本文件规定了电力IMS 交换专网软件终端系统的构成、功能、性能和管理要求。 本文件适用于电力IMS 交换专网软件终端系统的设计、建设和运维管理。

Technical requirements for electric power IMS switching private network software terminal system

ICS
29.240.30
CCS
D4420
发布
2021-06-29
实施
2022-07-02

本文件是 T/CEC 497《智能变电站冗余后备测控装置》的第 1 部分。T/CEC 497 已经发布了以下 部分: ——第1部分:技术要求; ——第2部分:检测要求。

Smart substation redundant backup measurement and control device

ICS
29.240.30
CCS
D4420
发布
2021-06-29
实施
2022-07-02

本文件规定了源网荷协同控制系统紧急切负荷子系统的系统结构、技术要求、控制策略、试验验 证等内容。 本文件适用于源网荷协同控制系统紧急切负荷子系统,并作为该系统的方案设计、策略制定、通 信安防、工程实施、试验验证、运行管理的依据。

General technical specification for emergency load shedding of source-grid-load coordinating control system

ICS
29.240.30
CCS
D4420
发布
2021-03-11
实施
2022-06-21

本标准规定了高压开关设备分合闸线圈电流检测技术的系统组成及功能、性能要求、性能试验、检测实施,以及特征参数计算、分合闸缺陷判别等结果应用要求。本标准适用于高压开关设备的分合闸线圈电流的检测的技术要求、性能检验和现场应用。 本标准共设6章,包括范围;规范性引用文件;术语和定义;检测系统;检测实施;结果应用。标准的主要结构和内容如下: 第1章“范围”,说明标准主要内容和适用范围。 第2章“规范性引用文件”,列出了本标准引用的5项国家标准和1项电力行业标准。 第3章“术语和定义”,给出了分合闸线圈电流检测技术所涉及的术语和定义,便于标准使用者理解电流波形特点和分析数据特征。给出了开关设备首次动作的概念,“首次动作”改变了操动机构之前的长期状态,在首次动作时检测分合闸线圈电流,容易发现操动机构等的潜在问题。 第4章“检测系统”,规范了检测系统的要求,其中4.1节规范了检测系统的组成、各部件的功能要求;4.2节规定了电流和电压采集的性能,提出了范围、准确度、线性度、采样速率、连续测量稳定性、传感器多次开合稳定性和其他性能要求的具体要求;4.3节规定了准确度试验、线性度试验、电流测量稳定性试验、电流测量动态响应试验、电流传感器多次开合稳定性试验、电压测量稳定性试验、电压测量动态响应试验和其他通用性试验等的要求。 第5章“检测实施”,规范了现场实施检测的步骤和注意事项。 第6章“结果应用”,规范了特征参数计算、分合闸过程分析、缺陷判别的方法。 附录A,阐明了分合闸线圈工作原理、分合闸线圈及其控制回路的原理、基于分合闸线圈电流的开关设备缺陷诊断等检测技术原理。 附录B,推荐了检测结果输出的要求。 附录C,给出了若干缺陷参考波形及缺陷的分析判断方法 本标准补充完善了电力设备状态检测领域内高压开关设备分合闸线圈电流检测的技术和应用要求。

Guide of current measurement technology for opening and closing coils of high voltage switchgear

ICS
29.240.30
CCS
C382
发布
2021-02-22
实施
2021-05-06

本标准以电力行业标准《电阻测量装置通用技术条件》(DL/T 845-2004)、 《接装置特性参数测量地导则》(DL/T 475-2017)中的内容为基础,规定了电力系统用接地特性异频测量装置的技术要求和检测方法。 本标准适用于电压等级 6kV~1000kV,40Hz~60Hz 的采用四极法的异频接地阻抗测量仪、异频接地特性测量装置的生产和检验。标准中第5、6章,除了对装置的外观、电气安全和功能要求外,针对采用异频测试装置测量接地特性试验中影响测试精度的各类因素,例如选频电压表、电流表等测量单元精度,辅助电极电阻和供电电源影响,工频干扰信号影响,分别提出了技术要求和具体的检测试验方法以及相应的试验类型和试验周期。 本标准共7章,标准的主要结构和内容如下: 第1章“范围”,主要说明标准制定的目的、主要内容和适用范围。 第2章“规范性引用文件”,列出了本标准引用的标准、规程。 第3章“术语和定义”,对本标准适用的主要术语进行了定义。 第4章“概述”,主要说明电力系统用接地特性异频测量装置的工作原理。 第5章“技术要求”,主要提出电力系统用接地特性异频测量装置的使用技术条件的要求和规范。包括工作条件、外观、电气安全、功能要求、测量误差、装置功率源性能、抗干扰性能、供电电源共8大类要求。 第6章“试验方法”,根据“技术要求”对接地特性异频测量装置的外观、绝缘电阻、绝缘强度、性能检查、接地电阻示值误差、辅助电极影响、选频电压表示值误差、选频电流表示值误差、分流向量测量示值误差、功率源输出波形及频率、功率源输出功率、负荷能力、接地电阻工频地电压干扰、分流向量测量抗工频电流干扰、跨步电压测量抗工频地电压干扰、供电电源影响共16项检测试验内容的方法进行详细的描述。 第7章“试验项目”,规定接地特性异频测量装置的检测试验项目的类型。

Technical specification of different frequency method grounding characteristic measuring device used in the power system

ICS
29.240.30
CCS
C382
发布
2021-02-22
实施
2021-05-06

1、线路故障设置    计量二次回路故障设置 2、RS485通信故障设置     与电能表485通信故障、与采集器485通信故障、与集中器485通信故障 3、表计故障设置     采样单元故障、显示单元故障、通信单元故障、时钟单元故障、计量单元故障 4、集中器终端故障设置     集中器终端硬件单元故障、集中器终端上行通信单元故障、集中器终端下行通信单元故障、集中器终端测量点参数单元故障 5、跨台区故障设置     跨台区物流故障设置、跨台区参数故障设置 6、负荷切割故障设置     符合切割物理故障设置 7、语音计时与显示     语音倒计时与时间显示 8、数据采集     电能表测量点数据采集 9、数据传输     与集中器通信、中继(路由)、数据转发(通信转换) 10、本地功能     运行状态指示、本地维护接口 11、安全保护     过压、过载、短路及漏电保护 12、主站系统     计量自动化系统主站仿真系统 13、多级联调     多级联调联试

Low pressure set copy autonomous operations simulation device

ICS
29.240.30
CCS
C402
发布
2021-01-05
实施
2021-01-12

Input-distributional boards for dwellings and public buildings. General specifications

ICS
29.240.30
CCS
发布
2021-00-00
实施
2022-03-01

本文件规定了电力智能锁具统一接口规范中所含的智能锁具管控系统、电力智能钥匙、电力智能锁具、安全认证规范、编码规范、通讯规范等内容。 本规范适用于变电站、配电房等电力场所的智能锁具应用及管理。

Unified Interface Specification for Power Intelligent Locks

ICS
29.240.30
CCS
D4420
发布
2020-12-22
实施
2022-11-15

本标准规定了电力物联管理平台在连接管理、数据处理、设备管理、应用管理等基础功能方面的技术规范。 本标准适用于电力物联管理平台的制造、检验、使用和验收。

Technical Specifications for Basic Functions of Electric Power IoT Management Platform

ICS
29.240.30
CCS
D4420
发布
2020-12-22
实施
2022-11-15

本标准规定了±800kV及以上电压等级特高压直流保护系统现场测试的种类、周期、应具备的条件、以及测试项目、方法和要求。 本标准适用于±800kV及以上电压等级特高压直流保护系统的安装调试和运行维护等工作,高压直流保护系统的安装调试和运行维护可参考执行。

UHV DC Protection Field Test Guidelines

ICS
29.240.30
CCS
D4420
发布
2020-12-22
实施
2022-11-15

本技术导则规定了柔性直流输电工程控制系统(以下简称控制系统)的通用要求、功能与性能要求、通信接口及对其他设备要求等。 本技术导则适用于背靠背、双端、多端柔性直流输电工程控制系统。

Technical Guidelines for Control System of Flexible DC Transmission Project

ICS
29.240.30
CCS
D4420
发布
2020-06-30
实施
2022-06-05

本文件规定了综合评价配电网发展水平的指标体系结构、指标内容及计算方法、主要指标及目标参考值。 本文件适用于110(66)kV 及以下配电网发展水平综合评价。

Guidelines for Comprehensive Evaluation of Distribution Network Development Level

ICS
29.240.30
CCS
D4420
发布
2020-06-30
实施
2022-06-05

1 Scope 1.1 This Standard applies to permanently connected, single or multi-branch circuit, multi-circuit output, solid-state lighting controls rated at 600 V and less, 50 or 60 Hz; single or three phase; with or without overcurrent protection on the load side; with or without integral load switching devices; designed to be used as a complete solid-state lighting control system for the purpose of controlling a single type or multiple types of lighting loads, such as a) incandescent lamps; b) magnetic ballasts; c) fluorescent, compact fluorescent, and electric discharge lamps; d) HID (pilot duty) and electronic ballasts; e) LED and OLED lights and drivers; and f) 0 to 10 V dc analog dimming and intended for installation in accordance with CSA C22.1, Canadian Electrical Code, Part I, and NFPA 70, National Electrical Code (NEC). 1.2 This Standard also applies to SSCLS products mounted in a portable manner. Note: “Mounted on wheels” can include wheel-mounted equipment that can be moved by one person, up to large truck- or trailer-mounted assemblies. Similarly, “mounted on skids” can include equipment that is small enough and light enough to be moved by one person, up to large or heavy units that can only be skidded with larger towing vehicles or lifted and moved with hoists or cranes. 1.3 This Standard applies to ac rated controls for which the load rating does not exceed 40 A per circuit at a maximum of 600 V. 1.4 SSCLS products may include receptacles of configuration 5-15R, 5-20R, and L5-20R, used as lighting load connection points, with access limited to qualified personnel only. 1.5 SSCLS products may include convenience receptacles, mechanical switches, dimming circuits, and other wiring devices on separate circuits. 1.6 SSCLS products may include NC (normally closed) or NO (normally open) contacts for the purpose of controlling other general-use loads rated inductive, resistive, and 2 hp or less. 1.7 SSCLS products may include a Class 2 power supply for the purpose of feeding power to analog or digital inputs, such as sensors. 1.8 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.9 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Solid-state controls for lighting systems (SSCLS)

ICS
29.240.30
CCS
发布
2020-02-01
实施

Casting clamps for transmission line use

ICS
29.240.30
CCS
发布
20191205
实施
20191205

随着特高压电网相继投入运行,风电、太阳能等可再生、清洁能源的大量接入,及区域电网互联互通的实现,电网控制和运行进入了大电网时代。大电网运行对电力调度和负荷控制提出了更高的要求,现有的安稳系统、低频低压减载装置和事故拉闸限电手段可力保主网稳定运行,但局部地区用户受大面积停电的影响难以避免。 网荷互动终端装置是面向用户的负荷采集和负荷快速控制终端,应用先进通信和控制技术,与安全稳定控制系统和电力负荷快速响应主站紧密配合,通过对电力负荷“友好互动”的控制方式和精准负荷控制手段解决电网频率跌落、潮流越限、联络线超用和系统备用不足等诸多问题,确保电网可靠供电,显著降低大电网扰动的影响,可实现电源、电网、用户负荷友好互动,是电力系统精益化管理的重要手段之一。 本标准用于规范网荷互动终端的技术要求、功能规范、试验方法和检验规范等,为开展网荷互动终端设备的生产、使用、检测、验收提供典型标准及参考。编制目的为保障网荷互动终端设备技术和功能的规范性,以及终端制造厂家设备的一致性,保障终端的产品质量。

Technical specification for grid-load interactive terminal

ICS
29.240.30
CCS
D4420
发布
2019-08-21
实施
2019-09-02

Specifications for electrical safety testing and inspection of high-voltage switchgear in use in metal and non-metal mines

ICS
29.240.30
CCS
K43
发布
2019-08-12
实施
2020-02-01

Electrical test specifications for high-voltage switchgear in use in coal mines

ICS
29.240.30
CCS
K43
发布
2019-06-04
实施
2019-10-01

1 Scope 1.1 These requirements apply to control panels, control units, and other various electrical circuits employed within a control circuit device intended for support functions, maintain operation and limiting safety control features for use in a Stationary Engine Driven Assembly or similar power production equipment control applications. 1.2 These requirements cover controls operating at 600 Volts a. c. or d. c maximum with sensing and measurement circuits without the use of isolation devices and 36 kV a.c. or d.c. maximum with the use of isolation devices. 1.3 These requirements apply only to electrically operated control equipment. 1.4 These requirements apply to equipment intended to be operated and installed by qualified personnel in the field. 1.5 These requirements apply to control equipment used in or with movable engine driven assemblies that are otherwise constructed the same as stationary engine driven assemblies. 1.6 These requirements do not cover: a) Distribution equipment which sole function is the automatic or nonautomatic transferring of one or more load conductor connections from one power source to another. In Canada the Standard for Transfer Switch Equipment is CSA C22.2 No. 178.1. In the United States it is the Standard for Transfer Switch Equipment, UL 1008. b) Devices in the output power circuit, but would apply to pilot devices that monitor or control switching devices that control loads in power circuits. c) Controls for the propulsion engine of a vehicle. d) Independent equipment that does not perform any control function of an engine driven assembly or similar power production equipment control applications. e) Equipment or devices for use in or connected to hazardous (Classified) locations. f) Industrial Control Equipment for general use. In Canada the Standard for Industrial Control Equipment is CSA C22.2 No. 14. In the United States it is the Standard for Industrial Control Equipment, UL 508. g) General Use Industrial Control Panels and Industrial Control Panel Assemblies other than power production. In Canada the Standard for Industrial Control Panels and Assemblies is CSA C22.2 No. 286. In the United States it is the Standard for Industrial Control Panels, UL 508A. h) Equipment or devices for use in mobile applications.

Standard for Controllers for Use in Power Production

ICS
29.240.30
CCS
发布
2019-05-31
实施

本标准主要针对江苏电网源网荷紧急切负荷安全稳定控制系统,重点制定了系统构成及功能,一般技术要求等,本标准由6章构成,各章主要内容如下:  第1章为范围。 第2章为规范性引用文件。 第3章为术语和定义,列出了源网荷紧急切负荷安全稳定控制系统所涉及的主要专业术语及其解释。 第4章为总则,规定了源网荷紧急切负荷安全稳定控制系统的总体目标和基本原则。 第5章为系统构成及功能,对控制中心站、控制主站、控制子站、用户就近变电站、负控终端、通信通道等内容进行了明确和规范。 第6章为一般技术要求,对基本判据、压板原则、功能要求、输入输出等内容进行了明确和规范。

Technical specification for security and stability control system of source-grid-load emergency load shedding

ICS
29.240.30
CCS
D4420
发布
2018-10-01
实施
2018-10-12

Technical Guidelines for Automatic Voltage Control Test

ICS
29.240.30
CCS
F24
发布
2018-06-06
实施
2018-10-01