共找到 919 条与 防爆电器 相关的标准,共 62 页
UL Standard for Safety Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I@ II@ and III@ Division 1@ Hazardous (Classified) Locations (Eighth Edition; Reprint with Revisions Through and Including October 16@ 2015)
This part of IEC 60079 specifies the requirements for the design, construction, testing and marking of electrical equipment and Ex Components with type of protection increased safety "e" intended for use in explosive gas atmospheres.
Explosive atmospheres - Part 7: Equipment protection by increased safety "e" (IEC 60079-7:2015/A1:2017); German version EN IEC 60079-7:2015/A1:2018
This part of IEC 60079 gives the specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components with the type of protection encapsulation "m" intended for use in explosive gas atmospheres or explosive dust atmospheres. This amendment is intended to be an alternative for the dielectric strength test according to 9.2.
Explosive atmospheres - Part 18: Equipment protection by encapsulation "m" (IEC 60079-18:2014/A1:2017); German version EN 60079-18:2015/A1:2017
This part of IEC 60079 gives requirements for the design, construction, assessment, verification and marking of rooms.
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" (IEC 60079-13:2017); German version EN 60079-13:2017
Explosive atmospheres. Electrical resistance trace heating. Application guide for design, installation and maintenance
Explosive atmospheres - Part 18 : Equipment protection by encapsulation "m"
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
Explosive atmospheres - Part 0: Equipment - General requirements
Explosive atmospheres. Electrical resistance trace heating. General and testing requirements
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
Explosive atmospheres - Part 32-1: Electrostatic hazards, guidance
The motor has not been type-tested for this duty as a unit in association with the converter. In this case, means (or equipment) for direct temperature control by embedded temperature sensors specified in the motor documentation or other effective measures for limiting the surface temperature of the motor housing shall be provided. The effectiveness of the temperature control shall take into consideration power, speed range, torque and frequency for the duty required and shall be verified and documented. The action of the protective device shall cause the motor to be electrically disconnected.
Explosive Atmospheres - Part 14: Electrical installations design, selection and erection; Interpretation Sheet 1
Design of fans working in potentially explosive atmospheres
Explosive atmospheres. Equipment and components in explosive atmospheres in underground mines
Explosive atmospheres - Part 38: Equipment and components in explosive atmospheres in underground mines (ISO/IEC 80079-38:2016)
Explosive atmospheres - Part 7: Equipment protection by increased safety "e" (IEC 60079-7:2015); German version EN 60079-7:2015
Erection of electrical installations in underground mines
Explosive atmospheres - Part 28 : protection of equipment and transmission systems using optical radiation
Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" (IEC 60079-6:2015); German version EN 60079-6:2015
Explosive atmospheres. Non-electrical equipment for explosive atmospheres. Basic method and requirements
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved