共找到 562 条与 明渠中流量的测量 相关的标准,共 38 页
This document specifies a method for the estimation of the sub-critical flow of clear water in a smooth, essentially horizontal channel (or a gently sloping channel), abruptly discontinued at bottom by a hydraulic structure, with a vertical drop and discharging freely. Such an overfall forms a control section and offers a means for the estimation of flow using the end depth measurement method. A wide variety of channel cross-sections with overfall have been studied, but only those which have received general acceptance after adequate research and testing, and therefore do not require in situ calibration, are considered. This document covers channels with the following types of cross-sections: a) rectangular with confined and unconfined nappe; c) triangular; e) parabolic. b) trapezoidal; d) circular; The flow at the brink is curvilinear; therefore, the measured depth at the drop is not equal to the critical depth as computed by the principle based on assumption of parallel flow. However, the end depth and the critical depth (as in the case of the assumption of parallel flow) have unique relation, which is used to estimate the flow through these structures.
Hydrometry - Liquid flow measurement using end depth method in channels with a free overfall
Hydrometry. Stage-fall-discharge relationships
Hydrometry - Measurement of discharge by the ultrasonic transit time (time of flight) method
Hydrometry - Measurement in meandering river and in streams with unstable boundaries
Hydrometry - Measurement of discharge by the ultrasonic transit time (time of flight) method
This document specifies the requirements for the integration of baffles on the downstream face of triangular profile flow measurement structures to aid the passage of fish.
Hydrometry -- Low cost baffle solution to aid fish passage at triangular profile weirs that conform to ISO 4360
This document specifies methods for determining stage-fall-discharge relationships for a stream reach where variable backwater occurs either intermittently or continuously. Two gauging stations, a base reference gauge and an auxiliary gauge are required for gauge height measurements. A number of discharge measurements are required in order to calibrate the rating to the accuracy required by this document. The preparation of rating curves is not described in detail in this document. NOTE For a more detailed description of preparing rating curves, see the methods described in ISO 1100-2.
Hydrometry - Stage-fall-discharge relationships
Hydrometry. Open channel flow measurement using thin-plate weirs
Flow measurement structures - Rectangular, trapezoidal and U-shaped flumes; Amendment 1
This document defines the requirements for the use of rectangular and triangular (V-notch) thin-plate weirs for the measurement of flow of clear water in open channels under free flow conditions. It includes the requirements for the use of full-width rectangular thin-plate weirs in submerged (drowned) flow conditions.
Hydrometry - Open channel flow measurement using thin-plate weirs
Hydrometry. Low cost baffle solution to aid fish passage at triangular profile weirs that conform to ISO 4360
his International Standard specifies methods for the measurement of the flow of water in open channels under steady flow conditions using streamlined triangular profile weirs. The flow conditions considered are free flow, which is dependent on the upstream head only, and drowned flow, which depends on both upstream and downstream water levels.
Measurement of liquid flow in open channels by weirs and flumes -- Streamlined triangular profile weirs
Hydrometry - Low cost baffle solution to aid fish passage at triangular profile weirs that conform to ISO 4360
Hydrometry. Position fixing equipment for hydrometric boats
Hydrometry - Position fixing equipment for hydrometric boats
Hydrometry. Hydrometric data transmission systems. Specification of system requirements
Hydrometry - Hydrometric data transmission systems - Specification of system requirements
Measurement of liquid flow in open channels under tidal conditions
Measurement of liquid flow in open channels-Part 2:Determination of the stage-discharge relation
Liquid flow measurement in open channels by weirs and flumes — Rectangular broad-crested weirs
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved