This European Standard defines the technical specifications and requirements for the definition of the cooling capacity of pre-fabricated ceiling mounted radiant panels according to the specifications of EN 14037-1:2016, 3.3.1. The test according to this standard requires the measurement of the thermal output according to EN 14037-2:2016 of the model.
Free hanging heating and cooling surfaces for water with a temperature below 120��- Part 4: Pre-fabricated ceiling mounted radiant panels - Test method for cooling capacity
This European Standard describes the procedure to determine the rated thermal output (D) and the mean surface temperature (trp) of pre-fabricated ceiling mounted radiant panels. Pre-fabricated ceiling mounted radiant panels exchange heat mainly by radiation. The test methods for determining the thermal output of pre-fabricated ceiling mounted radiant panels, as described in EN 14037-2:2016, give reliable results for comparing different products, but these results understate the output obtained under real operating conditions.
Free hanging heating and cooling surfaces for water with a temperature below 120��- Part 3: Prefabricated ceiling mounted radiant panels for space heating - Rating method and evaluation of radiant thermal output
Periodic Inspection and Evaluation of Welded Insulated Gas Cylinders
This European Standard applies to mechanical cooling devices with air circulation heat exchangers with or without heating device. The mechanical cooling devices are intended to be used with insulated transport equipment. They include a drive or a means of force transmission and are provided with all the components necessary for the controlled thermal transport system. The mechanical cooling devices can be powered with independent engine and/or vehicle engine and/or any other source of energy. This standard specifies the testing methodologies.
Testing methodologies of refrigerating devices for insulated means of transport - Part 1: Mechanical cooling device with forced air circulation evaporator with or without heating device
本标准规定了冷却塔风机用水轮机的产品型号、主要技术参数及性能、要求、试验方法、检验规则、标志、使用说明书、包装、运输及贮存。 本标准适用于处理水量500m³/h~5500m³/h(15kW~200kW)的冷却塔风机用水轮机。
Cooling Tower Fan Water Turbine
Economical operation management of cooling tower and the system
この規格は,パッケージエアコンディショナ,冷凍機器などで温まった冷却水を外気との直接接触操作によって冷却し循環使用するための装置である強制通風式クーリングタワーのうち,設計標準冷却能力が233 kW以下のものの大気圧における性能試験方法について規定する。
Performance tests of mechanical draft cooling tower
This European Standard refers to gas filters and combined filters for use as components in unassisted respiratory protective devices. Filters for use against CO are excluded from this standard. Laboratory tests are included for the assessment of compliance with the requirements. Some filters complying with this standard can also be suitable for use with assisted respiratory protective devices and if so they need to be tested be tested and marked according to the appropriate European Standard.
Respiratory protective devices - Gas filter(s) and combined filter(s) - Requirements, testing, marking
This proposed revision of ASHRAE Standard 18 updates the 2006 edition to provide the rating information that was lost when ARI Standard 1010 was recently withdrawn. This information has been added in Table 2 of this standard. Minor editorial improvements have also been implemented. Standard 18 prescribes a method of testing for the cooling capacity and energy consumption of self-contained mechanically refrigerated drinking-water coolers.
Methods of Testing for Rating Drinking-Water Coolers with Self-Contained Mechanical Refrigeration
The activities above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http://assist.daps.dla.mil.
HEAT INTERCHANGER, REFRIGERANT-12
Standard 143 provides procedures for testing indirect evaporative cooling devices under laboratory conditions to obtain rating information. This proposed revision of the standard decreases the difference between the primary dry bulb and secondary temperatures from 25 to 20?F (14 to 11? C) to increase the times when testing can be accomplished with unconditioned air without a loss of testing accuracy. The draft also updates references and makes editorial corrections.
Methods of Testing for Rating Indirect Evaporative Coolers
This proposed revision of Standard 18 adds a method of test for energy consumption of self-contained, mechanically refrigerated drinking-water coolers and assumes that ARI will specify rating conditions for energy consumption in a future revision of Standard 1010.
Method of Testing for Rating Drinking-Water Coolers with Self-Contained Mechanical Refrigeration Systems
Provides uniform test methods for conducting and reporting thermal performance characteristics of wet mechanical draft, natural draft, wet-dry cooling towers, closed circuit evaporative (wet) coolers, and wet surface air-cooled steam condensers. This Code also provides directions and rules for conducting and reporting plume abatement of wet-dry cooling towers and water consumption of any cooling tower. This Code provides explicit test procedures to yield results of the highest levels of accuracy consistent with the best engineering knowledge and practice currently available. The purpose of this Code is to provide rules for monitoring thermal performance or for conducting acceptance tests on all of the cooling equipment referenced above. It provides rules for monitoring plume abatement and conducting plume-abatement acceptance tests on wet-dry cooling towers.
Atmospheric Water Cooling Equipment
この規格は,銅及び銅合金に対して腐食性のない冷媒を用いた,冷凍装置の銅管の接続に使用するフレア管継手(管端部のフレア加工を含む。),銅合金ろう付けソケット管継手及びろう付け管継手(以下,総合して管継手という。)について規定する。備考 この規格で用いる圧力は,ゲージ圧力をいう。
Flare type and brazing type fittings for refrigerants
This amendment forms a part of MS17241B dated 21 March 1975 and is approved for use by all Departments and Agencies of the Department of Defens
HEAT INTERCHANGER, REFRIGERANT-12
The purpose of ANSVAWWA B100 is to provide purchasers with a standard for the purchase and installation of granular filter material (filter material).
Granular Filter Material ANSI/AWWA B100-01
Flare type and brazing type fittings for refrigerants
The scope of this document is to define a practical method for determining the heat leak performance of cryogenic vessels.
Cryogenic vessels - Methods for performance evaluation of thermal isolation; German version EN 12213:1998
This notice should be filed in front of MS16993B, dated 22 June 1978.
PLUGS, FUSIBLE, REFRIGERANT-12
This notice should be filed in front of MIL-R-22928B, dated 29 March 1974.
RECEIVERS, LIQUID REFRIGERANT-12