17.120.01 流体流量的测量综合 标准查询与下载



共找到 142 条与 流体流量的测量综合 相关的标准,共 10

  Scope is not provided for this standard

Pipe provers for verification and calibration of measuring systems for liquids

ICS
17.120.01
CCS
发布
2023-09-10
实施

本标准按照GB/T 1.1—2020的规定进行编写,相关内容经过了验证,具有较强的可操作性和科学性。根据调研情况、意见收集情况分析,确定标准的主要技术内容包括: 1.明确燃气表智能化检定无人实验室建设的相关术语和定义。 2.明确无人实验室建设总则,包括基本要求、选址要求、通用建设要求、功能分区规定。 3.明确无人实验室建设的施工组织要求,包括对机构、人员组织,设备、工具、材料管理,技术管理,施工界面跟踪以及资料管理的规定。 4.明确样品传输系统建设要求,包括对码垛传输系统、箱体传输系统及燃气表传输系统的要求,同时各传输系统的传输速度应相互匹配。 5.明确燃气表自动检测系统建设要求,包括通用要求以及对密封性检测、功能检查、压力损失检测、示值误差检测等的要求。 6.明确智能辅助工作系统建设要求,包括功能要求以及检定合格与不合格的燃气表分拣要求,功能要求为实现燃气表检定前以及检定完成后辅助工序的智能化。

Specifications for the construction of unmanned laboratories for intelligent calibration of gas meters

ICS
17.120.01
CCS
D451
发布
2023-08-29
实施
2023-08-29

本标准主要技术内容说明如下: 1. 适用范围 本文件规定了燃气表智能化检定无人实验室运行的术语和定义、工作流程、运行管理和应急要求。本文件适用于燃气表智能化检定无人实验室运行过程。 2. 工作流程 实验室的总体工作流程按以下顺序: a) 将将整垛待检燃气表送到样品传输系统上进行输送、拆垛、拆箱和被检表的定位; b) 被检表通过智能辅助工作系统进行拆防尘帽和外观检测处理; c) 被检表送入燃气表自动检测系统按照JJG 577或JJG 1190要求进行密封性、功能检查、压力损失、示值误差等检测,合格品和不合格品分开放置; d) 智能辅助工作系统对合格品进行装防尘盖、扫条码和装箱操作,满箱后盖上上保护垫、封箱、贴标、捆包、码垛和整垛缠绕; e) 码垛好的被检表整垛送到样品传输系统输送至下线处运走。 3. 运行管理 装置要按环境要求和运行要求进行运行,并配备巡检人员和辅助检定人员。 4. 应急要求 a) 检测过程中出现警报,系统若不能及时停止,运作辅助检定人员(或巡检人员)应立刻判断是否停止相关设备,然后根据系统提示的异常情况进行处理。 b) 遇突发情况需要急停时,辅助检定人员(或巡检人员)应按下设备的“急停”开关。 c) 应建立应急预案体系,编制应急预案,且应每半年至少组织1次生产安全事故应急演练并记录存档。

Operation specifications of unmanned laboratory for intelligent calibration of gas meters

ICS
17.120.01
CCS
D451
发布
2023-08-29
实施
2023-08-29

本标准主要技术内容说明如下: 1. 适用范围 本文件规定了燃气表智能化检定无人实验室的术语和定义、智能化检定无人实验室的维护保养规范、基本要求和过程要求。本文件适用于燃气表智能化检定无人实验室维护保养过程。 2. 总体要求 (1) 基本要求 ①仪器设备维护保养应符合仪器设备操作(使用)说明书的要求。 ②仪器设备维护保养应满足GB/T 27025的相关要求。 ③仪器设备维护保养应满足政府法律法规及行业管理部门的特殊要求。 ④操作人员应进行授权,负责仪器设备清洁、润滑、紧固、检查等。  (2) 样品传输系统维护保养要求 ①传输系统零部件齐全。 ②系统的管道、阀门、接口等部分清洁干净。 ③系统传输衔接性好,起承转接平滑顺畅。 (3) 智能辅助工作系统维护保养要求 ①智能辅助工作系统零部件齐全。 ②系统的活动零部件连接可靠,拆垛取箱、拆箱取表、取防尘帽以及检定完成后自动盖防尘帽、打印粘贴合格标识、放表装箱、打包封箱、码垛缠膜等自动化、无人化辅助工序执行准确到位。 (4) 燃气表自动检测系统维护保养要求 ①自动检测系统零部件齐全。 ②燃气表外观、示值误差、密封性、压力损失以及功能检查全部检测功能正常执行。 3. 维护保养范围 (1) 识别内容 ①实验室应对以下内容进行识别: ? 纳入质量技术管理且需要进行维护保养的仪器设备; ? 确认已识别的仪器设备的维护保养技术内容和方法。 ②若实验室不能独立完成5.1的识别内容,可与销售商或提供维护服务的供应商共同完成。 (2) 仪器设备维护保养清单 根据5.1的内容,建立仪器设备维护保养清单,清单内容包括但不限于: ? 名称、型号、唯一性标识; ? 存放地点; ? 环境要求; ? 维护保养周期; ? 维护保养人; ? 维护保养作业指导书文件名及编号; ? 仪器设备的使用寿命; ? 维修保养历史记录。 (3) 维护保养程序 应有处理、运输、储存、使用和按计划维护设备的程序,以确保其功能正常并防止污染或性能退化。 4. 维护保养作业指导书 (1) 实验室一般需编制仪器设备维护保养作业指导书。作业指导书应由具有二级及以上注册计量师或具有中级及以上职称的人员编制。实验室定期进行维护保养操作人员的培训和技能评估。 (2) 作业指导书的编制、使用、修改,可寻求提供维护服务的供应商的技术支持。作业指导书的更新和修订应及时进行,并记录修订的日期和版本号。  (3) 作业指导书内容应包含以下内容 ? 目的; ? 适用范围; ? 职责; ? 引用文件; ? 使用的工具、试剂、耗材; ? 维护保养内容; ? 维护保养具体要求和步骤; ? 维护保养周期; ? 维护保养后的要求; ? 维护保养记录表格; ? 异常情况的处理方法和报告流程。 5. 维护保养操作 (1) 通用要求 ①应按照作业指导书进行实验室设备维护保养操作。 ②维护保养应做好相关记录并存档。 ③作业指导书中若对仪器设备维护保养有验证要求的,应进行验证。 ④应控制适宜的温度和湿度,保持实验室合适的工作环境。 ⑤建立包括设备档案维护保养记录等内容的记录和文档档案。 ⑥定期清洁、润滑和保养系统的各个部件。 ⑦出现故障或异常情况应参考仪器设备操作(使用)说明书、维护手册或联系专业技术人员进行故障排查和维修。 (2) 样品传输系统 ①使用适当的清洁剂和工具,定期对样品传输系统的各部分进行清洁。 ②定期检查管道连接处的密封性。如发现泄漏应及时进行维修或更换密封件。 ③根据仪器设备操作(使用)说明书使用适当的润滑剂定期对传动部件进行润滑。 ④通过自检程序或专业人员定期对样品传输系统进行检查和测试。 (3) 智能辅助工作系统 ①定期检查智能辅助工作系统的各个部件是否正常工作。 ②定期检查程序是否需要更新与优化。 (4) 燃气表自动检测系统维护保养 ①按照计量检定规程或计量技术规范对相关仪器进行周期检定或校准。 ②定期检查系统的各个部件是否正常工作或需要更新,如发现故障或异常情况,及时进行维修或更换受损部件。 ③定期检查程序是否需要更新与优化。

Maintenance specifications for unmanned laboratory for intelligent calibration of gas meters

ICS
17.120.01
CCS
D451
发布
2023-08-29
实施
2023-08-29

本标准主要技术内容说明如下: 1. 适用范围 本文件规定了燃气表智能化检定无人实验室验收的术语和定义、验收内容和验收流程。本文件适用于燃气表智能化检定无人实验室验收过程。 2. 验收内容 验收内容应包含但不限于:清点设备和材料供货数、试运行配套软件、检查配套基础设施改造情况。 3. 验收流程 验收流程包括验收准备、验收实施和完善项目验收资料归档三部分。

Acceptance specifications for unmanned laboratories for intelligent calibration of gas meters

ICS
17.120.01
CCS
D451
发布
2023-08-29
实施
2023-08-29

本标准按照GB/T 1.1—2020的规定进行编写,相关内容经过了验证,具有较强的可操作性和科学性。根据调研情况、意见收集情况分析,确定标准的主要技术内容包括: 1.明确供水计量失准水量退补的相关术语和定义,包括水量计量装置、水量计量超差、供水计量失准、超差值、失准期间基准水量、退补水量等。 2.明确计量失准类别,包括水量计量超差和水量计量错误两大类,大类下又分若干小类。 3.明确退补水量的确定方法。首先明确超差值的确定方法;然后明确失准期间基准水量的确定,包括水量计量超差情况下基准水量的确定以及“水量计量装置故障”、“水量计量装置参数设置错误”和“数据抄录、采集、传输、储存、处理或计算错误”等3类水量计量错误情况下的基准水量确定方法;最后明确退补水量的计算方法,包括直接计算法、参照计算法和比较计算法。 4.明确计量失准退补要求,包括对供、用水双方的要求。 5.为了供用水双方更好地理解和应用本标准,在附录A中列出了5类供水计量失准的退补水量计算示例。

