This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this document is to detail a standard test method to assess the effectiveness of the contact retaining system to withstand axial loads likely to be encountered during normal use. The contact retaining system may retain the contact in an insert or directly into a housing.

Connectors for electronic equipment - Tests and measurements - Part 15-1: Connector tests (mechanical) - Test 15a: Contact retention in insert

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electomechanical components within the scope of technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to determine the holding capacity of grounding contact springs by means of gauges.

Connectors for electronic equipment - Tests and measurements - Part 16-9: Mechanical tests on contacts and terminations - Test 16i: Grounding contact spring holding force

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method for measuring the resistance between component housings (shells) which are intended to provide electrical continuity when mated. This test is not intended to verify shielding against magnetic or r.f. interference.

Connectors for electronic equipment - Tests and measurements - Part 2-6: Electrical continuity and contact resistance tests - Test 2f: Housing (shell) electrical continuity

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512 is applicable to electrical connectors, sockets, cable assemblies or interconnection systems. This standard describes a frequency and a time domain method to measure attenuation/ insertion loss as a function of frequency. NOTE “Attenuation” is referenced throughout the document. Test professionals must use the appropriate term (attenuation or insertion loss) when summarizing and reporting the test measurements according to the type of specimen and transmission line being measured.

Connectors for electronic equipment - Tests and measurements - Part 25-2: Test 25b - Attenuation (insertion loss)

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512 defines two test methods for evaluating the performance of a connector in a transmission line by measuring the reflections produced by it in the time domain. In these methods, the connector under test is treated as a discontinuity in a transmission line with a controlled characteristic impedance. Test method A uses precision coaxial and semi-rigid coaxial cables to connect the connector under test and the test equipment. This method is suitable for many connector or cableassembly geometries. Test method B uses precision test boards, precision coaxial cables and semi-rigid coaxial cables to connect the connector under test and the test equipment. This method is suitable for printed board connectors.

Connectors for electronic equipment - Tests and measurements - Part 23-4: Screening and filtering tests - Test 23d: Transmission line reflections in the time domain

ICS
31.220.10
CCS
发布
2015-09-03
实施

This International Standard applies to the transfer of video signals between two pieces of equipment in an NTSC, PAL or SECAM high-resolution colour video system, in the form of a Y-signal, consisting of luminance + blanking + sync, and a C-signal, the same as the modulated chrominance signal of the composite video signal. It specifies the signal levels and impedances at the interface and the type of connector to be used.

Audio, video and audiovisual systems - Interconnections and matching values - Part 5: Y/C connector for video systems - Electrical matching values and description of the connector

ICS
31.220.10
CCS
发布
2015-09-03
实施

1.1 Scope and object This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method to assess the ability of components to withstand specified severities of shock.

Connectors for electronic equipment - Tests and measurements - Part 6-3: Dynamic stress tests - Test 6c: Shock

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to detail a standard test method to assess the ability of a component to carry its specified current, at room temperature, without exceeding a specified temperature rise.

Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise

ICS
31.220.10
CCS
发布
2015-09-03
实施

This Recommendation covers a range of rectangular multipole connectors with blade contacts, with either solder type terminations or solderless terminations of the wrap type.

Connectors for frequencies below 3 MHz - Part 6: Rectangular miniature multipole connectors with blade contacts

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method to determine the variation of contact resistance of electromechanical components under specified dynamic conditions. This test should be carried out only on components the contact resistance of which is measured by test 2a.

Connectors for electronic equipment - Tests and measurements - Part 2-3: Electrical continuity and contact resistance tests - Test 2c: Contact resistance variation

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing connectors. It may also be used for similar devices when specified in a detail specification. It is particularly, but not exclusively, suitable for connectors with removable contacts. The object of this document is to detail a standard test method to assess the effectiveness of the interfacial sealing of a connector against ingress of water by exposure to low pressure whilst immersed in a salt solution. It is intended to assess the effectiveness of the interfacial sealing means of connectors. Further, if any wires or contacts are not fitted, it assesses the sealing of one cavity of a connector from another.

Connectors for electronic equipment - Tests and measurements - Part 14-6: Sealing tests - Test 14f: Interfacial sealing

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512-23 defines a test method which is intended to assess the screening effectiveness of screened non-circular multi-pole, electrically short, connectors by the measurement of the effective (surface) transfer impedance ZTE expressed in Ω, using a network analyzer, for frequencies up to 1 GHz. It is based on the line injection test method according IEC 61196-1 with a specific type of injection wire, which is adapted to the shapes of connectors. Due to the specific test set-up used in the method described hereinafter the connector screen itself is not verified, but the combination of two connectors (male and female) together, i.e. the test results include the effectiveness of the screens of the two connectors and the joint between the connectors and the joints of the cable to the connector.

Connectors for electronic equipment - Tests and measurements - Part 23-7: Screening and filtering tests - Test 23g: Effective transfer impedance of connectors

ICS
31.220.10
CCS
发布
2015-09-03
实施

1.1 Scope and object This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method to assess the ability of components to withstand specified severities of acceleration.

Connectors for electronic equipment - Tests and measurements - Part 6-1: Dynamic stress tests - Test 6a: Acceleration, steady state

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electomechanical components within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to determine ability of a component to resist forces that might strip a wrapped connection from its post along the axis of the post. Such wrapped connections are described in IEC 60352-1. NOTE This test is considered as destructive to specimens used.

Connectors for electronic equipment - Tests and measurements - Part 16-11: Mechanical tests on contacts and terminations - Test 16k: Stripping force, solderless wrapped connections

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this test procedure is to detail a standard test method to assess the capability of polarizing and or keying of connectors to allow intended mating and prevent unintended mating.

Connectors for electronic equipment - Tests and measurements - Part 13-5: Mechanical operation tests - Test 13e: Polarizing and keying method

ICS
31.220.10
CCS
发布
2015-09-03
实施

1.1 Scope and object This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method to assess the ability of components to withstand specified severities of bump.

Connectors for electronic equipment - Tests and measurements - Part 6-2: Dynamic stress tests - Test 6b: Bump

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to determine if a wrapped connection has been made without damaging the wrapping wire. Such wrapped connections are described in IEC 60352-1. NOTE This test is regarded as destructive of all components used.

Connectors for electronic equipment - Tests and measurements - Part 16-13: Mechanical tests on contacts and terminations - Test 16m: Un-wrapping, solderless wrapped connections

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 61076 describes M12 circular connectors typically used for industrial process measurement and control. These connectors consist of fixed and free connectors either rewireable or non-rewireable, with screw-locking. The connectors with glass to metal seal are fixed connectors only which consist of fixed glass to metal sealed styles with rewireable male contacts and are intermateable with corresponding free connectors according to this International Standard. Male connectors have round contacts ∅ 0,6 mm, ∅ 0,76 mm, ∅ 0,8 mm and ∅ 1,0 mm. The different codings prevent the mating of these coded male or female connectors to any other interfaces and cross-mating between the different codings. NOTE M12 is the dimension of the thread of the screw-locking mechanism of these circular connectors.

Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking

ICS
31.220.10
CCS
发布
2015-09-03
实施

1.1 Scope and object This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method to assess the ability of components to be stored and/or to function in a specified manner under conditions of high relative humidity.

Connectors for electronic equipment - Tests and measurements - Part 11-3: Climatic tests - Test 11c: Damp heat, steady state

ICS
31.220.10
CCS
发布
2015-09-03
实施

This part of IEC 60512, when required by the detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method to assess the ability of components to be stored and/or to function in a specified manner under specified conditions of dry heat.

Connectors for electronic equipment - Tests and measurements - Part 11-9: Climatic tests - Test 11i: Dry heat

ICS
31.220.10
CCS
发布
2015-09-03
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号