共找到 81 条与 特种玻璃 相关的标准,共 6 页
1.1 This specification covers the requirements for circular, fully tempered, high clarity, flat glasses used for portlight applications. 1.2 The dimensional values stated in English units are to be regarded as standard. The values given in parentheses are for information only. 1.3 The following safety hazard caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.
Standard Specification for Glasses, Portlight, Circular, Fully Tempered
1.1 This specification covers the requirements for circular, fully tempered, high clarity, flat glasses used for portlight applications. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 The following safety hazard caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Specification for Glasses, Portlight, Circular, Fully Tempered
1.1 This specification covers the requirements for circular, fully tempered, high clarity, flat glasses used for portlight applications. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 The following safety hazard caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Specification for Glasses, Portlight, Circular, Fully Tempered
1.1 This specification covers the requirements for circular, fully tempered, high clarity, flat glasses used for portlight applications. 1.2 The dimensional values stated in English units are to be regarded as standard. The values given in parentheses are for information only. 1.3 The following safety hazard caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.
Standard Specification for Glasses, Portlight, Circular, Fully Tempered
This amendment forms a part of MIL-G-5485D, dated 22 February 1993, and is approved for use bya ll Departments and Agencieso f the Department of Defense.
GLASS, LAMINATED, FLAT, BULLET RESISTANT
1.1 These test methods, including a fire test response method, cover the apparatus, procedures, and acceptance conditions for evaluating the normal operational performance and the performance characteristics under assault conditions of detention glazing used in window and door assemblies in detention and correctional facilities; thus, these test methods only give an indication of the performance characteristics of detention glazing in actual service. Such variables as installation and maintenance conditions are not considered except as otherwise included in this test method.1.2 It is the intent of these test methods to help ensure that detention glazing performs at or above minimum acceptable levels to restrict inmate passage to unauthorized areas, to confine inmates, to delay and frustrate escape attempts and to resist vandalism.1.3 Tools defined in these test methods are representative of similar tools or materials, which may become available to inmates within the secure perimeter of detention and correctional facilities, and which could be used to inflict similar product damage.1.4 These test methods should not be used to establish or confirm the absolute prevention of forced entries or exits. These test methods define five factors (tool, temperature, techniques, time, and number of impacts) used to determine resistance to defined attacks.1.5 The values stated in inch-pound units are to be regarded as the standard. The SI values in stated parentheses are for information only.1.6 In these test methods, the specimens are subjected to one or more specific sets of laboratory test conditions. If different test conditions are substituted or the end-use conditions are changed, it is not always possible by or from these test methods to predict changes in the physical attack, or fire-test-response characteristics measured, or both; therefore, the results are valid only for the physical attack, or fire-test-exposure conditions, or both, described in these test methods.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Test Methods for Glazing for Detention Facilities
本标准规定了航空有机玻璃长期吸水率试验方法的原理、仪器、试样、试验程序和试验结果等。 本标准适用于厚度等于或大于3mm的航空有机玻璃板材。
Test method for long-term water absorption of aviation plexiglass
This standard specifies glass tubes used on chemical analysis.
Glass tubes
Pressure resistant circular glass-to-metal used sight glasses - Part 1: For holders with recess; design, glass in material No. 1.4462
Pressure resistant circular glass-to-metal fused sight glasses - Part 1: For holders with recess; design steel; operating temperatures -30 °C and -60 °C
This Part of BS AU 209 specifies the minimum requirements for the performance of security glazing and its installation in order to deter unauthorized entry into, or use of, passenger cars and car derived vehicles. Provisions for security glazing are covered in annex A.
Vehicle security - Specification for security glazing for passenger cars and car derived vehicles
Thispecification c o v e r s the r e q u i r e m e n t s for b u l l e t r e s i s t a n t g l a s s inaircraft w i n d s c r e e n a n d o the r s i m i l a r a p p l i c a t i o n
GLASS, LAMINATED, FLAT, BULLET RESISTANT
Specifies requirements for safety glass for installation as windscreens, other windows or as partitions in motor vehicles and trailers. Includes tests. This edition aligns with ECE Regulation 43.
Specification for road vehicle safety glass
Specification for Barium sodium potassium glass for military electronic devices and components
この規格は,X線防護のために用いるX線防護用船ガラス(以下,鉄ガラスという。)について規定する。
Lead glass for X-ray protection
Plastic Safety Glazing Sheets
Plastic Safety Glazing Sheets
Performance requirements and procedures for type testing for glazing resistant to five levels of attack by hand-held guns firing bullets and one level of attack by shotgun. For use at temperatures between 10C and 30C. Essential information for installation is also given.
Bullet-resistant glazing. Specification for glazing for interior use
Glass, Light and Heat Reflecting
Verre Reflecteur De Lumiere Et De Chaleur Modificatif No 1 Avril 1977
This specification covers the requirements for one type
GLASS, DARK ADAPTATION
This specification covers requirements for lighting wedges and cover glasses for use in integrally lighted and unlighted aircraft instruments.
GLASS, AIRCRAFT INSTRUMENT, LIGHTING WEDGE AND COVER
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved