共找到 464 条与 输电线路器材 相关的标准,共 31 页
This part of IEC 61249 gives requirements for properties of modified brominated epoxide woven E-glass reinforced laminate sheets of defined flammability (vertical burning test), copper-clad in thicknesses of 0,05 mm up to 3,2 mm. The flammability rating is acheived through the use of brominated fire retardants reacted as part of the epoxide polymeric structure. The glass transition temperature is defined as being between 150 ℃ and 190 ℃. Some property requirements may have several classes of performance. The class desired needs to be specified on the purchase order, otherwise the default class of material may be supplied.
Materials for interconnection structures - Sectional specification set for reinforced base materials, clad and unclad - Reinforced base materials clad and unclad - Modified brominated epoxide woven fibreglass reinforced laminated sheets of defined flammab
This part of IEC 60999 applies to screw-type and screwless-type clamping units for connecting devices, either as separate entities or as integral parts of equipment, for the connection of electrical copper conductors (complying with IEC 60228), rigid stranded and/or flexible, having a cross-section above 35 mm and up to and including 300 mm and equivalent AWG/kcmil sizes with a rated voltage not exceeding 1 000 V a.c. and a frequency up to and including 1 000 Hz and 1 500 V d.c. It applies to clamping units primarily suitable for connecting unprepared conductors. This standard does not apply to clamping units: - for connection by crimping or soldering; - for non-universal clamping units defined in 3.10.2 of IEC 60999-1.
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Particular requirements for clamping units for conductors above 35 mm
This standard is Live working - Gloves of insulating material; Corrigendum 1.
Live working - Gloves of insulating material
Technical requirements and testing method of helical fittings for OPGW
本标准规定了架空线路全介质自承式光缆用预绞式金具技术条件、试验方法、标志与包装等技术 本标准适用于架空线路全介质自承式光缆用预绞式悬垂线夹、耐张线夹、防振螺旋条等金具。
Technical requirements and testing method of helical fittings for ADSS
1.1 This specification covers high-strength, extra-high-strength, and utilities grades of concentric lay steel wire strand composed of three wires or seven wires with Class A, Class B, or Class C zinc-5% aluminum-mischmetal (Zn-5 Al-MM) alloy coatings specifically intended for use as overhead ground wires or static wires for electric power transmission lines. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
Standard Specification for Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Overhead Ground Wire Strand
1.1 This specification applies to the Clampstick type live line tools to ensure manufacturing processes and materials are compatible and no deterioration of components occur during the assembly process.1.2 This specification establishes the technical characteristics for clampsticks.1.3 This specification applies to clampsticks both hollow and foam-filled. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.The following safety hazards caveat pertains only to the test portions of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicable of regulatory limitations prior to use.1.5 The use, maintenance, and in-service testing of this equipment is beyond the scope of this specification.
Standard Specification for Clampstick Type Live Line Tools
Overhead electrical lines exceeding AC 45 kV - Part 2: Index of National Normative Aspects; German version EN 50341-2:2001
Live working - Ladders of insulating material (IEC 61478:2001); German version EN 61478:2001
This European Standard specifies requirements for aluminium lighting columns. It includes materials and conformity control. It applies to post top columns not exceeding 20 m height for post top lanterns and to columns with brackets not exceeding 18 m height for side entry lanterns.
Lighting columns - Part 6: Requirements for aluminium lighting columns; German version EN 40-6:2002
Live working - Terminology for tools, equipment and devices.
Cold forging hot dip galvanizing bolt and nut for tower and hardware of transmission lines
Manufacture quality specification for electric power fittings hot dip galvanized coatings on fabricated iron and steel articles
Manufacture quality specification for electric power fittings welding
Manufacture quality specification for electric power fittings Aluminium component
Manufacture quality specification for electric power fittings spheroidal graphite iron castings
Manufacture quality specification for electric power fittings stampings
Manufacture quality specification for electric power fittings forgings
Manufacture quality specification for electric power fittings malleable iron casting
This standard applies to overhead electric lines with rated voltages exceeding 45 kV AC and with rated frequencies below 100 Hz. This standard specifies the general requirements that shall be met for the design and construction of new overhead lines to ensure that the line is suitable for its purpose with regard to safety of persons, maintenance, operation and environmental considerations. This standard does not apply to : - overhead electric lines inside closed electrical areas as defined in HD 637; - catenary systems of electrified railways.
Overhead electrical lines exceeding AC 45 kV - General requirements - Common specifications