Specification for refund or supplement of water volume in inaccurate water metering

ICS
17.120.01
CCS
N762
发布
2023-05-08
实施
2023-05-08

On-line test method for metering characteristics of water intake metering system

ICS
17.120.01
CCS
N 12
发布
2022-10-14
实施
2022-11-15

1.1 This test method covers an index test that covers laboratory measurement of flux through saturated geosynthetic clay liner (GCL) specimens using a flexible wall permeameter. 1.2 This test method is applicable to GCL products having geotextile backing(s). It is not applicable to GCL products with geomembrane backing(s), geofilm backing(s), or polymer coating backing(s). 1.3 This test method provides a measurement of flux under a prescribed set of conditions that can be used for manufacturing quality control. The test method can also be used to check conformance. The flux value determined using this test method is not considered to be representative of the in-service flux of GCLs. 1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Measurement of Index Flux Through Saturated Geosynthetic Clay Liner Specimens Using a Flexible Wall Permeameter

ICS
17.120.01
CCS
发布
2022-10-01
实施

本文件规定了平原河流固定式声学多普勒低流速测验的总则、仪器设备要求/安装、流速比测率定、相关定线及检查与保养的要求。

Specification for stationary acoustic doppler flow measurement of rivers in low flow rate plain

ICS
17.120.01
CCS
N764
发布
2022-09-29
实施
2022-09-29

1.1 This test method covers a laboratory procedure for the quantitative determination of the flow rate of a specific volume of a free-flowing metal powder or lubricated powder mixture. 1.2 Units—With the exception of the values for mass, volume, and density, for which the use of the gram and the cubic centimetre unit is long-standing industry practice, the values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Volumetric Flow Rate of Metal Powders Using the Arnold Meter and Hall Flowmeter Funnel

ICS
17.120.01
CCS
发布
2022-09-01
实施

On-line detection method of pipeline-type water intake metering facilities

ICS
17.120.01
CCS
A 50
发布
2022-08-02
实施
2023-02-01

1 范围 本文件规定了回转动力泵性能远程试验的方法。 本文件适用于回转动力泵(离心泵、混流泵和轴流泵)的远程试验。其它类型泵的远程试验参照执行。 2 规范性引用文件 下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。其中,注日期的引用文件,仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB/T 3214  水泵流量的测定方法 GB/T 3216  回转动力泵  水力性能验收试验  l级、2级和3级 GB/T 12785 潜水电泵 试验方法  SL 548     泵站现场测试与安全检测规程 3 术语和定义 下列术语和定义适用于本文件。 3.1 性能试验 performance  test 回转动力泵性能试验包括水力性能试验、汽蚀性能试验和运转试验。 3.2 远程测试 remote  test 对符合试验条件的异地回转动力泵,采用远传通讯、数据云储和远程控制手段完成的性能试验。 3.3 数据采集装置 data acquisition device 回转动力泵试验中,将仪表及变送器的各参数量通过标准接口进行采集、转化、存储、发射的装置。 3.4 数据接收装置 data receiving device 回转动力泵试验中,能够接收数据采集装置发射的信号并能读取各参数原始数据的装置。 4 试验条件 4.1 系统组成 回转动力泵性能远程试验系统包括:测试管路、仪器仪表、数据采集装置、数据云平台、数据接收装置、测试软件、通讯网络。 4.2 测试管路 回转动力泵测试管路分为开式测试管路和闭式测试管路,测试管路应符合GB/T 3216和SL 548中的规定,实现对回转动力泵性能测试要求。 4.3 仪器仪表 现场仪器仪表应具有数据显示功能,并带有输出接口。 用于测量的仪器仪表应有检定或校准证书,并应按规定周期检定或校准。 用于测量的仪器仪表应具有标准通讯接口,变送器或传感器应具有4~20mA或0~5V的输出信号。 用于测量的仪器仪表的测量精度应满足GB/T 3216或GB/T 12785中规定要求。 4.4 试验系统不确定度等级 试验系统的不确定度等级应不低于GB/T 3216和GB/T 12785中2级精度要求。 试验系统不确定度等级应由具备相应资质的检验检测机构评定。 4.5 通讯网络及安全 测试现场的测量设备的输出信号传输到数据采集装置。数据采集装置发出的信号传递到数据云平台上。数据接收装置从数据云平台上接收原始数据,该原始数据显示在测试软件界面上。 现场采集到的原始数据经数据采集装置,通过数据云平台远程传输到检测机构的数据接收装置,在远传过程中须对数据加密处理,保证原始数据的安全性。 4.6 介质 试验介质为“清洁冷水”,其特性应符合表1的规定。 表1 “清洁冷水”特性 特 性 单 位 最大值 温度 ℃ 40 运动黏度 m2/s 1.75×10-6 密度 kg/m3 1050 不吸水的游离固体含量 kg/m3 2.5 溶解于水的固体含量 kg/m3 50 4.7 波动 如果泵的设计或运转使得测量数值出现大幅度的波动,则可以在测量仪表中或其连接管线中设置一种能使波动幅度降低到表2给定值范围内的缓冲装置来进行测量。缓冲装置应是对称和线性的,例如毛细管,它应提供至少是包含了一个完整的波动周期内的积分值。 原始数据的波动应满足表2中的要求: 表2 容许波动幅度,以测量量平均值的百分数表示 测量量 容许波动幅度  1级 % 2级 % 3级 % 流量 ±2 ±3 ±6 压差 ±3 ±4 ±10 出口压力 ±2 ±3 ±6 入口压力 ±2 ±3 ±6 输入功率 ±2 ±3 ±6 转速 ±0.5 ±1 ±2 转矩 ±2 ±3 ±6 温度 0.3℃ 0.3℃ 0.3℃ 4.8 总体的不确定度 表3给出了总体的不确定度e的容许值。 注:本文件规定的总体不确定度等同于扩展测量不确定度(见JJF 1001)。 表3 系统不确定度eS的容许相对值 测量量 最大容许系统不确定度 (保证点)  1级 % 2级和3级 % 流量 ±1.5 ±2.5 压差 ±1.0 ±2.5 出口压力 ±1.0 ±2.5 入口压力 ±1.0 ±2.5 NPSH试验的入口压力 ±0.5 ±1.0 驱动机输入功率 ±1.0 ±2.0 转速 ±0.35 ±1.4 转矩 ±0.9 ±2.0 5 试验 5.1 试验要求 试验的持续时间应能保证获得与要求达到的精度等级相一致的结果。 所有的测量均应达到GB/T 3216规定的稳定运转条件方可进行。 当不能满足这些条件时,测量应由有关各方协商确定。 如果由于特殊的原因,需要确定某一工作条件范围内的性能,则测量点的数量应能满足确定测量不确定度范围内性能的要求。 扬程的调节应在出口管路中进行节流来获得试验条件。 5.2 试验准备 试验前,应检查被试泵安装质量,试验装置及设备,检查数据采集装置和数据接收装置通讯功能,以保证各项试验能顺利进行。 5.3 性能试验 5.3.1 水力性能试验 5.3.1.1  试验步骤 离心泵应从零流量开始,逐步增大至阀门全开。混流泵、轴流泵应从阀门全开状态开始,逐步减少至流量保证点的60%以下。期间应取13~15个不同流量点。所取流量点中应包含有流量保证点QG、95%QG、105%QG、泵工作范围的小流量点Qmin、大流量点Qmax和额定流量点。对离心泵还应包括零流量点。 5.3.1.2  验收等级和容差系数 表4中给出了泵扬程、流量、功率和效率的保证点验收等级。所有的容差系数均以保证值的百分数表示。 回转动力泵性能远程测试验收等级应不低于表4中的2B级。 表4 泵试验验收等级和相应的容差系数值 等级 1 2 3 保证要求 ΔτQ 10% 16% 18%  ΔτH 6% 10% 14%  验收等级 1U 1E 1B 2B 2U 3B  τQ +10% ±5% ±8% +16% ±9% 强制 τH +6% ±3% ±5% +10% ±7%  τP +10% +4% +8% +16% +9% 可选 τη ≥0% -3% -5% -7%  注:τx(x=Q,H,P,η)代表指示数量的容差系数。 5.3.2  汽蚀性能试验 5.3.2.1  试验方法      回转动力泵汽蚀性能试验方法按照表5规定进行。 表5 确定NPSH3的方法 装置类型 开式池 开式池 开式池 开式池 开式池 闭式回路 闭式回路 闭式回路 闭式槽或闭式回路 独立变化的量 入口节流阀 出口节流阀 水位 入口节流阀 水位 罐中压力 温度(汽化压力) 罐中压力 温度(汽化压力) 恒定的量 出口节流阀 入口节流阀 入口和出口节流阀 流量 流量 流量 流量 入口和出口节流阀 随调节而变的量 扬程、流量、NPSHA,水位 扬程、流量、NPSHA,水位 扬程、流量、NPSHA NPSHA、扬程、出口节流阀(为使流量恒定) NPSHA、扬程、出口节流阀 扬程、NPSHA、出口节流阀(当扬程开始下降时为使流量恒定) NPSHA、扬程、出口节流阀(当扬程开始下降时为使流量恒定) —NPSHA; —汽蚀达到一定程度时扬程和流量 扬程-流量 和NPSH特性曲线 NPSH- 流量特性曲线    5.3.2.2  试验步骤 试验时,采用逐渐降低NPSH直至恒定流量下的扬程的下降达到3%。此时的NPSH值即为NPSH3(见表5)。 5.3.2.3  容差系数 测得的NPSHR值不应超出保证的NPSHR值。

