot gas velocities, are not intended to be addressed by this document.

Fire protection — Automatic nozzle systems — Part 14: Requirements and test methods for water spray nozzles

ICS
13.220.20
CCS
发布
2022-05-12
实施

Fire detection and alarm systems — Part 9: Test fires for fire detectors

ICS
13.220.20
CCS
发布
2022-04-28
实施

本文件规定了消防物联网系统数据服务商提供基于大数据分析的消防安全管理数据服务活动相关的服务、管理以及评价要求。 本文件适用于消防物联网系统数据服务商规范其服务活动和自我评价,也适用于认证机构及相关方开展第三方认证及符合性评价活动。

Data service requirements for administration of fire safety based on big data analytics

ICS
13.220.20
CCS
O8290
发布
2022-04-25
实施
2022-04-30

1 术语和定义 2 总体要求 3 试验方法 4 标志、包装、运输和贮存。

Technical Specification for intelligent sprinkler heads for fire protection

ICS
13.220.20
CCS
C359
发布
2022-04-25
实施
2022-05-26



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved