K47 输电线路器材 标准查询与下载



共找到 464 条与 输电线路器材 相关的标准,共 31

Grading ring,shielding ring, grading and shielding ring

ICS
29.240.99
CCS
K47
发布
2001-10-08
实施
2001-02-01

Covers safety requirements for service-entrance, feeder, and branch-circuit busways and associated fittings rated 600 volts or less and intended for use in accordance with ANSI/NFPA 70-1981, National Electrical Code. Metal-enclosed bus for connecting switch gear assemblies for use in prefabricated electric distribution systems is not covered. These revised pages involve requirements for: (1) grounding of exposed dead metal parts; (2) tightening torque for field wiring terminals; (3) use of 75 degree C wire; (4) increased ampacity for conductors; (7) markings; and (8) overcurrent protection for trolley devices.

Busways

ICS
29.120.10
CCS
K47
发布
2001-01-15
实施

Power piping

ICS
23.040.01
CCS
K47
发布
2001
实施

This standard is about Live working - Voltage detectors - Part 3: Two-pole low-voltage type; Corrigendum 1

Live working - Voltage detectors - Part 3: Two-pole low-voltage type

ICS
13.260
CCS
K47
发布
2000-12
实施

This is Technical Corrigendum 3 to IEC 61230-1993 (Live working - Portable equipment for earthing or earthing and short-circuiting)

Live working; portable equipment for earthing or earthing and short-circuiting

ICS
13.260
CCS
K47
发布
2000-12
实施

Powered winch technology specification

ICS
29.240.01
CCS
K47
发布
2000-11-03
实施
2001-01-01

Aerial devices for live working on live parts with voltages up to a.c. 1000 V and d.c. 1500 V

ICS
13.260
CCS
K47
发布
2000-11
实施
2000-11-01

This standard is Insulating poles (insulating sticks) and universal tool attachments (fittings) for live working; Corrigendum 1.

Insulating poles (insulating sticks) and universal tool attachments (fittings) for live working

ICS
13.260
CCS
K47
发布
2000-05
实施

This is Technical Corrigendum 1 to IEC 61243-3-1998 (Live working - Voltage detectors -Part 3: Two-pole low-voltage type )

Live working - Voltage detectors - Part 3: Two-pole low-voltage type

ICS
13.260
CCS
K47
发布
2000-05
实施

Hand tools for live working up to 1000 V a.c. and 1500 V d.c.; Amendment 1

ICS
13.260
CCS
K47
发布
2000-05
实施

This is Technical Corrigendum 2 to IEC 61235-1993 (Live working - Insulating hollow tubes for electrical purposes)

Live working; insulating hollow tubes for electrical purposes

ICS
13.260
CCS
K47
发布
2000-05
实施

This is Technical Corrigendum 2 to IEC 61230-1993 (Live working - Portable equipment for earthing or earthing and short-circuiting)

Live working; portable equipment for earthing or earthing and short-circuiting

ICS
13.260
CCS
K47
发布
2000-05
实施

This is Technical Corrigendum 1 to IEC 61236-1993 (Saddles, pole clamps (stick clamps) and accessories for live working)

Saddles, pole clamps (stick clamps) and accessories for live working

ICS
13.260
CCS
K47
发布
2000-05
实施

Methods of measurement of touch current and protective conductor current.

ICS
13.260
CCS
K47
发布
2000-04-01
实施
2000-04-05

This standard is Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c. Corrigendum 3

Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.; Corrigendum 3

ICS
13.260
CCS
K47
发布
2000-03
实施

This part of IEC 61243 is applicable to portable voltage detectors with or without a built-in power source to be used on electrical systems for voltages of 1 kV to 36 kV a.c., and frequencies from 15 Hz to 60 Hz. This part applies only to resistive voltage detectors used in contact with the part to be tested, as a single unit or as a separate device completed by an adaptable insulating pole covered in IEC 60855 or IEC 61235. Other types of voltage detectors are not covered by this part of standard. Capacitive voltage detectors are covered in IEC 61243-1. The upper voltage limit is in accordance with the tests described in this part of IEC 61243. Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see annex B). NOTE 1 Except when otherwise specified, all the voltages defined in this standard refer to phase-to-phase voltages of three-phase systems. Resistive detectors may be used in other than three-phase systems, but the applicable phase-to-phase or phase-to-earth (ground) voltage shall be used to determine the operating voltage. NOTE 2 Although this standard does not cover d.c. voltage detectors, some detectors may respond to d.c. voltage.

Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.

ICS
13.260
CCS
K47
发布
2000-03
实施

Bus-bar clamp

ICS
29.240.20
CCS
K47
发布
2000-02-24
实施
2000-07-01

Hydraulic compressor

ICS
29.240.01
CCS
K47
发布
2000-02-24
实施
2000-07-01

Countersunk head screws for bus-bar fitting

ICS
29.240.99
CCS
K47
发布
2000-02-24
实施
2000-07-01

Basic requirements,inspection specification and determination methods of conductor stringing sheave

ICS
29.240.99
CCS
K47
发布
2000-02-24
实施
2000-07-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved