共找到 337 条与 工程抗震 相关的标准,共 23 页
Earthquake Disaster Remote Sensing Evaluation of Building Damage
1:250 000 Seismic Tectonic Map Compilation for Active Fault Exploration
Technical specification for strong motion observation of building structures
This document specifies minimum requirements and test methods for elastomeric seismic isolators used for buildings and the rubber material used in the manufacture of such isolators. It is applicable to elastomeric seismic isolators used to provide buildings with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates. They are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.
Elastomeric seismic-protection isolators - Part 3: Applications for buildings - Specifications
This document specifies minimum requirements and test methods for elastomeric seismic isolators used for bridges, as well as rubber material used in the manufacture of such isolators. It is applicable to elastomeric seismic isolators used to provide bridges with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates, which are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.
Elastomeric seismic-protection isolators - Part 2: Applications for bridges - Specifications
This European Standard covers the design of devices that are provided in structures, with the aim of modifying their response to the seismic action. It specifies functional requirements and general design rules for the seismic situation, material characteristics, manufacturing and testing requirements, as well as evaluation of conformity, installation and maintenance requirements. This European Standard covers the types of devices and combinations thereof as defined in 3.4.NOTE Additional information concerning the scope of this European Standard is given in Annex A.
Anti-seismic devices; German version EN 15129:2018
Technical specification for hydraulic fracturing method and sleeve core release method for in-situ stress measurement
现批准《建筑隔震柔性管道》为建筑工业行业产品标准,编号为 JG/T541-2017,自2018年8月1日起实施。 本标准在住房城乡建设部门户网站(www.mohurd.gov.cn)公开,并由我部标准定额研究所组织中国标准出版社出版发行。 中华人民共和国住房和城乡建设部 2017年12月27日
Building isolation flexible pipes
Classification and codes of seismic satellite electromagnetic observation items
Active Fault Detection Remote Sensing Survey
Comprehensive Lightning Protection for Seismic Stations
本标准规定了地震预警等级、预警图标、预警声音、预警信息发布要求和演练预警信息发布要求。 本标准适用于地震预警信息的发布与传播。
Release of Earthquake Early Warning Information
本标准适用于山东省抗震设防烈度为7度 ~8度地区、建筑层数为1层 ~2层且单体建筑面积不超过 360㎡ 的一般农村房屋。
Anti-seismic Technical Standards for Rural Buildings
Bases for design of structures - Seismic actions on structures
City and County Earthquake Disaster Emergency Rescue Team Construction Requirements
本标准规定了建设工程强震动监测台阵的术语和定义、布设基本要求、监测系统组成和技术要求、监测台阵试运行、监测系统维护和记录要求。 本标准适用于四川省内建设工程强震动监测台阵的建设。
Technical requirements for strong vibration monitoring arrays for construction projects in Sichuan Province
Earthquake Cataloging Specification
Strong Motion Observation Technical Regulations
1:50 000 active fault mapping database specification
Technical specification for seismic strengthening of buildings
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号