91.060.50;91.190 标准查询与下载



共找到 18 条与 相关的标准,共 2

UL Standard for Safety Panic Hardware (Sixth Edition; Reprint with Revisions Through and Including March 22, 2017)

ICS
91.060.50;91.190
CCS
Y71
发布
2017-3-22
实施
0000-00-00

Auxiliary Hardware

ICS
91.060.50;91.190
CCS
Y71
发布
2013-01-01
实施

Editorial Revisions for Clarity, Addition of a Glossary, Clarification of Test Methods

Standard for Safety for Panic Hardware

ICS
91.060.50;91.190
CCS
Y73
发布
2012
实施

Locks, latches, mechanisms cylinder. Methods and testing

ICS
91.060.50;91.190
CCS
发布
2012
实施
2014-01-01

Standard for Safety for Panic Hardware

ICS
91.060.50;91.190
CCS
Y71
发布
2012
实施

This European Standard specifies requirements, methods of test and performance criteria against which the compatibility of components and their performance can be assessed when used in combination to form an electrically controlled hold-open system. It also specifies requirements for the integrity of such hold-open systems when connected to fire detection and fire alarm systems or other systems, including the signal exchange and technical data for interfaces. This European Standard provides requirements for the application of electrically controlled hold-open systems used for fire/smoke doors in buildings, where such doors are required to be self-closing. It covers planning, design (see Annex A), installation (see Annex B), commissioning, use and maintenance (see Annex E) of hold-open systems, intended for the protection of life and/or the protection of property. This may also include hold-open systems, or components of the hold-open system, that are self-contained in a single enclosure. Electrically controlled hold-open systems manufactured, installed and serviced in accordance with this European Standard are recommended for use wherever there is a requirement for reliable hold-open and release of an individual self-closing fire/smoke door assembly in the case of fire. The use of hold-open systems for closures in conveyor systems conforming to EN 1366-7, which applies in conjunction with EN 1363-1, may require additional proof of suitability, which is not covered by this European Standard. This European Standard does not cover design, installation, commissioning, use and maintenance of building fire detection and fire alarm systems (covered by CEN/TS 54-14) but does cover the connection of hold-open systems conforming to this European Standard to building fire detection and fire alarm systems, under certain prescribed conditions. This European Standard does not cover the requirements of performance characteristics and operational environment conditions of particular components of a hold-open system, where these requirements are already covered by European specifications, and which include appropriate test methods to assure reproducible test results for the product conformity assessment. These European Standards are referred to in Clause 5. This European Standard does not cover electrically controlled systems used for smoke venting purposes or systems that allow the door to remain open under fault conditions (i.e. not fail-safe). This European Standard does not cover electrically controlled hold-open systems that are not connected to main power supply and are battery powered only.

Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance

ICS
91.060.50;91.190
CCS
Y71
发布
2008-03-31
实施
2008-03-31

This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquid chilling packages with electrical driven compressors are fit for the use designated by the manufacturer when used for space heating and/or cooling. This European Standard applies to factory-made units that can be ducted. This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers. This standard applies to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard. In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser. O This standard is primarily intended for water and brine chilling packages but can be used for cooling any other liquid subject to agreement. This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side. The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard. This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant. Installations used for heating and/or cooling of industrial processes are not within the scope of this standard. NOTE Part load testing of units is dealt with in CEN/TS 14825.

Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance;English version of DIN EN 14637:2008-01

ICS
91.060.50;91.190
CCS
Y71
发布
2008-01
实施

This standard establishes requirements for exit devices and trim, automatic and self-latching flush bolts, removable mullions, coordinators, and carry-open bars. Performance criteria include cycle, operational, strength, material evaluation, and finish tests. Functions and types are described and numbered.

Exit Devices

ICS
91.060.50;91.190
CCS
Y71
发布
2008
实施

This Draft for Development specifies performance requirements for materials used in gaskets, co-extruded glazing gaskets, weatherstripping and cellular adhesive glazing tapes for use in windows, doors, conservatories and curtain walling, made from any material, primarily for domestic and residential use. It is not applicable to butyl glazing tapes and other mastic materials, or to any materials for use in shutters. NOTE 1 Guidance on selection of appropriate grades of products from those listed in BS EN 12365-1:2003 is given in Annex A. NOTE 2 Guidance on testing for wear resistance, resistance to chemicals and induction of environmental stress cracking is given in Annex B.

Materials for gaskets and weatherstripping for windows, doors, conservatories and curtain walling – Requirements and test methods

ICS
91.060.50;91.190
CCS
发布
2007-02-28
实施

This Draft for Development specifies performance requirements for materials used in gaskets, co-extruded glazing gaskets, weatherstripping and cellular adhesive glazing tapes for use in windows, doors, conservatories and curtain walling, made from any material, primarily for domestic and residential use. It is not applicable to butyl glazing tapes and other mastic materials, or to any materials for use in shutters. NOTE 1 Guidance on selection of appropriate grades of products from those listed in BS EN 12365-1:2003 is given in Annex A. NOTE 2 Guidance on testing for wear resistance, resistance to chemicals and induction of environmental stress cracking is given in Annex B.

Materials for gaskets and weatherstripping for windows, doors, conservatories and curtain walling - Requirements and test methods

ICS
91.060.50;91.190
CCS
Q70;Q17
发布
2007-02-28
实施
2007-02-28

This European Standard specifies requirements, methods of test and performance criteria against which the compatibility of components and their performance can be assessed when used in combination to form an electrically controlled hold-open system. It also specifies requirements for the integrity of such hold-open systems when connected to fire detection and fire alarm systems or other systems, including the signal exchange and technical data for interfaces.This European Standard provides requirements for the application of electrically controlled hold-open systems used for fire/smoke doors in buildings, where such doors are required to be self-closing. It covers planning, design (see Annex A), installation (see Annex B), commissioning, use and maintenance (see Annex E) of hold-open systems, intended for the protection of life and/or the protection of property.This may also include hold-open systems, or components of the hold-open system, that are self-contained in a single enclosure. Electrically controlled hold-open systems manufactured, installed and serviced in accordance withThis European Standard are recommended for use wherever there is a requirement for reliable hold-open and release of an individual self-closing fire/smoke door assembly in the case of fire. The use of hold-open systems for closures in conveyor systems conforming to EN 1366-7, which applies in conjunction with EN 1363-1, may require additional proof of suitability, which is not covered byThis European Standard.This European Standard does not cover design, installation, commissioning, use and maintenance of building fire detection and fire alarm systems (covered by CEN/TS 54-14) but does cover the connection of hold-open systems conforming toThis European Standard to building fire detection and fire alarm systems, under certain prescribed conditions.This European Standard does not cover the requirements of performance characteristics and operational environment conditions of particular components of a hold-open system, where these requirements are already covered by European specifications, and which include appropriate test methods to assure reproducible test results for the product conformity assessment. These European Standards are referred to in Clause 5.This European Standard does not cover electrically controlled systems used for smoke venting purposes or systems that allow the door to remain open under fault conditions (i.e. not fail-safe).This European Standard does not cover electrically controlled hold-open systems that are not connected to main power supply and are battery powered only.

Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance

ICS
91.060.50;91.190
CCS
发布
2007
实施

Operating forces - Test method - Part 1 : windows.

ICS
91.060.50;91.190
CCS
P32
发布
2004-06-01
实施
2004-06-05

This European Standard specifies the performance reuirements of gaskets and weatherstripping for the control of the passage of air,water,noise and energy betwween openable and fixed parts of doors,windows,shutters and curtain walling.

Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 1: Performance requirements and classification

ICS
91.060.50;91.190
CCS
发布
2003-09-01
实施

This European Standard specifies the method to be used to select, prepare condition and test sample of gaskets or weatherstripping, to determineThe force required to compress or deflectThem by a predetermined amount toTheir minimum working width, underThe conditions laid down forThe test.

Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 2: Linear compression force test methods

ICS
91.060.50;91.190
CCS
发布
2003-09-01
实施

This European Standard specifies the test method for determiningThe force required when engaging or releasingThe hardware of a window and when commencingThe movement of a casement or sash, in both opening and closing directions.It is applicable to manually operated windows.This European Standard is applicable to products of any materials.

Operating forces - Test method - Part 1: Windows

ICS
91.060.50;91.190
CCS
发布
2003
实施

Establishes requirements for various types of auxiliary hardware and includes performance tests covering operational, cyclical, strength or finish criteria. A type numbering system is also provided.

Auxiliary Hardware

ICS
91.060.50;91.190
CCS
L63
发布
2002
实施

Establishes requirements for exit devices and trim, automatic and self-latching flush bolts, removable mullions, coordinators, and carry-open bars. Performance criteria include cycle, operational, strength, material evaluation, and finish tests. Functions and types are described and numbered.

Exit Devices

ICS
91.060.50;91.190
CCS
A91
发布
2001
实施

Proposes requirements for the design, and test methods for, drive units, leaves and components of powered pedestrian doors, including constructions that are operated electro-mechanically, electro-hydraulically or pneumatically.

Powered doors for pedestrian access and egress

ICS
91.060.50;91.190
CCS
发布
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved