29.035.20 塑料和橡胶绝缘材料 标准查询与下载



共找到 1692 条与 塑料和橡胶绝缘材料 相关的标准,共 113

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 4: Cellulose paper, creped and non-creped, with rubber thermosetting adhesive

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 8: Woven fabric tapes with pressure-sensitive adhesive based on glass, cellulose ace

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 14: Polytetrafluoroethylene film tapes with pressure-sensitive adhesive

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 19: Tapes made from various backing materials with pressure-sensitive adhesive on bo

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 8: Woven fabric tapes with pressure-sensitive adhesive based on glass, cellulose ace

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 19: Tapes made from various backing materials with pressure-sensitive adhesive on bo

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 19: Tapes made from various backing materials with pressure-sensitive adhesive on bo

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 4: Cellulose paper, creped and non-creped, with rubber thermosetting adhesive

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 12: Requirements for polyethylene and polypropylene film tapes with pressure sensiti

ICS
29.035.20
CCS
发布
2018-03-06
实施

Pressure-sensitive adhesive tapes for electrical purposes — Part 3: Specifications for individual materials — Sheet 11: Polyester film combinations with glass filament, creped cellulosic paper, polyes

ICS
29.035.20
CCS
发布
2018-03-06
实施

1.1 These test methods cover procedures for testing polytetrafluoroethylene tubing for use as electrical insulation. The procedures appear in the following sections: Procedure Sections ASTM Methods Conditioning 7 ... Dielectric Breakdown Voltage 28 – 30 D149, D876 Inside Diameter 8 – 13 D876 Mandrel Bend Test 46 – 52 D149, D876 Melting Point 41 – 45 D3418, D4895 Penetration Test 26 and 27 D876 Specific Gravity 36 – 40 D792, D1505 Strain Relief 31 – 35 ... Volatile Loss 20 – 25 ... Wall Thickness 14 – 19 ... NOTE 1—These test methods are similar but not identical to those in IEC 60684–2. 1.2 The values stated in inch-pound units are the standard except for temperature, which is stated in degrees Celsius. Values in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see Section 5. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Methods for Polytetrafluoroethylene Tubing

ICS
29.035.20
CCS
/
发布
2018
实施
0000-00-00

1.1 These test methods cover the testing of homogeneous organic polymer films not over 2.4 mm (95 mils) thick that are to be used for electrical insulation. 1.2 These test methods are not necessarily applicable to testing films in combinations with a coating, another film, or with other types of substrate, such as fabrics or papers. 1.3 The values stated in SI units are the standard. The values in parentheses are provided for information only. 1.4 The procedures appear in the following sections: Procedure Sections Conditioning 6 and 7 Dielectric Breakdown Voltage & Dielectric Strength 21 to 26 Extractables 65 to 70 Heat-Seal Strength 59 to 64 Permittivity and Dissipation Factor 42 to 47 Resistance Method for Measuring the Tendency to Corrode Metals 38 to 41 Sampling 5 Shrinkage 48 to 53 Strain Relief 13 to 20 Surface Resistivity 27 to 31 Tensile Properties 12 Thickness 8 to 11 Volume Resistivity 32 to 37 Water Absorption 53 to 58 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. NOTE 1—These test methods are similar to IEC 60674–2. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Methods for Polymeric Films Used for Electrical Insulation

ICS
29.035.20
CCS
/
发布
2018
实施
0000-00-00

1.1 This specification covers acceptance testing of rubber insulating covers for use as portable protective devices for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. It includes insulator hoods, dead-end protectors, line hose connectors, cable end covers, and miscellaneous covers. The electrical, physical, and chemical requirements of this specification shall apply also to any new or modified styles of covers that may be developed for specific purposes. 1.2 Three types of covers, differing in chemical and physical characteristics, are provided, and are designated as Type I, non-resistant to ozone, and Type II and Type III, resistant to ozone. 1.3 Five classes of covers, differing in electrical characteristics, are provided, and are designated as Class 0, Class 1, Class 2, Class 3, and Class 4. 1.4 Five styles of covers, differing in design characteristics, are provided, and are designated as Style A, Style B, Style C, Style D, and Style E. NOTE 1—Because of the use requirements some covers are semi-rigid and others flexible. The flexible devices should remain suitably flexible for application and removal through normal temperatures of − 29 to 54.5°C (−20 to 130°F). 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See 18.2 for a specific cautionary statement. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Rubber Insulating Covers

ICS
29.035.20
CCS
发布
2017-12-15
实施

1.1 This specification covers a crosslinked polyethylene insulation for electrical wires and cables in conductor sizes 14 AWG [2.08 mm2 ] and larger. The base polymer of this insulation consists substantially of polyethylene or a polyethylene copolymer. 1.2 This type of insulation is suitable for continuous use on power cables in wet and dry locations, for voltage ratings not exceeding 2000 V and at conductor temperatures not exceeding 90°C for normal operation. For copper conductors, the insulation can be applied over the uncoated metal. 1.3 Materials covered by this specification are not sunlight and weather resistant unless they are carbon black pigmented or contain an additive system designed for this protection. 1.4 In many instances the insulation cannot be tested unless it has been formed around a conductor. Therefore, tests are done on insulated wire in this standard solely to determine the relevant property of the insulation and not to test the conductor or completed cable. 1.5 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Crosslinked Polyethylene Insulation for Wire and Cable Rated 0 to 2000 V

ICS
29.035.20
CCS
发布
2017-11-01
实施

Electric cables - Accessories - Material characterization - Part 1: Fingerprinting for resinous compounds

ICS
29.035.20
CCS
发布
2017-11-01
实施

Electric cables - Accessories - Material characterization - Part 2: Fingerprinting for heat shrinkable components for low and medium voltage applications up to 20@8/36 (42) kV

ICS
29.035.20
CCS
发布
2017-11-01
实施

Electric cables - Accessories - Material characterization - Part 3: Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20@8/36 (42) kV

ICS
29.035.20
CCS
发布
2017-11-01
实施

1.1 This specification covers crosslinked chlorinated polyethylene (CM) compounds suitable for use as outer coverings or jackets on electrical cables for general-purpose, heavy-duty, and extra-heavy-duty service. 1.2 These jacket materials are not recommended for use on cables which are to be installed at a temperature less than -25°C. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for General-Purpose, Heavy-Duty, and Extra-Heavy-Duty Crosslinked Chlorinated Polyethylene (CM) Jackets For Wire and Cable

ICS
29.035.20
CCS
发布
2017-11-01
实施

This part of IEC 60684 gives the requirements for two types of heat-shrinkable, polyolefin sleeving, stress control, not flame retarded, with a nominal shrink ratio up to 3:1. This sleeving has been found suitable for use up to temperatures of 100 °C. – Type A : Medium wall Internal diameter up to 65,0 mm typically – Type B : Thick wall Internal diameter up to 95,0 mm typically These sleevings are normally supplied in colour black. Since these types of sleevings cover a significantly large range of sizes and wall thicknesses, Tables A.1 and A.2 in this standard provides guidance to the range of sizes available. The actual size shall be agreed between the user and the supplier. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone. This sleeving is designed to be used in MV cable accessories and as such electrical performance must be proven as part of the assembly. Examples of this are described in HD 629 and the IEC 60502 series.

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 282: Heat-shrinkable, polyolefin sleeving - Stress control

ICS
29.035.20
CCS
发布
2017-10-03
实施

This part of IEC 60684 gives the requirements for heat-shrinkable sleevings for oil barrier, medium voltage cable jointing and termination applications, with nominal shrink ratios of up to 3:1. These sleevings have been found suitable for use up to temperatures of 80 °C. Type A: polyolefin based. Type B: fluoropolymer based, enhanced oil resistance. These sleevings are normally supplied as translucent. Since these types of sleevings cover a significantly large range of sizes and wall thicknesses, Annex A, Tables A.1 and A.2, in this document, provide a guide to the range of sizes available. The actual size will be agreed between the purchaser and supplier. Materials which conform to this standard meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this standard alone. This sleeving is designed to be used in MV cable accessories and as such, electrical performance as defined as part of the assembly. Examples of this are described in HD 629 and IEC 60502 series.

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 284: Heat-shrinkable sleevings, for oil barrier applications

ICS
29.035.20
CCS
发布
2017-10-03
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved