K09 卫生、安全、劳动保护 标准查询与下载



共找到 460 条与 卫生、安全、劳动保护 相关的标准,共 31

Covers safety clearances between live parts and objects for rated voltages up to and including 145 kV. The clearances stipulated in this code of practice provide a measure of safety to persons in the vicinity of live parts. Does not cover distances maint

Code of practice for clearances for electrical systems with rated voltages up to and including 145 kV, for the safety of persons

ICS
29.240.20
CCS
K09
发布
2005-11-17
实施

이 규격은 공칭 주파수 500 Hz 이하의 공칭 전압 교류 1 kV, 직류 1.5 kV 이

Live working-Voltage detectors-Part 3:Two-pole low-voltage type

ICS
29.260.99
CCS
K09
发布
2005-07-29
实施
2005-07-29

이 규격은 전기 설비의 활선 작업에서 사용하는 기구 및 장치의 품질을 보증하기 위한 것으로

Live working-Guidelines for quality assurance plans

ICS
29.260.99;13.260;29.240.20
CCS
K09
发布
2005-07-29
实施
2005-07-29

Specifies the characteristics of access cards intended to be used in access control systems.

Electrical security systems Part 2-6: Access control systems: Access cards

ICS
13.310;35.220.99
CCS
K09
发布
2005-06-24
实施

Specifies the characteristics of barriers intended to be used in access control systems.

Electrical security systems Part 2.7: Access control systems: Barriers

ICS
13.310
CCS
K09
发布
2005-06-24
实施

Summarizes the basic parameters for lightning and their variability insofar as they apply to human beings and livestock. It indicates the possible direct and indirect interactions of strikes with bodies of living beings and describes the resulting effects caused by lightning currents. It is intended to show the differences between effects on human beings and livestock due to lightning strokes and those effects of electric shocks derived from electrical systems.

Effects of current on human beings and livestock Part 4: Effects of lightning strokes on human beings and livestock

ICS
13.260
CCS
K09
发布
2005-06-10
实施

Specifies the characteristics of reader controllers intended to be used in access control systems.

Electrical security systems Part 2.4: Access control systems: Reader controllers

ICS
13.310;35.160
CCS
K09
发布
2005-06-10
实施

Specifies the characteristics of biometric readers intended to be used in access control systems.

Electrical security systems Part 2-5: Access control systems: Biometric readers

ICS
13.310;35.180
CCS
K09
发布
2005-06-10
实施

Specifies the characteristics of card readers using the following technologies: wiegand: magnetic, infra-red: optic sensor, magnetic: magnetic sensor for magnetic spot cards or magnetic stripe cards, proximity: magnetic or radio frequency field se

Electrical security systems Part 2-3: Access control systems: Card readers

ICS
13.310;35.180
CCS
K09
发布
2005-06-03
实施

Specifies the characteristics of central processors for use as part of access control systems.

Electrical security systems Part 2-2: Access control systems: Central processor

ICS
13.310;35.160
CCS
K09
发布
2005-03-18
实施

Specifies the test method for the determination of the electrical resistance of floors

Electrical resistance of floors

ICS
17.220.20;91.060.30
CCS
K09
发布
2005-03-04
实施

Specifies the general characteristics of access control systems.

Electrical security systems Part 2-1: Access control systems: General characteristics

ICS
13.310;35.160
CCS
K09
发布
2005-01-14
实施

MIL-D-51048F remains inactive for new design, however, the document is valid for use.

DECONTAMINATING APPARATUS, PORTABLE, DS2, 1-1/2 QUART, M11

ICS
13.120
CCS
K09
发布
2004-08-03
实施

MIL-D-51091J remains inactive for new design, however, the document is valid for use.

DECONTAMINATING APPARATUS, POWER DRIVEN, SKID-MOUNTED, MULTIPURPOSE, NONINTEGRAL, 500 GALLON, M12A1

ICS
13.120
CCS
K09
发布
2004-08-03
实施

This part of IEC 61496 specifies general requirements for the design, construction and testing of non-contact electro-sensitive protective equipment (ESPE) designed specifically to detect persons as part of a safety related system. Special attention is directed to functional and design requirements that ensure an appropriate safety-related performance is achieved. An ESPE may include optional safety-related functions, the requirements for which are given in Annex A. The particular requirements for specific types of sensing function are given in other parts of this standard. This standard does not specify the dimensions or configuration of the detection zone and its disposition in relation to hazards in any particular application, nor what constitutes a hazardous state of any machine. It is restricted to the functioning of the ESPE and how it interfaces with the machine. While a data interface can be used to control optional safety-related ESPE functions (Annex A), this standard does not provide specific requirements. Requirements for these safety-related functions can be determined by consulting other standards (for example, IEC 61508, IEC/TS 62046, IEC 62061, and ISO13849-1). This standard may be relevant to applications other than those for the protection of persons, for example for the protection of machinery or products from mechanical damage. In those applications, different requirements can be necessary, for example when the materials that have to be recognized by the sensing function have different properties from those of persons. This standard does not deal with electromagnetic compatibility (EMC) emission requirements.

Safety of machinery - Electro-sensitive Protective equipment - Part 1: General requirements and tests

ICS
13.110
CCS
K09
发布
2004-06-01
实施
2004-06-01

This part of IEC 61496 specifies general requirements for the design, construction and testing of non-contact electro-sensitive protective equipment (ESPE) designed specifically to detect persons as part of a safety related system. Special attention is directed to functional and design requirements that ensure an appropriate safety-related performance is achieved. An ESPE may include optional safety-related functions, the requirements for which are given in Annex A. The particular requirements for specific types of sensing function are given in other parts of this standard. This standard does not specify the dimensions or configuration of the detection zone and its disposition in relation to hazards in any particular application, nor what constitutes a hazardous state of any machine. It is restricted to the functioning of the ESPE and how it interfaces with the machine. This standard may be relevant to applications other than those for the protection of persons, for example for the protection of machinery or products from mechanical damage. In those applications, different requirements can be necessary, for example when the materials that have to be recognized by the sensing function have different properties from those of persons. This standard does not deal with electromagnetic compatibility (EMC) emission requirements.

Safety of machinery - Electro-sensitive protective equipment - General requirements and tests

ICS
13.110
CCS
K09
发布
2004-06-01
实施
2004-06-01

MIL-PRF-62048C, dated 12 April 1996, has been reviewed and determined to be valid for use in acquisition

AIR CLEANERS, AUTOMOTIVE: HEAVY DUTY, DRY-TYPE (FOR INTERNAL COMBUSTION ENGINES) (METRIC)

ICS
13.120
CCS
K09
发布
2004-04-15
实施

MIL-DTL-62337B, dated 29 April 1999, has been reviewed and determined to be valid for use in acquisition

AIR CLEANER ASSEMBLY

ICS
13.120
CCS
K09
发布
2004-04-12
实施

This commercial item description covers brown kraft paper used for general wrapping applications.

PURIFIER, AIR, M2A2 [Use In Lieu Of: ARMY MIL-P-0051070 F REINST NOTICE 3 CONT. DIST.]

ICS
13.120
CCS
K09
发布
2003-05-06
实施

Is applicable to equipment designed and intended to be connected directly to a telecommunication netword, regardless of the source of power. Is intended for the enhancement of product safetey standards so as to cover hazards associated only with connection of equipment to a telecommunication network.

Safety of equipment electrically connected to a telecommunication network

ICS
33.020;35.020
CCS
K09
发布
2003-03-14
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved