This part of IEC 60534 applies to the following control valves: - types: segmented ball and eccentric rotary control valves with or without flanges; - nominal sizes: DN20 up to and including DN400; NOTE 1 See ISO 7005 and ISO 6708. - designations: PN10, PN16, PN20, PN25, PN40, PN50, PN63, PN100 and PN110. NOTE 2 See ISO 7005 and ISO 7268. NOTE 3 Designations PN63 and PN100 are not included in ISO 7005. NOTE 4 Designations PN20, PN50 and PN110 are not included in European Standard EN 1092. NOTE 5 For the purposes of face-to-face dimensions, designation PN100 in EN 1092 corresponds to PN110. NOTE 6 For the purposes of face-to-face dimensions, the following correlations apply: - PN20 covers Classes 125 and 150 in the ANSI system; - PN50 covers Classes 250 and 300 in the ANSI system; - PN110 covers Class 600 in the ANSI system. Only raised face flanges are covered. Specifically excluded from this standard are all valves having welded or threaded end connections.

Industrial-process control valves. Dimensions. Face-to-face dimensions for rotary control valves except butterfly valves

ICS
23.060.01;23.060.40;25.040.40
CCS
N16
发布
2001-10-28
实施
2001-10-28

This part of IEC 60534 is intended to permit a variety of positioning devices, which respond to a rotary motion, to be mounted on the actuator of a control valve, either directly or by employing an intermediate mounting bracket. This standard is applicable where interchangeability between actuators and positioners is desired. a) The standardized mounting in this standard defines the interface between the positioner and a part of the actuator having a rotary movement proportional to the control valve travel. b) This standard also covers the direct connection between the positioner feedback and the shaft (or its axial extension) of a rotary control valve. In such cases, the feedback rotation is coincident with the valve angular travel. c) The standardized mounting applies to those rotary actuators in which the rotary part mentioned in item a) has a maximum travel of 90° Such a travel is coincident with the valve travel when a direct connection (see item b)) is performed. d) The standardized mounting is divided into two options. Figure 1 shows the basic design and defines the minimum requirements an actuator must fulfil to adapt most common positioners. The universal design in figure 2 offers more variations of positioner adaptation and positioner feedback connection. The positioner manufacturer should state which mounting design is required.

Industrial-process control valves. Mounting details for attachment of positioners to control valves. Positioner mounting on rotary actuators. Positioner mounting on rotary actuators

ICS
23.060.40
CCS
N16
发布
2001-06-15
实施
2001-06-15

本标准规定了符合HART协议的智能电动执行机构的产品分类、技术要求、试验方法、检验规则、标志、包装、贮存、运输等。 本标准适用于符合HART协议的智能电动执行机构。

General specification for intelligent electrical actuators with HART protocol

ICS
CCS
N16
发布
2001-04-09
实施
2001-09-01

Industrial-process control valves - Part 8 : noise considerations - Section 1 : laboratory measurement of noise generated by aerodynamic flow through control valves.

ICS
17.140.20;23.060.40
CCS
N16
发布
2001-01-01
实施
2001-01-05

This part of IEC 60534 establishes a theoretical method to predict the external sound-pressure level generated in a control valve and within adjacent pipe expanders by the flow of compressible fluids. This method considers only single-phase dry gases and vapours and is based on the perfect gas laws. This standard addresses only the noise generated by aerodynamic processes in valves and in the connected piping. It does not consider any noise generated by reflections, mechanical vibrations, unstable flow patterns and other unpredictable behaviour. It is assumed that the downstream piping is straight for a length of at least 2 m from the point where the noise measurement is made. This method is valid only for steel and steel alloy pipes (see equations (38) and (40) in 5.6). The method is applicable to the following single-stage valves: globe (straight pattern and angle pattern), butterfly, rotary plug (eccentric, spherical), ball, and valves with cage trims. Specifically excluded are the full bore ball valves where the product FPC exceeds 50 % of the rated flow coefficient. For limitations on special low noise trims not covered by this standard, see 6.5. When the Mach number in the valve outlet exceeds 0,3 for standard trim or 0,2 for low noise trim, the procedure in clause 7 is used. The Mach number limits in this standard are as follows:

Industrial-process control valves - Noise considerations - Control valve aerodynamic noise prediction method - Control valve aerodynamic noise prediction method

ICS
17.140.20;23.060.40
CCS
N16
发布
2000-12-15
实施
2000-12-15

This standard is Industrial-process control valves - Part 2-1: Flow capacity - Sizing equations for fluid flow under installed conditions; Corrigendum 1.

Industrial-process control valves - Part 2-1: Flow capacity - Sizing equations for fluid flow under installed conditions; Corrigendum 1

ICS
23.060.40
CCS
N16
发布
2000-02
实施

本标准规定了QFH型空气过滤减压器的基本参数及尺寸、技术要求、试验方法、检验规则、标志、包装、运输和贮存。 本标准适用于作为气动仪表辅助装置,对0.3MPa~1MPa的压缩空气进行净化和稳压,为气动仪表提供气源的QFH型空气过滤减压器。

QFH type air regulators with filter

ICS
CCS
N16
发布
1999-08-06
实施
2000-01-01

本标准规定了工业过程控制系统中执行器的术语和定义。 本标准适用于工业生产过程中控制工艺流体的控制阀、电磁阀、自力式调节阀等执行器产品的术语和定义。 本标准主要供制订执行器产品标准、编制文件、编写教材和书刊以及翻译文献等工作使用。

Terms for final controlling element

ICS
25.040.40
CCS
N16
发布
1999-08-06
实施
2000-01-01

本标准规定了工业过程测量和控制系统用电动执行机构的产品分类、技术要求、试验方法、检验规则等。 本标准适用于以电动机驱动的角行程、直行程、多转执行机构和伺服放大器、操作器等。

Electrical actuators for industrial - process measurement and control systems

ICS
25.040.40
CCS
N16
发布
1999-08-06
实施
2000-01-01

本标准规定了KF系列KFL液位指示调节仪的产品分类和参数、技术要求、试验条件和方法、检验规则、标志、包装及贮存。 本标准适用于KFL-2□型(扭管型)、KFL-3□型(阻尼型)浮筒式液位指示调节仪。

KF series pneumatic field instruments model.KFL level indicating controllers

ICS
25.040.40
CCS
N16
发布
1999-05-14
实施
1999-07-01

本标准规定了KF系列KFP型压力指示调节仪的产品分类和参数、技术要求、试验条件和方法、检验规则、标志、包装及贮存。 本标准适用于KFP-01(盘簧管)型,KFP-02(波纹管)型,KFP-03(标准信号)型压力指示调节仪。

KF series pneumatic field instruments model.KFT temperature indicating controllers

ICS
25.040.40
CCS
N16
发布
1999-05-14
实施
1999-07-01

本标准规定了KF系列KFT型温度指示调节仪的产品分类和参数、技术要求、试验条件和方法、检验规则、标志、包装及贮存。 本标准适用于KFT-06(充液式),KFT-07(充气式)温度指示调节仪。

KF series pneumatic field instruments model.KFP pressure indicating controllers

ICS
CCS
N16
发布
1999-05-14
实施
1999-07-01

本标准规定了KF系列KFD型差压指示调节仪的产品分类和参数、技术要求、试验条件和方法、检验规则、标志、包装及贮存。 本标准适用于KFD-11,KFD-22,KFD-33,KFD-44(标准型),KFD-6□(单法兰型),KFD-7□(双法兰型)和KFD-8□(高静压型)差压指示调节仪。

KF series pneumatic field instruments model.KFD differential pressure indicating controllers

ICS
25.040.40
CCS
N16
发布
1999-05-14
实施
1999-07-01

本标准规定了KF系列KFK型压力指示调节仪的产品分类和参数、技术要求、试验条件和方法、检验规则、标志、包装及贮存。 本标准适用于KFK-1□型,KFK-2□型和KFK-7□型压力指示调节仪。

KF series pneumatic field instruments model.KFK pressure indicating controllers

ICS
25.040.40
CCS
N16
发布
1999-05-14
实施
1999-07-01

This part of IEC 60534 includes equations for predicting the flow of compressible and incompressible fluids through control valves. The equations for incompressible flow are based on standard hydrodynamic equations for Newtonian incompressible fluids. They are not intended for use when non-Newtonian fluids, fluid mixtures, slurries, or liquid-solid conveyance systems are encountered. At very low ratios of pressure differential to absolute inlet pressure (△p/p1), compressible fluids behave similarly to incompressible fluids. Under such conditions, the sizing equations for compressible flow can be traced to the standard hydrodynamic equations for Newtonian incompressible fluids. However, increasing values of △p/p1 result in compressibility effects which require that the basic equations be modified by appropriate correction factors. The equations for compressible fluids are for use with gas or vapour and are not intended for use with multiphase streams such as gas-liquid, vapour-liquid or gas-solid mixtures. For compressible fluid applications, this part of IEC 60534 is valid for valves with xT ≤ 0,84 (see table 2). For valves with xT > 0,84 (e.g. some multistage valves), greater inaccuracy of flow prediction can be expected. Reasonable accuracy can only be maintained for control valves if Kv/d < 0,04 (Cv/d < 0,047).

Industrial-process control valves - Part 2-1: Flow capacity - Sizing equations for fluid flow under installed conditions

ICS
23.060.40
CCS
N16
发布
1998-09
实施
2011-04-01

La presente partie de la CEI 60534 specifie pour les classes de pressions et les dimensions nominales donnees, les dimensions bout a bout des vannes de regulation a soupape a deux voies, a corps droit avec embouts a souder pour les dimensions nominales DN 15 a DN 450. Le but de cette norme est d'aider les utilisateurs a configurer leurs tuyauteries en foumissant des dimensions normalisees de vannes de regulation a embouts a souder.

Industrial-process control valves - Part 3-3: Dimensions - End-to-end dimensions for buttweld, two-way, globe-type, straight pattern control valves

ICS
23.060.40
CCS
N16
发布
1998-08
实施
1998-08-18

General specification for artillery hydraulic governors

ICS
CCS
N16
发布
1998
实施

This section of IEC 60534-6 is intended to permit a variety of positioning devices, which respond to a linear motion, to be mounted on the actuator of a control valve, either directly or by employing an intermediate mounting bracket. This section is applicable where interchangeability between actuators and positioners is desired. The following parameters define the intended applicability of this section for the guidance of manufacturers and users. - The standardized mounting applies only to positioners which are mounted on the side of the actuator. - The standardized mounting applies in general only to actuators which have a travel from 10 mm through 100 mm. - The standardized mounting is designed to cover three basic types of actuator designs (see figure 1): a) those with some form of cast or fabricated yoke to connect the actuator power unit to the valve; b) those which use some form of central tube yoke to connect the actuator power unit to the valve; c) those in which the yoke incorporates two or more columns or pillars to connect the actuator power unit to the valve.

Industrial-process control valves - Part 6: Mounting details for attachment of positioners to control valves - Section 1: Positioner mounting on linear actuators

ICS
23.060.40
CCS
N16
发布
1997-08
实施
1997-09-19

Industrial-process control valves - Part 8: Noise considerations - Section 3: Control valve aerodynamic noise prediction method

ICS
17.140.20;23.060.40
CCS
N16
发布
1995-08
实施

本标准规定了工业过程控制系统用电磁阀的产品分类、技术要求、试验方法、检验规则等。 本标准适用于以清洁的液体、气体、蒸发为工作介质、在管路中实现开闭控制功能的电磁阀。 本标准不适用于以液压、气压作动力传动控制用的电磁换向阀。

Solenoid valves for industrial process control systems

ICS
25.040.40
CCS
N16
发布
1994-08-23
实施
1995-05-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved