27.120.30 裂变物质 标准查询与下载



共找到 992 条与 裂变物质 相关的标准,共 67

本标准规定了核设施流出物的监测目的、编制监测计划的原则和要求、采样和测量技术要求以及测量结果的记录、报告和存档要求。本标准适用于涉及处理和加工放射性物质的所有核设施的流出物监测。

The regulations for monitoring effluents at nuclear facilities

ICS
27.120.30
CCS
Z33
发布
1989-03-31
实施
1990-01-01

本标准规定了核辐射环境质量评价的一般原则和应遵循的技术规定。目的是提高核辐射环境质量评价工作的科学性,改善环境质量,保证公众的辐射安全。 本标准适用于应进行核辐射环境质量评价的企、事业单位,这类单位包括: a.核燃料循环系统的各个单位; b.陆上固定式核动力厂和核热电厂; c.拥有生产或操作量相应于甲、乙级实验室(或操作场所)并向环境排放放射性物质的研究、应用单位。

The general regulation for environmental radiological assessment

ICS
27.120.30
CCS
Z33
发布
1989-03-31
实施
1990-01-01

本标准规定了制定和执行核设施流出物和环境放射性监测质量保证计划的一般要求。制定环境非放射性监测质量保证计划亦可参考使用本标准的原则。

General requirements of quality assurance program for effluent and environmental radioactivity monitoring at nuclear facilities

ICS
27.120.30
CCS
Z33
发布
1989-03-31
实施
1990-01-01

Determination of uranium in uranium hexafluoride by gravimetric method

ICS
27.120.30
CCS
F46
发布
1988-12-30
实施
1989-10-01

本标准规定了铀矿石浓缩物的一般技术要求。 本标准适用于铀矿石经水冶处理,生产供出口的浓缩物。

Uranium ore concentrate

ICS
27.120.30
CCS
F45
发布
1988-12-30
实施
1989-10-01

本规范是用航空摄影测量方法测绘1:500、1:1000、1:2000地形图内业作业的依据。按本规范测制的地形图,可供国民经济各部门进行勘察、规划、设计等使用。

Specifications for aerophotogrammetric office operation 1:500,1:1000,1:2000 topographic maps

ICS
27.120.30
CCS
A77
发布
1987-06-10
实施
1988-01-01

本规范是采用航空摄影测量方法测绘1:500、1:1000、1:2000地形图外业作业的依据。按本规范测制的地形图,可供国民经济各部门进行勘察、规划、设计等使用。

Specifications for aerophotogrammetric field work 1:500,1:1000,1:2000 topographic maps

ICS
27.120.30
CCS
A77
发布
1987-06-10
实施
1988-01-01

BS ISO 13465 Nuclear energy. Nuclear fuel technology - Determination of neptunium in nitric acid solutions by spectrophotometry

ICS
27.120.30
CCS
发布
2024-02-02
实施
2024-02-02

BS ISO 6863 Nuclear fuel technology - Preparation of spikes for isotope dilution mass spectrometry (IDMS)

ICS
27.120.30
CCS
发布
2024-01-30
实施
2024-01-30

1.1  This method describes the determination of the isotopic composition, or the concentration, or both, of uranium, plutonium, and americium as nitrate solutions by the total evaporation method using a thermal ionization mass spectrometer (TIMS) instrument. Purified uranium, plutonium, or americium nitrate solutions are deposited onto a metal filament and placed in the mass spectrometer. Under computer control, ion currents are generated by heating of the filament(s). The ion currents are continually measured until the whole deposited solution sample is exhausted. The measured ion currents are integrated over the course of the measurement and normalized to a reference isotope ion current to yield isotope ratios. 1.2  In principle, the total evaporation method should yield isotope ratios that do not require mass bias correction. In practice, samples may require this bias correction. Compared to the conventional TIMS method described in Test Method C1625 , the total evaporation method is approximately two times faster, improves precision of the isotope ratio measurements by a factor of two to four, and utilizes smaller sample sizes. Compared to the C1625 method, the total evaporation method provides “major” isotope ratios 235U/238U, 240Pu/239Pu, and 241Am/243Am with improved accuracy. 1.3  The total evaporation method is prone to biases in the “minor” isotope ratios (233U/238U, 234U/238U, and 236U/238U ratios for uranium materials and 238Pu/239Pu, 241Pu/239Pu, 242Pu/239Pu, and 244Pu/239Pu ratios for plutonium materials) due to peak tailing from adjacent major isotopes. The magnitude of the absolute bias is dependent on measurement and instrumental characteristics. The relative bias, however, depends on the relative isotopic abundances of the sample. The use of an electron multiplier equipped with an energy filter may eliminate or diminish peak tailing effects. Measurement of the abundance sensitivity of the instrument may be used to ensure that such biases are negligible, or may be used to bias correct the minor isotope ratios. 1.4  The values stated in SI units are to be regarded as standard. When non-SI units are provided in parentheses, they are for information only. 1.5  This standard may involve the use of hazardous materials and equipment. This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use. 1.6  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Determination of the Uranium, Plutonium or Americium Isotopic Composition or Concentration by the Total Evaporation Method Using a Thermal Ionization Mass Spectrometer

ICS
27.120.30
CCS
发布
2024-01-26
实施

1.1  This test method covers the determination of 25 elements in plutonium (Pu) materials. The Pu is dissolved in acid, the Pu matrix is separated from the target impurities by an ion exchange separation, and the concentrations of the impurities are determined by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). 1.2  This test method is specific for the determination of impurities in 8 M HNO3 solutions. Impurities in other plutonium materials, including plutonium oxide samples, may be determined if they are appropriately dissolved (see Practice C1168 ) and converted to 8 M HNO3 solutions. 1.3  The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard. Additionally, the non-SI units of molarity and centimeters of mercury are to be regarded as standard. 1.4  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 9 on Hazards. 1.5  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Determination of Impurities in Plutonium: Acid Dissolution, Ion Exchange Matrix Separation, and Inductively Coupled Plasma-Atomic Emission Spectroscopic (ICP/AES) Analysis

ICS
27.120.30
CCS
发布
2024-01-18
实施

Standard Test Method for Gamma Energy Emission from Fission and Decay Products in Uranium Hexafluoride and Uranyl Nitrate Solution

ICS
27.120.30
CCS
发布
2024-01-15
实施

Standard Guide for Nondestructive Assay of Special Nuclear Material (SNM) Holdup Using Passive Neutron Measurement Methods

ICS
27.120.30
CCS
发布
2023-12-01
实施

Standard Practice for Preparation and Dissolution of Plutonium Materials for Analysis

ICS
27.120.30
CCS
发布
2023-10-01
实施

Standard Test Method for Quantitative Determination of 241Am in Plutonium by Gamma-Ray Spectrometry

ICS
27.120.30
CCS
发布
2023-10-01
实施

BS EN ISO 12183. Nuclear fuel technology. Controlled-potential coulometric measurement of plutonium

ICS
27.120.30
CCS
发布
2023-09-27
实施
2023-09-27

Nuclear energy. Determination of Gd2O3 content in gadolinium fuel blends and gadolinium fuel pellets by atomic emission spectrometry using an inductively coupled plasma source (ICP-AES)

ICS
27.120.30
CCS
发布
2023-08-31
实施
2023-08-31

Determination of uranium content in samples coming from the nuclear fuel cycle by L-absorption edge spectrometry

ICS
27.120.30
CCS
发布
2023-08-31
实施
2023-08-31

Nuclear energy — Packagings for the transport of uranium hexafluoride (UF6) — Amendment 1

ICS
27.120.30
CCS
发布
2023-08
实施

Standard Test Method for Isotopic Analysis of Uranium Hexafluoride by Single–Standard Gas Source Multiple Collector Mass Spectrometer Method

ICS
27.120.30
CCS
发布
2023-06-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号