Information is provided to specifiers and users of surge protective devices (SPDs) about the application considerations associated with power distribution systems within North America. Applies to SPDs to be connected to the load side of the service entrance main over current protective device of 50 Hz or 60 Hz ac power circuits rated at 100-1000 Vrms.

Guide for the Application of Surge Protective Devices for Low Voltage (1000 Volts or Less) AC Power Circuits

ICS
29.240.10;29.240.30
CCS
K45
发布
2007-09-19
实施

General technical specifications for integrated protection unit of 380V~1.2kV digital electromotors.

ICS
29.120.50
CCS
K45
发布
2007-07-01
实施
2007-07-01

General technical specifications for integrated protection unit of 3V~10kV digital electromotors.

ICS
29.120.50
CCS
K45
发布
2007-07-01
实施
2007-07-01

Describes field test methods that assure that current transformers are connected properly, are of marked ratio and polarity, and are in a condition to perform as designed both initially and after having been in service for a period of time.

Field Testing of Relaying Current Transformers

ICS
29.180
CCS
K45
发布
2007-05-02
实施

The purpose of this PAS is to provide a guide for the design of electrode stations for HVDC links intended for ground return. This design guide was prepared by the CIGR? Working Group 14.21: HVDC Ground Electrode Design during the period 1995-1998. It is not the purpose of this report to provide detailed instructions on how to work out an HVDC link from the initial idea to final decisions on sites, ratings, constructional principles for converter stations and for connecting lines/cables. In the often hectic planning phase of a new link, the main emphasis will be concentrated on converter stations and the line/cable, while less attention is paid to a simultaneous evaluation of possible current return principles.

General guidelines for the design of ground electrodes for high-voltage direct current (HVDC) links (NPPAS)

ICS
29.240.99
CCS
K45
发布
2007-05
实施

Technical Specification for Secondary System Security and Protection of Hubei Power

ICS
29.240.30
CCS
K45
发布
2007-04-05
实施
2007-03-01

本标准规定了电力系统二次设备(如:继电器、保护及自动控制装置等)用电气连接件的使用环境条件、技术要求、试验方法、检验规则、标志、包装、贮存、运输、供货的成套性和质量保证。 本标准适用于电力系统二次设备用通用电气连接件,如:接线端子、连接器等(以下简称连接件),作为其生产和验收的依据。 本标准不适用于电力系统二次设备PCB用连接件。

General specifications for electric connector of secondary equipment of power system

ICS
29.240.01
CCS
K45
发布
2007-01-25
实施
2007-07-01

This Standards Publication applies to ground rod electrodes and ground rod electrode couplings that function in accordance with the National Electrical Code? (NFPA 70-2005) and/or the National Electrical Safety Code (ANSI C2-2002). Included are materials, construction, and performance of copper bonded ground rod electrodes, zinc-coated ground rod electrodes, and stainless steel clad ground rod electrodes. This standards publication also includes information for electrode products that have been successfully used for many years but are not defined within the National Electrical Code or the National Electrical Safety Code. The items described in this Standards Publication are defined in Section 1.

Ground Rods and Ground Rod Couplings

ICS
29.120.50
CCS
K45
发布
2007
实施

This technical report provides an overview of protection availability provided by residual current-operated protective devices (RCDs) complying with IEC standards for household and similar uses. It highlights the main parameters influencing protection reliability and provides information on how to install and operate RCDs in relationship to their environmental conditions after installation. This guide gives general information concerning availability of the protection within the fixed installation and how to keep a high level of availability of protection during use (installation and maintenance). It has been drafted for the benefit of IEC technical committees, installers, inspectors and users. NOTE 1 The term RCD is a generic term applied to a family of products which open automatically in response to a residual current at or exceeding the RCD’s rated residual operating current, IΔn. This generic term is often applied to the following. RCCB - Residual Current Circuit Breaker without overcurrent protection RCBO - Residual Current Breaker with Overcurrent protection SRCD - Socket outlet Residual Current Device PRCD - Portable Residual Current Device A RCCB differs from a RCBO in that the RCBO will additionally respond to overcurrent conditions whereas the RCCB will not respond to such conditions. NOTE 2 PRCDs are not considered to be part of the fixed installation, and are not covered by this guide.

Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use

ICS
29.120.50
CCS
K45
发布
2006-12
实施

This part of IEC 61643 describes the principles for selection, operation, location and co-ordination of SPDs to be connected to 50 Hz to 60 Hz a.c. power circuits and equipment rated up to 1 000 V r.m.s.. NOTE 1 This technical specification deals only with SPDs and not with SPDs components integrated inside equipment.

Low-voltage surge protective devices - Surge protective devices connected to low-voltage power systems - Selection and application principles

ICS
29.240.10
CCS
K45
发布
2006-10-31
实施
2006-10-31

This part of IEC 61643 describes the principles for selection, operation, location and co-ordination of SPDs to be connected to 50 Hz to 60 Hz a.c. power circuits and equipment rated up to 1 000 V r.m.s.. NOTE 1 This technical specification deals only with SPDs and not with SPDs components integrated inside equipment.

Low-voltage surge protective devices — Part 12: Surge protective devices connected to low-voltage power systems — Selection and application principles

ICS
29.240;29.240.10
CCS
K45
发布
2006-10-31
实施

本标准规定了小功率电流电压变换器的技术要求、试验方法、检验规则、标志、包装、运输、贮存、供货的成套性及质量保证等。 本标准适用于电力系统继电保护及自动化装置中使用的小功率电流电压变换器(以下简称变换器)。 本标准适用于感应式的电流一电流、电流一电压及电压一电压变换器,其他类型的小功率电流电压变换器可参考采用。

General specification for current & voltage transducer with small power

ICS
29.240.99
CCS
K45
发布
2006-10-14
实施
2007-04-01

This International Standard applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A, intended principally for protection against shock-hazard. These devices are intended to protect persons against indirect contact, the exposed conductive parts of the installation being connected to an appropriate earth electrode. They may be used to provide protection against fire hazards due to a persistent earth fault current, without the operation of the overcurrent protective device. RCCBs having a rated residual operating current not exceeding 30 mA are also used as a means for additional protection in case of failure of the protective means against electric shock. This standard applies to devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. NOTE 1 The requirements for RCCBs are in line with the general requirements of IEC 60755. RCCBs are essentially intended to be operated by uninstructed persons and designed not to require maintenance. They may be submitted for certification purposes. NOTE 2 Installation and application rules of RCCBs are given in IEC 60364. They are intended for use in an environment with pollution degree 2. They are suitable for isolation. Special precautions (e.g. lightning arresters) may be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines) (see IEC 60364-4-443). RCCBs of the general type are resistant to unwanted tripping including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCCBs of the S type are considered to be sufficient proof against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. NOTE 3 Surge arresters installed downstream of the general type of RCCBs and connected in common mode may cause unwanted tripping. NOTE 4 For RCCBs having a degree of protection higher than IP20 special constructions may be required. Particular requirements are necessary for – Residual current operated circuit-breakers with integral overcurrent protection (see IEC 61009); – RCCBs incorporated in or intended only for association with plugs and socket-outlets or with appliance couplers for household or similar general purposes. NOTE 5 For the time being, for RCCBs incorporated in, or intended only for socket-outlets or plugs, the requirements of this standard in conjunction with the requirements of IEC 60884-1 may be used as far as applicable. The requirements of this standard apply for normal environmental conditions (see 7.1). Additional requirements may be necessary for RCCBs used in locations having severe environmental conditions. RCCBs including batteries are not covered by this standard.

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

ICS
29.120.50
CCS
K45
发布
2006-06
实施

This International Standard applies to residual current operated circuit-breakers with integral overcurrent protection functionally independent of, or functionally dependent on, line voltage for household and similar uses (hereafter referred to as RCBOs), for rated voltages not exceeding 440 V a.c., rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. These devices are intended to protect people against indirect contact, the exposed conductive parts of the installation being connected to an appropriate earth electrode and to protect against overcurrents the wiring installations of buildings and similar applications. They may be used to provide protection against fire hazards due to a persistent earth fault current, without the operation of the overcurrent protective device. RCBOs having a rated residual operating current not exceeding 30 mA are also used as a means for additional protection in the case of failure of the protective means against electric shock. This standard applies to devices performing simultaneously the function of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value, and also of performing the function of making, carrying and breaking overcurrents under specified conditions. The content of the present standard related to protection against overcurrents is based on IEC 60898. RCBOs of the general type are resistant to unwanted tripping, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCBOs of the S type are considered to be sufficiently proof against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. RCBOs are suitable for isolation. Special precautions (e.g. lightning arresters) may be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines) (see IEC 60364-4-443). This standard also applies to RCBOs obtained by the assembly of an adaptable residual current device with a circuit-breaker. The mechanical assembly shall be effected in the factory by the manufacturer, or on site, in which case the requirements of annex G shall apply. It also applies to RCBOs having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. Supplementary requirements may be necessary for RCBOs of the plug-in type. Particular requirements are necessary for RCBOs incorporated in or intended only for association with plugs and socket-outlets or with appliance couplers for household and similar general purposes. This standard does not apply to: – RCBOs intended to protect motors, – RCBOs the current setting of which is adjustable by means accessible to the user in normal service. The requirements of this standard apply for normal environmental conditions (see 7.1). Additional requirements may be necessary for RCBOs used in locations having severe environmental conditions. RCBOs including batteries are not covered by this standard. A guide for the co-ordination of RCBOs with fuses is given in annex F.

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

ICS
29.120.50
CCS
K45
发布
2006-06
实施

This TS 61643-22 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. This TS also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure.

Low-voltage surge protective devices — Part 22: Surge protective devices connected to telecommunications and signalling networks — Selection and application principles

ICS
29.240;29.240.10
CCS
K45
发布
2006-05-31
实施

本标准规定了电力系统继电保护和电网安全自动装置及其二次回路接线(以下简称装置)检验的周期、内容及要求。 本标准适用于电网企业、并网运行发电企业及用户负责继电保护运行维护和管理的单位。有关规划设计、研究制造、安装高度单位及部门均应遵守本标准。

Testing Regulations on Protection and Stability Control Equipment

ICS
29.240.01
CCS
K45
发布
2006-05-06
实施
2006-10-01

本标准规定了湖北电网继电器保护装置技术原则、选型管理规定及配置原则。适用于湖北电力调度中心管辖范围内的系统。

Technical Principle and Configuration Specification for Relaying Protection of Hubei Power Grid

ICS
29.240.01
CCS
K45
发布
2005-12-31
实施
2006-03-01

本标准规定了湖北电网继电器保护及安全自动装置运行管理的机构、职责、验收、管理内容及要求。适用于湖北电力调度中心管辖范围内的系统。根据原水利电力部(82)水电生字第11号文件。结合湖北电网实际情况,对《湖北省电力工业局继电器保护及安全自动装置运行管理规程》进行了修订,形成本规范。

Operation and Management Specification for Relaying Protection,Security and Automatic Equipment of Hubei Power Grid

ICS
29.240.01
CCS
K45
发布
2005-12-31
实施
2006-03-01

Compiles a list of terms and definitions relative to IEC publications from IEC technical committee 37: Surge arresters and subcommittees 37A: Surge protective devices and 37B: Surge protective components, current at the date of this publication.

Surge arresters Part 7: Glossary of terms and definitions from IEC publications 60099-1, 60099-4, 60099-6, 61643-1, 61643-12, 61643-21, 61643-311, 61643-321, 61643-331 and 61643-341

ICS
01.040.29;29.240.10
CCS
K45
发布
2005-03-04
实施

Specifies requirements and tests for metal-oxide surge arresters with internal series gaps, with rated voltages 52kV and below. Applies to non-linear metal-oxide resistor type surge arresters with spark gaps designed to limit voltage surges on a.c. power

Surge arresters Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less

ICS
29.240.10
CCS
K45
发布
2005-02-18
实施