Performance remote test for rotodynamic pumps—test method

ICS
17.120.01
CCS
C344
发布
2022-06-15
实施
2022-09-26

Standard Test Method for Measurement of Index Flux Through Saturated Geosynthetic Clay Liner Specimens Using a Flexible Wall Permeameter

ICS
17.120.01
CCS
发布
2022-05-01
实施

Guidelines for Water Balance Testing of Service Water Units

ICS
17.120.01
CCS
P41
发布
2021-12-28
实施
2022-04-01

本文件规定了加油站内燃油加油机(以下简称加油机)管理的术语和定义、加油站对加油机的管理要求和加油机的检校管理要求。 本文件适用于加油站用于贸易结算的加油机管理。 公司内部加油站也可以参照本文件管理加油机。

Management specification for fuel dispensers in gas stations

ICS
17.120.01
CCS
C359
发布
2021-12-27
实施
2022-01-05

本文件规定了氦质谱检漏仪的术语和定义、性能要求及检测方法。

Performance requirements and test method for helium mass spectrometer leak detector

ICS
17.120.01
CCS
M732
发布
2021-12-17
实施
2021-12-17

本文件适用于廊坊辖区内测量江河、湖泊、水库、水利实验室引流用渠道及堰、槽等明渠流量的智能多通道电磁式明渠流量测量系统(以下简称流量测量系统),还适用于封闭管道的不满管液体的流速测量(以下简称流速测量)

Technical specifications for intelligent multi-channel electromagnetic open channel flow measurement system

ICS
17.120.01
CCS
N12
发布
2021-11-15
实施
2021-12-15

本文件规定了超声波水表全自动检定装置(以下简称装置)的组成与原理、分类、一般要求、技术要求、试验方法、检验规则、标识、包装、运输和贮存等内容。 本文件适用于DN15、DN20、DN25、DN32、DN40口径超声波水表全自动检定装置。

Technical specification for automatic verification equipment of ultrasonic water meter

ICS
17.120.01
CCS
C3990
发布
2021-10-15
实施
2021-10-20

前  言 1 范围 1 2 规范性引用文件 1 3 术语与定义 1 4 一般规定 3 5 走航式ADCP流量测验 3 5.1 基本要求 3 5.2 仪器安装 5 5.3 仪器自检 5 5.4 外接设备 5 5.5 测前准备 6 5.6 参数设置 7 5.7 畅流期流量测验 9 5.8 冰期流量测验 9 5.9 垂线流速测验 10 5.10 成果检查 10 5.11 数据处理 11 5.12 仪器检查与保养 12 5.13 仪器检验 12 5.14 误差来源与精度要求 12 6 固定式ADCP流量测验 13 6.1 基本要求 13 6.2 H-ADCP安装与设置 14 6.3 V-ADCP安装与设置 15 6.4 比测率定 16 6.5 关系线定线与检验 16 6.6 代表流速关系使用 17 7 ADV流量测验 18 附录A(规范性附录)测验成果记载表 19 附录B(资料性附录)走航式ADCP单次流量计算原理 23 附录C(规范性附录)移动底检测与流量校正 28 附录D(规范性附录)垂线流速拟合 35 附录E(规范性附录)固定式ADCP设置与检查 36

Acoustic Doppler Flow Test Specification

ICS
17.120.01
CCS
XXXX
发布
2021-09-29
实施
2021-12-01

前言 II 1 范围  2 规范性引用文件  3 术语和定义  4 标记  5 技术要求  6 性能指标要求  7 性能指标试验方法  8 检验规则  9标志、包装、运输和贮存 

Box-shaped ultrasonic flow meter for open channels

ICS
17.120.01
CCS
N762
发布
2021-06-10
实施
2022-06-20



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved