共找到 88 条与 消防设备 相关的标准,共 6 页
Ships and marine technology - Fire-extinguishing systems for protection of galley cooking equipment
Defines procedures to achieve a practical degree of fire protection, specifies portable firefighting equipment and sets requirements for fixed fire-fighting systems. Applies to small craft of all types with a hull length, LH, greater than 15 m and up to
Small craft - Fire protection Part 2: Craft with a hull length of over 15 m
Defines procedures to achieve a practical degree of fire protection, specifies portable fire-fighting equipment and sets requirements for fixed fire-fighting systems. Applies to small craft of all types with a hull length, LH, not exceeding 15 m. Does no
Small craft - Fire protection Part 1: Craft with a hull length of up to and including 15 m
本规范规定了潜艇用预作用喷水灭火系统(以下简称预作用系统)的要求、质量保证规定、交货准备等。 本规范适用于潜艇用预作用系统的设计和验收。
Specification for preaction system of submarine
GUIDANCE NOTES ON FIRE-FIGHTING SYSTEMS
GUIDANCE NOTES ON FIRE-FIGHTING SYSTEMS
Ships and marine technology - Shipboard plans for fire protection, life-saving appliances and means of escape; Technical Corrigendum 1
These test methods are intended to provide a basis for evaluating the time period during which bulkheads and decks will continue to perform its intended function when subjected to a controlled, standardized fire exposure. 5.1.1 In particular, the selected standard exposure condition simulates the condition of total continuous engulfment of a member or assembly in the luminous flame (fire plume) area of a large free-burning fluid hydrocarbon pool fire. The standard fire exposure is basically defined in terms of the total flux incident on the test specimen together with appropriate temperature conditions. 5.1.2 It is recognized that the thermodynamic properties of free-burning, hydrocarbon fluid pool fires have not been completely characterized and are variable depending on the conditions, the physical relationship of the structural member to the exposing fire, and other factors. As a result, the exposure specified in these test methods is not necessarily representative of all the conditions that exist in large hydrocarbon pool fires. The specified standard exposure is based upon the best available information and testing technology. It provides a basis for comparing the relative performance of different assemblies under controlled conditions. 5.1.3 It is feasible that substantial changes in the fire performance characteristics of the assembly will result from any variation from the construction or conditions (that is, size, method of assembly, and materials) that are tested. The structural assemblies that will be evaluated in accordance with these test methods will be located on a ship.1.1 These test methods described in this fire-test response standard are used for determining the fire-test response of insulated marine steel bulkheads and decks. The insulation is either homogeneous or composite construction.1.2 It is the intent that tests conducted in accordance with these test methods will indicate whether bulkheads and decks will continue to perform their intended function during the period of fire exposure. These test methods shall not be construed as implying suitability for use after fire exposure.1.3 These test methods prescribe a standard fire exposure for comparing the relative performance of different bulkhead and deck assemblies under controlled laboratory conditions. The application of these test results to predict the performance of actual assemblies when exposed to large pool fires requires a careful engineering evaluation.1.4 Limitations - These test methods do not provide the following:1.4.1 Full information on the performance of assemblies constructed with components or of dimensions other than those tested.1.4.2 An evaluation of the degree to which the assembly contributes to the fire hazard through the generation of smoke, toxic gases, or other products of combustion.1.4.3 Measurement of flame spread over the surface of the test assembly.1.4.4 The erosive effect that the velocities or turbulence, or both, generated in large pool fires has on some fire protection materials.1.4.5 Full information on the performance of assemblies at times less than 5 min because the rise time called out in Section is longer than that of a real fire.1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for approximate information only.1.6 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire-risk assessment of the materials, products, or assemblies under actual fire conditions.1.7 This test method is based on the fire exposure as defined in Test Methods E 1529 (issued by the Committee on Fire Standards, E05).This standard does not ......
Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Insulated Marine Bulkheads and Decks, Constructed of Steel
1.1 These test methods described in this fire-test response standard are used for determining the fire-test response of insulated marine steel bulkheads and decks. The insulation is either homogeneous or composite construction.1.2 It is the intent that tests conducted in accordance with these test methods will indicate whether bulkheads and decks will continue to perform their intended function during the period of fire exposure. These test methods shall not be construed as implying suitability for use after fire exposure.1.3 These test methods prescribe a standard fire exposure for comparing the relative performance of different bulkhead and deck assemblies under controlled laboratory conditions. The application of these test results to predict the performance of actual assemblies when exposed to large pool fires requires a careful engineering evaluation.1.4 Limitations8212;These test methods do not provide the following:1.4.1 Full information on the performance of assemblies constructed with components or of dimensions other than those tested.1.4.2 An evaluation of the degree to which the assembly contributes to the fire hazard through the generation of smoke, toxic gases, or other products of combustion.1.4.3 Measurement of flame spread over the surface of the test assembly.1.4.4 The erosive effect that the velocities or turbulence, or both, generated in large pool fires has on some fire protection materials.1.4.5 Full information on the performance of assemblies at times less than 5 min because the rise time called out in Section is longer than that of a real fire.1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for approximate information only.1.6 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire-risk assessment of the materials, products, or assemblies under actual fire conditions.1.7 This test method is based on the fire exposure as defined in Test Methods E 1529 (issued by the Committee on Fire Standards, E05).1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Insulated Marine Bulkheads and Decks, Constructed of Steel
本标准规定了船用二氧化碳灭火装置的组成、部件分类、技术要求、试验方法、检验规则、标志、包装、运输和贮存。 本标准适用于船用二氧化碳气体灭火系统。
Marine carbon dioxide fire extinguishing plant
This guide covers the selection, installation, maintenance, and testing of shipboard fire detection systems other than sprinkler systems. This guide is intended for use by all persons planning, designing, installing, or using fire alarm systems onboard vessels. As it includes regulatory requirements, this guide addresses those vessels subject to regulations and ship classification rules. However, the principles stated herein are also suitable for unregulated commercial vessels, pleasure craft, military vessels, and similar vessels that are not required to meet regulations for fire detection and alarm systems. Limitations - This guide does not constitute regulations or ship classification rules, which must be consulted when applicable. The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Guide for Shipboard Fire Detection Systems
本标准规定船舶消防属具的分类、技术要求、试验方法、检验规则及标志。 本标准适用于各类船舶上配置的消防用品的盛放和固定。
Ship fire fighting equipment
Shipbuilding. Fire station.
Shipbuilding. Fire pipework. Connector with international fitting (ship side).
SHIPBUILDING. FIRE HOSES. FIRE VALVES.
本标准规定发泡倍数不大于12的船用低倍泡沫装置的组成,技术条件、试验方法、检验规则、标志、运输、贮存等要求。 本标准适用于船舶及海上石油平台消防系统所选用的装置。
Marine low expansion foam device
本标准规定了连板密封面尺寸符合GB569、GB2501的油舱空气管防火网的产品分类,技术要求、检验规则、标志和包装。 本标准适用于油舱空气管路。
Oil tank air pipe fire screen
本标准规定了船用自动喷水灭火装置的分类、技术要求、试验方法、检验规则以及标志、包装、运输和贮存。 本标准适用于船舶、海上石油平台湿式自动喷水灭火装置和雨淋自动喷水灭火装置。
Marine sprinkler system
1.1 This guide covers the selection, installation, maintenance, and testing of shipboard fire detection systems other than sprinkler systems. 1.2 This guide is intended for use by all persons planning, designing, installing or utilizing fire alarm systems onboard vessels. As it includes regulatory requirements, this guide addresses those vessels subject to regulations and ship classification rules. However, the principles stated herein are also suitable for unregulated commercial vessels, pleasure craft, military vessels, and similar vessels that are not required to meet regulations for fire detection and alarm systems. 1.3 Limitations -This guide does not constitute regulations or ship classification rules, which must be consulted when applicable. 1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Guide for Shipboard Fire Detection Systems
1.1 This guide covers the selection, installation, maintenance, and testing of shipboard fire detection systems other than sprinkler systems. 1.2 This guide is intended for use by all persons planning, designing, installing or utilizing fire alarm systems onboard vessels. As it includes regulatory requirements, this guide addresses those vessels subject to regulations and ship classification rules. However, the principles stated herein are also suitable for unregulated commercial vessels, pleasure craft, military vessels, and similar vessels that are not required to meet regulations for fire detection and alarm systems. 1.3 Limitations -This guide does not constitute regulations or ship classification rules, which must be consulted when applicable. 1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Guide for Shipboard Fire Detection Systems